12
Installing the Touch Panel
Color Passive-Matrix LCD Touch Panels
6.
Disconnect the AXlink connector from the AMX Control System that supplies
power and data to the touch panel. Then, disconnect the optional RS-232
connector from the external RS-232 device connected to the touch panel.
7.
Thread the incoming AXlink and RS-232 wiring through the BB-TP2 knockout.
8.
Fasten the BB-TP2 to the plasterboard using the expansion screws supplied with
the enclosure.
9.
Connect the AXlink and RS-232 wiring to the touch panel. Refer to
Wiring the
Touch Panel
for complete wiring information.
10.
Fasten the touch panel to the BB-TP2 with the #6-32 screws supplied with the
enclosure.
11.
Insert the engraved overlay back into the bezel.
12.
Connect the AXlink wiring to the AMX Control System and RS-232 wiring to the
external RS-232 device. The touch panel will beep when you apply power.
AXM-CP or AXM-CP/PB (rack mount)
Mount the rack mount touch panel ( Figure 10) into an equipment rack:
1.
Thread the incoming AXlink and RS-232 (optional) wiring through the opening
in the equipment rack.
2.
Disconnect the AXlink connector from the AMX Control System that supplies
power and data to the touch panel. Then, disconnect the optional RS-232
connector from the external RS-232 device connected to the touch panel.
Note
The touch panel must always
be installed with the release
slot located at the bottom.
Figure 10
AXM-CP/PB rack mount
Содержание AXM-CP
Страница 8: ...vi Table of Contents Color Passive Matrix LCD Touch Panels...
Страница 26: ...18 Installing the Touch Panel Color Passive Matrix LCD Touch Panels...
Страница 134: ...126 AXCESS Programming Color Passive Matrix LCD Touch Panels...
Страница 142: ...134 Memory Upgrade Color Passive Matrix LCD Touch Panels...
Страница 150: ...142 Specifications Color Passive Matrix LCD Touch Panels...
Страница 152: ...144 Technical Support Color Passive Matrix LCD Touch Panels...