Replacing the Battery
48
6" Color Video Wall Panel
5.
Place the touch panel facedown onto a soft cloth and begin unscrewing the four screws
securing the housing to the main unit. Refer to FIG. 4 on page 5 for more information.
6.
Remove the touch overlay’s ribbon cable connectors from the circuit card.
7.
Remove the upper circuit card and turn it over.
8.
Carefully pry the battery out of its socket and insert the new battery.
9.
Replace the circuit card and insert/tighten the circuit card spacers.
10.
Connect the touch overlay’s ribbon cable connector to the circuit card.
11.
Re-insert and tighten the housing screws to its four locations along the outside of the housing
box.
12.
Return the touch panel to the backbox or equipment rack and connect the AXlink connector.
13.
Insert the four mounting screws/two expansion clips, and tighten.
14.
Put the magnetic faceplate back onto the main unit and verify that it is secure.