Linking Multiple SBCs

Note:  Each enclosure supports 32 SBCs (or a total of 32 XNNet compatible devices, 
such as remote control panels and status displays).
SBCs can be linked together in a daisy chain to create multiple control points for a 
single system. XNNet link cables can be attached to either Comm Link connector
(P4 or P5). The total distance of the cable runs cannot exceed 1,000 ft. (304.8 m).

To link SBCs:

1.

Connect the first SBC to the router using one of the Comm Links (P4 or P5; 
see Step 10 previous page).

2.

Attach an XNNet link cable to the SBC’s other Comm Link, following the same 
procedure used when connecting to the router.

3.

Attach the other end of the XNNet cable to a Comm Link on the second SBC.

4.

Repeat Steps 2 and 3 for any additional SBCs.

5.

If required* terminate the final SBC. Loosen the two outer screws, insert a 
120 ohm resistor (customer supplied) in the outer contacts, and tighten the 
screws (FIG 3).

*On large control networks, termination may be required on the last linked SBC. 

Operation

If the SBC was not ordered with factory programing or if the settings need to be 
changed, use the following procedures to set the destination ID and to change the 
virtual matrix.

Setting the Destination ID

The destination ID specifies which output the SBC is controlling. SBCs are assigned 
to a virtual output (e.g., RGB), not a physical output (e.g., R).

To set the destination ID:
3-Key SBC

1.

Hold down the x10 key for five seconds until the display screen starts flashing.

2.

Scroll to the correct destination ID using the “+” or “-” key.

3.

If necessary, change the virtual matrix (see “Changing the Virtual Matrix” 
section below, starting with Step 2).

4.

Wait until the flashing stops (approx. five seconds) before operating.

12-Key SBC

1.

Hold down the “0” key for five seconds until the display screen starts flashing.

2.

Enter the destination ID or scroll to correct destination using the “+” or “-” key.

3.

If necessary, change the virtual matrix (see “Changing the Virtual Matrix”  
section below, starting with Step 2).

4.

Wait until the flashing stops (approx. five seconds) before operating.

Changing the Virtual Matrix

The virtual matrix determines which signals switch together, e.g., audio follow video 
(often the default), video only, or audio only. See system documentation for more 
information on virtual matrices.

To change the virtual matrix:
3-Key SBC

1.

Hold down x10 key for five seconds until screen starts flashing; then release.

2.

Hold down x10 key for five more seconds until screen starts flaring 
(i.e., characters briefly brighten, then repetitively dim to normal. Display never 
goes blank). The screen displays current virtual matrix number.

3.

Scroll to desired virtual matrix number using “+” or “-” key.

4.

Wait until the flaring stops (approx. five seconds) before setting destination ID.

12-Key SBC

1.

Hold down “0” key for five seconds until screen starts flashing; then release.

2.

Hold down “0” key for five more seconds until screen starts flaring 
(e.g., characters briefly brighten, then repetitively dim to normal. Display never 
goes blank). The screen displays the current virtual matrix number.

3.

Enter desired virtual matrix number or scroll to it using the “+” or “-” key.

4.

Wait until flaring stops (approx. five seconds) before setting destination ID.

Executing Switches & LED Display

The scrolling range for valid source numbers is from 1 to the maximum number of 
inputs configured in the virtual matrix. If you hold down the “+” key on the 3-Key SBC, 
the display will scroll all numbers in sequence up to 99 even if those numbers are not 
associated with a source. After the “+” key is released the LED will briefly display the 
last number scrolled. If the number is invalid (e.g., number 52 on a system with 32 
sources), the SBC will revert to the last valid source number in the sequence. For the 
12-Key SBC, entering an invalid number will result in the LED displaying an error 
code (see table at bottom of this column).
When the system is powered up, the LED on the SBC briefly flashes the assigned 
destination number.

To operate the 3-Key SBC: 

Press the keys according to their function as indicated.

Scroll to “00” to disconnect all source signals from the 
destination device.

To operate the 12-Key SBC:

Press the keys according to their function as indicated. 
To enter a two or three digit number, press the next number 
within two (2) seconds of pressing the previous number.

Enter “00” to disconnect all source signals from the destination device.

Error Codes / Troubleshooting

Cleaning

SBCs require only topical cleaning. Use a dry cloth and mild glass cleaner to clean 
the surface of the SBC. Do not use abrasive cleaners to clean the faceplate.

FIG. 4  

Linking SBCs in a daisy-chain

2-digit SBCs linked

3-digit SBCs linked

Termination may be
required (see Step 5)

Keys

Function

+

Increases source signal selection by one

-

Decreases source signal selection by one

x10

Changes source signal selection in 
increments of 10
(hold down while pressing “+” or “-” )

Keys

Function

Number

Allows direct switching to a different source 
signal without scrolling

+

Increases source signal by one

-

Decreases source signal by one

Code

Causes

Actions

E1
Request Timed Out

Control Overrun – commands 
sent too quickly

Problem with physical connection 
to system

Re-enter commands

Check cable connections

Ensure virtual matrix 
number setting is valid

E2 
Virtual Matrix Error

Configuration problem

Ensure destination 
number is valid

E3 
Display Error

Valid source number cannot be 
displayed because it is higher 
than 99 on a 2-digit display, or 
999 on a 3-digit display

Enter valid source 
number

E4
Fragmented

A breakaway switch caused 
status mismatch between one or 
more components in a grouping

Check status on different 
levels using another 
control method to find 
status mismatch; reroute 
switch

SB03

+

-