![AMSEC SafeWizard Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/amsec/safewizard/safewizard_operating-instructions-manual_2936224031.webp)
SafeWizard
Operating Instructions
American Security Products Company
Last Revision 10/17/2008
Page 31 of 73
Document 4305199
Chapter 3-2-1-1
Access Control-
Door Access-
Time Delay Doors
This feature is used to delay the opening of a safe door. The purpose of this feature is to act as robbery
deterrent, by forcing the would-be robber to wait a specified amount of time, before the safe will open.
Normally, under the pressure of the clock the prospective robber will flee before the safe opens.
3-2-1-1.1 Door Access Control Menu
Door Access Control
1 Time Delay Doors
2 Time Delay Settings
3 Timelock Settings
4 Immediate Lock
5 Dual Control
From the Door Access Control Menu, select 1 for Time Delay Doors.
The standard “Manager User Profile” cannot access any of these screens, because the deterrent factor
would be eliminated; the manager could then disable the time delay to open the safe for the robber.
3-2-1-1.2 Time Delay Doors Screen
Time Delay for
Door 1
TDL Enabled Y
Delay Period (min)010
Open Period (min) 05
NEXT-BACK Door
QUIT To Continue
Door: This indicates the door number that the following settings are
valid for.
TDL Enabled: This indicates whether TDL is enabled or disabled for
the specified door. “Y” indicates enabled; “N” indicated disabled.
Delay Period: This indicates the delay period for the door listed.
Open Period: This indicates the amount of time this door can be
open, before going in to alarm.
According to the information above, in order to open door 1, an authorized user would have to wait 10
minuets, re-login, and would have 5 minuets to close the door.