background image

American Security Products Co.  

ESL20XL Operating Instructions 

Released Aug. 9, 2018 

Revision A

 

Page 1 of 10 

 

ESL20XL Electronic Lock Operating Instructions 

The ESL20XL uses a fixed length 6-digit combination. Your AMSEC ESL20XL Electronic Safe Lock has a default 
factory combination of: 1-2-3-4-5-6. 

Opening Your ESL20XL Lock for the First Time

 

1.

 

Press the “C” key. 

2.

 

Key in the factory preset combination. 

3.

 

Press the “#” key. 

If the combination was entered correctly, the lock will cycle open for three seconds. During this 3-second period, 
turn the handle of the safe to the unlocked position and pull the door open. 

Changing the ESL20XL Master User Combination 

You may change your combination any time you’d like and as many times as you’d like. To insure security once 

your safe is installed, you must change the factory preset combination to a new 6-digit combination.  
 

CAUTION:

 Combination changes should always be done with the door OPEN to prevent accidental lockout. 

1.

 

Press the “C” key. 

2.

 

Press the “#” key. You should hear a short warbling tone and see the red LED flash. 

3.

 

Key in your old 6-digit combination. 

4.

 

Press the “#” key. You should hear a short good combination tone. 

5.

 

Key in your new 6-digit combination. 

6.

 

Press the “#” key. You should hear a short good combination tone. 

7.

 

Re-key in the new 6-digit combination again. 

8.

 

Press the “#” key. If the combination input matches the first pass, you should hear a long good combination 

tone indicating your new combination has been recorded. 

9.

 

Test your new combination several times prior to closing and locking the safe. 

Note:  

 

See the ESL20XL Beep and LED Patterns table on Page 10. 

 

See 

Changing User Combinations

 section for instructions on changing combinations for Users other 

than the Master User. 

 
A Few Things to Remember

 

 

With each keystroke, the red LED on the keypad will flash and the beeper will chirp. 

 

If 4 incorrect combinations are entered, the lock will go into Penalty Lockout for 15 minutes to prevent 
trial-and-error attempts at opening the lock. The red LED will flash once every 5 seconds during this period. 

If you press any key during the Penalty Lockout Period, the red LED will flash and you will hear 8 rapid 

chirps. Removing power does not reset the Penalty Lockout.  

 

Before keying the combination, be sure that the handle of the safe is centered in the locked position to 
allow the lock to open freely. 

 

If the lock fails to open or acts strangely, replace the batteries with fresh alkaline 9-volt batteries. See 

Replacing the Batteries” on Page 2 of these instructions. It is a good practice to replace your batteries 

once a year to prevent corrosion damage from leakage and assure you always have ample power to open 

the lock. 

Содержание ESL20XL

Страница 1: ...hort good combination tone 7 Re key in the new 6 digit combination again 8 Press the key If the combination input matches the first pass you should hear a long good combination tone indicating your new combination has been recorded 9 Test your new combination several times prior to closing and locking the safe Note See the ESL20XL Beep and LED Patterns table on Page 10 See Changing User Combinatio...

Страница 2: ...s from the end of the batteries making sure you don t pull on the wires and disconnect the battery clip from the PC board 5 Snap on two new 9 volt batteries onto the clips making sure they are tight with no loose contacts 6 Press the two batteries back into their pockets taking care to route the wires in the open cavity so they are not positioned where they will get pinched under the batteries whe...

Страница 3: ...e Enabled F10 o The Master User or Manager is the only User with Administration capabilities o In Multi User mode there is no need for all Users to share the same combination as is the case with a mechanical combination lock o This feature allows the supervisor the ability to control the subordinate Users individually and makes employee turnover easier to manage because individual Users can be add...

Страница 4: ...osure is the same as if someone had pushed a panic button to summon help By signaling secretly at the safe the User doesn t risk angering the robber and risking possible personal injury External Control This feature allows the ESL20XL to be disabled and enabled by an auxiliary device like an Access Manager a Key Switch external Alarm System or any other external switching method o This feature mus...

Страница 5: ...The ESL20XL s advanced features are controlled only by the Master User and are set using Function Codes A function can be turned on and off or set using the Function Code with the Master User code as authorization for changing or setting the function A Function Code is a 2 digit code that is associated to a particular setting Each Function Code has a default or standard setting which is in the loc...

Страница 6: ... 01 02 03 o To Enable Time Delay C 01 Master Code 1 o To Disable Time Delay C 01 Master Code 0 o To set the Delay Period C 02 Master Code Delay Period 1 99 minutes o To set the Open Period C 03 Master Code Open Period 1 9 minutes Multiple User Settings Functions 10 11 12 13 o To Enable Multiple User Mode C 10 Master Code 1 o To Disable Multiple User Mode C 10 Master Code 0 o To Add or Enable a Sub...

Страница 7: ...Enable Armored Car TDL Bypass C 40 Master Code 1 Note Enabling Armored Car Bypass turns on enables User 9 which is the Armored Car User The User 9 combo must be set before this feature will function See Section 4 for changing instructions o To Disable Armored Car TDL Bypass C 40 Master Code 0 o To Enable Subordinate Authorizing User Armored Car TDL Bypass C 41 Master Code 1 o To Disable Subordinat...

Страница 8: ...larm output will be caused any time the Duress code is entered by any User during opening or starting of Time Delay Requires Expansion Module o Enabling Dual Combo Mode automatically adds a User 1 even if Multi User Mode is disabled Don t forget to set a Code for User 1 or there will not be two codes to open the lock Record Keeping To track Function Settings use this table Date F Function Descript...

Страница 9: ... lock inside the door The ESL20XL relies on a solenoid to actuate this bolt That solenoid can only overcome so much resistance and if that resistance is too great the bolt does not retract To resolve this problem you must find a handle position that does not push the locking system up against the lock s bolt To find that place it helps to know which way the handle turns when you open the door If y...

Страница 10: ...lert after Time Delay 6 Beeps The lock is in Penalty Lockout During this period the lock will not accept any input You must wait for the penalty lockout to expire The lock will Beep Flash once when this period ends Short Warble 3 high low tones for about 2 5 seconds Short Good Combination Tone indicates the input is accepted during a Combination Change Long Warble 13 high low tones for about 10 se...

Отзывы: