background image

American Security Products Co.  

ESL20XL Operating Instructions 

Released Aug. 9, 2018 

Revision A

 

Page 3 of 10 

 

o

 

The Open Period begins timing after the completion of the Delay Period, and is indicated by a repeating 4 beeps 

and LED flashes every five seconds.  

o

 

During the Open Period, the User must key a valid combination to cause the lock to open. 

o

 

 The Open Period can be set for 1 to 9 minutes long. (F03) 

o

 

Time Delay can be canceled during the delay period by pressing “C – (any number key) - #”. 

 

 

Armored Car Time Delay Bypass

 - This feature allows the Time Delay to be used under normal access situations, 

but provides a means to bypass time delay when cash handling methods require that an Armored Car courier can take 

deposits without waiting for the delayed access.  

o

 

This feature must be Enabled (F40). 

o

 

It still requires that a valid resident User be present to open the safe.  

o

 

The Armored Car Code (User 9) can be keyed in first, followed by a valid User code or, the Armored Car Code 

can be used during the Delay Period to stop the delay, then the local User can open the lock with a valid code. 

o

 

The Armored Car Bypass can be restricted to use by only the Manager User. (F41) 
 

 

Multiple Users

 - Many cash handling protocols require that several people have access to the safe. The ESL20XL 

provides several tools to manage a Multi-User environment. These controls are uniquely tailored to support retail loss 
prevention. 

o

 

This feature must be Enabled (F10). 

o

 

The Master User, or Manager, is the only User with Administration capabilities.  

o

 

In Multi-User mode, there is no need for all Users to share the same combination, as is the case with a 

mechanical combination lock.  

o

 

This feature allows the supervisor the ability to control the subordinate Users individually and makes employee 
turnover easier to manage because individual Users can be added and deleted at will without affecting others.  

o

 

The ESL20XL allows up to eight (8) subordinate Users to be enrolled.  

o

 

A “Poor Man’s Time Lock” effect can be implemented daily where the Master User can disable the Multi-User 

Mode (F13) at the end of the day and then re-enable the mode at the beginning of the next business day. This 

causes the lock to reject all the Subordinate User Codes during off-business hours. The individual subordinate 

User codes are not lost, just disabled. 
 

 

Subordinate User Control

 - The Master User has the option of allowing, or not allowing, certain capabilities of the 

Subordinate Users as follows. 

o

 

The Subordinate User changing their own combination. (F60) 

o

 

Two Subordinate Users opening the safe in Dual Combo Mode. (F31) 

o

 

The Subordinate User authorizing Armored Car Time Delay Bypass. (F41) 
 

 

Dual Control 

- This feature provides a higher level of security, where two different combinations are required to open 

the safe.  

o

 

This feature must be Enabled (F30). 

o

 

When Dual Control is Enabled, the lock requires two Users key their individual combinations, one after the 

other, before the lock will open.  

o

 

The second User has 10 seconds to start code entry before the system discards the login and goes to sleep.  

Содержание ESL20XL

Страница 1: ...hort good combination tone 7 Re key in the new 6 digit combination again 8 Press the key If the combination input matches the first pass you should hear a long good combination tone indicating your new combination has been recorded 9 Test your new combination several times prior to closing and locking the safe Note See the ESL20XL Beep and LED Patterns table on Page 10 See Changing User Combinatio...

Страница 2: ...s from the end of the batteries making sure you don t pull on the wires and disconnect the battery clip from the PC board 5 Snap on two new 9 volt batteries onto the clips making sure they are tight with no loose contacts 6 Press the two batteries back into their pockets taking care to route the wires in the open cavity so they are not positioned where they will get pinched under the batteries whe...

Страница 3: ...e Enabled F10 o The Master User or Manager is the only User with Administration capabilities o In Multi User mode there is no need for all Users to share the same combination as is the case with a mechanical combination lock o This feature allows the supervisor the ability to control the subordinate Users individually and makes employee turnover easier to manage because individual Users can be add...

Страница 4: ...osure is the same as if someone had pushed a panic button to summon help By signaling secretly at the safe the User doesn t risk angering the robber and risking possible personal injury External Control This feature allows the ESL20XL to be disabled and enabled by an auxiliary device like an Access Manager a Key Switch external Alarm System or any other external switching method o This feature mus...

Страница 5: ...The ESL20XL s advanced features are controlled only by the Master User and are set using Function Codes A function can be turned on and off or set using the Function Code with the Master User code as authorization for changing or setting the function A Function Code is a 2 digit code that is associated to a particular setting Each Function Code has a default or standard setting which is in the loc...

Страница 6: ... 01 02 03 o To Enable Time Delay C 01 Master Code 1 o To Disable Time Delay C 01 Master Code 0 o To set the Delay Period C 02 Master Code Delay Period 1 99 minutes o To set the Open Period C 03 Master Code Open Period 1 9 minutes Multiple User Settings Functions 10 11 12 13 o To Enable Multiple User Mode C 10 Master Code 1 o To Disable Multiple User Mode C 10 Master Code 0 o To Add or Enable a Sub...

Страница 7: ...Enable Armored Car TDL Bypass C 40 Master Code 1 Note Enabling Armored Car Bypass turns on enables User 9 which is the Armored Car User The User 9 combo must be set before this feature will function See Section 4 for changing instructions o To Disable Armored Car TDL Bypass C 40 Master Code 0 o To Enable Subordinate Authorizing User Armored Car TDL Bypass C 41 Master Code 1 o To Disable Subordinat...

Страница 8: ...larm output will be caused any time the Duress code is entered by any User during opening or starting of Time Delay Requires Expansion Module o Enabling Dual Combo Mode automatically adds a User 1 even if Multi User Mode is disabled Don t forget to set a Code for User 1 or there will not be two codes to open the lock Record Keeping To track Function Settings use this table Date F Function Descript...

Страница 9: ... lock inside the door The ESL20XL relies on a solenoid to actuate this bolt That solenoid can only overcome so much resistance and if that resistance is too great the bolt does not retract To resolve this problem you must find a handle position that does not push the locking system up against the lock s bolt To find that place it helps to know which way the handle turns when you open the door If y...

Страница 10: ...lert after Time Delay 6 Beeps The lock is in Penalty Lockout During this period the lock will not accept any input You must wait for the penalty lockout to expire The lock will Beep Flash once when this period ends Short Warble 3 high low tones for about 2 5 seconds Short Good Combination Tone indicates the input is accepted during a Combination Change Long Warble 13 high low tones for about 10 se...