![ams AG AS5 63 CB Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/ams-ag/as5-63-cb-series/as5-63-cb-series_operation-manual_2936155008.webp)
Revision 1.10, 04-Mar-2010
Page 6 of 24
www.austriamicrosystems.com
4.1
Programming the AS5040/AS5045/AS5140/AS5145
Programming AS5040/AS5140 encoders requires the
AS5040-PB ZIF socket board. This adapter is compatible
with AS5040, AS5140, AS5045 and AS5145.
Jumper J6 must be close for normal operation and
programming operation.
Figure 5: AS5040-PB Programming board
By selecting the SSI tab, information of the angular position and the status bits appear:
Figure 6: SSI tab with AS5040 encoder inserted in AS5040-PB
-
Die selection: This option is for dual die AS52xx devices only. For AS50xx and AS51xx devices Die 0 (default)
must be selected.
-
Value field is the raw angle extracted from the SSI stream. The angle range is 0 (0°) to 1023 (359.6°)
-
Status field displays the status bits extracted from the SSI stream. Green light means that the airgap between
the magnet and encoder is correct. Orange light means the magnet is too close of too far.
-
CCW checkbox is the angle direction. To invert the rotating direction, check CCW.
-
Zero Position field: Set button writes the actual angle value into the Zero Position register of the encoder. This
programming is not permanent. The actual value will be 0 after zero position programming. To reset the zero
position register, or to set a new zero position, click on Reset first.
-
Read interval is the SSI stream readout and refresh rate the GUI.
AS5040-PB ZIF socket board
Device selection for autodetect:
-
Jumper position 2: AS5040
-
Jumper position 3: AS5045
-
Jumper position 4: AS5140
-
Jumper position 5: AS5145
Position of the magnet
Status bits and field alarm
Set the actual angle as
Zero Position
Counter Clockwise mode
Selected die
(dual die AS52xx devices only)
Pin 1
ams
AG
Technical
content
still
valid