AS5000 Programmer OPERATIONAL MANUAL
Revision 1.10, 04-March-2010
Page 13 of 24
www.austriamicrosystems.com
4.4
Programming the AS5134
Figure 15: AS5134-PB Programming Board
Programming AS5134 encoders requires the AS5134-PB
socket board.
Figure 16: GUI for the AS5134
-
Value field is the raw angle extracted from the interface. The angle range is 0° to 359°
-
Status field (AGC) displays the status bits depending on the set AGC values. Green light means that the
airgap between the magnet and encoder is correct. Red light means the magnet is too far away.
-
Zero Position field: Set button writes the actual angle value into the Zero Position register of the encoder. This
programming is not permanent. The actual value will be 0 after zero position programming. To reset the zero
position register, or to set a new zero position, click on Reset first.
-
Read interval is the readout and refresh rate the GUI.
-
Digital interface opens an additional window (see Figure 17), which provides all communications commands
like WRTIE_CONFIG or EN_PROG (for entering the exentended mode).
Multi Turn Counter
Additional window for the BLDC output signals
AGC value
AS5134-PB ZIF socket board
Device selection:
-
Jumper position 1: AS5134
ams
AG