![ams AG AS5 63 CB Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ams-ag/as5-63-cb-series/as5-63-cb-series_operation-manual_2936155011.webp)
Revision 1.10, 04-Mar-2010
Page 9 of 24
www.austriamicrosystems.com
4.2
Programming the AS5043
Programming AS5043 encoders requires the AS5043-PB
ZIF socket board.
Jumper J6 must be close for normal operation and
programming operation.
Figure 9: AS5043-PB Programming board
By selecting the SSI tab, information of the angular position and the status bits appear:
Figure 10: SSI tab with AS5043 inserted in AS5043-PB
-
Die selection: This option is for dual die AS52xx devices only. For AS50xx and AS51xx devices Die 0 (default)
must be selected.
-
Value field is the raw angle extracted from the SSI stream. The angle range is 0 (0°) to 1023 (359.6°)
-
Status field displays the status bits extracted from the SSI stream. Green light means that the airgap between the
magnet and encoder is correct. Orange light means the magnet is too close of too far.
-
CCW checkbox is the angle direction. To invert the rotating direction, check CCW.
-
Zero Position field: Set button writes the actual angle value into the Zero Position register of the encoder. This
programming is not permanent. The actual value will be 0 after zero position programming. To reset the zero
position register, or to set a new zero position, click on Reset first.
-
Read interval is the SSI stream readout and refresh rate the GUI.
Position of the magnet
Status bits and field alarm
Set the actual angle as
Zero Position
Counter Clockwise mode
Selected die
(dual die AS52xx devices only)
AS5043-PB ZIF socket board
Device selection for autodetect:
-
Jumper position 1: AS5043
Pin 1
ams
AG
Technical
content
still
valid