Amphenol
PCD
Shenzhen
Application Specification for
HVSL60061/HVSL630062/
HVSL280063
Doc. No.:
APCD-TD-282
Rev.: H
Page 10 of 29
Subject:
Application specification for
HVSL600061/HVSL630062/HVSL280063
ECN NO.:
C5467N
Eff. Date:: 2021-5-20
F-0866-B
3.5 Slide the end cap, cable seal, spacer, inner shielding ferrule and outer
shielding ferrule on the cable in sequence shown as below.
3.6 Strip the power cable jacket shown as below.
3.7 Slide the inner ferrule to the cut position of the jacket. Then, flip the
shielding braid backwards to cover the surface of the ferrule. Finally, wrap
2-3 layers copper foil shown as below.
Cable
spec
L1(mm)
L2(mm)
L3(mm)
25mm²
24.5±0.5
12.0±0.5
10.0ref
End cap
Spacer
Wrap copper
foil.
Inner
shielding
ferrule
Outer shielding ferrule
Flip over the shielding to
cover the ferrule.
Move the inner ferrule
until it is aligned with the
cutting surface.
Cable seal
Slide direction
Φ13.2-13.5mm ref
When the cable OD is
small, add padding to
the cable jacket.