Amphenol
PCD
Shenzhen
Application Specification for
HVSL60061/HVSL630062/
HVSL280063
Doc. No.:
APCD-TD-282
Rev.: H
Page 13 of 29
Subject:
Application specification for
HVSL600061/HVSL630062/HVSL280063
ECN NO.:
C5467N
Eff. Date:: 2021-5-20
F-0866-B
3.12 Move the outer shielding ferrule on the shell, then crimp it into shape
with a holding force > 150N.
3.13 Insert the cable into the housing shown as below.
3.14 Insert spacer, cable seal and end cap shown .
Move the outer shielding
ferrule until the ferrule
’s end
is aligned to the rear of the
shielding shell.
Crimp shielding
ferrule.
Orientate the insertion boss to the housing
position without rib.
Insert insertion to the housing
The two sides
’ latches
are completely visible.
15.6±0.1mm ref