Remote Monitoring / Data Transmission via LAN

PAGE 9

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

CASCADE

INPUT

OUTPUT

AMP. BYPASS

ADD

+OUT

GND

-OUT

+IN

GND

-IN

+OUT

GND

-OUT

AMP7

+IN

GND

-IN

+OUT

GND

-OUT

AMP8

+OUT

GND

-OUT

STDBY

A B

1

8

16

8

4

2

1

32 64 128

FAULT

NO
CONTACT

RS 485

LINK

OPEN

LINK

OPEN

AMPERES ELECTRONICS

amperes

R

Model : AX3800

MADE IN MALAYSIA

AMP.CHANGEOVER

DC input 24V

Max. 500mA

MKII

amperes electronics

another quality product from

iPX 5500

ETHERNE

T COMM BO

X

EHTERN

ET AD

DRESS

ETHERNE

T

RESE

T

ampere

s

CON

TACT

N / O

TRIG

GER

A

RS48

5  B

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

CASCADE

INPUT

OUTPUT

AMP. BYPASS

ADD

+OUT

GND

-OUT

+IN

GND

-IN

+OUT

GND

-OUT

AMP7

+IN

GND

-IN

+OUT

GND

-OUT

AMP8

+OUT

GND

-OUT

STDBY

A B

1

8

16

8

4

2

1

32 64 128

FAULT

NO
CONTACT

RS 485

LINK

OPEN

LINK

OPEN

AMPERES ELECTRONICS

amperes

R

Model : AX3800

MADE IN MALAYSIA

AMP.CHANGEOVER

DC input 24V

Max. 500mA

MKII

amperes electronics

another quality product from

PC with monitoring 

software / PMX LAN

Amperes iPX5500

Comm.Box

AX3800 Unit # 1

AX3800 Unit # 2

RS485

Loop to 

next 

AX3800

Address Setting

Address Setting

Ethernet / LAN

AX3800 can be remotely monitored by external software to check condition of the amplifiers as well as notification when-

ever a duty amplifier failed.

RS485 data is provided which can be directly connected to local PC via RS485-232 converter or through network via 

Amperes iPX5500 Communication Box.

Application with iPX5500 can be from single or multiple locations. When there are several AX3800 connected, it is 

important to set the address correctly with each AX3800 assigned to a unique number.

API can be obtained for 3rd party software integration.

Fault Detection 

AX3800 may work a little different from other auto standby amplifier fault changeover. It sends Pilot Tones of 20 kHz to 

amplifiers at intervals and shift from one channel to another to reduce loading strain. A slight delay in detection shall 

occur but is more beneficial in the long run, prolonging the life span of amplifiers.

Whenever Pilot Tone is sent out, a PT Active LED at front panel shall lit.

Pilot Tones

AX3800 detects availability of returning Pilot Tones at every channel. Missing Pilot Tone shall be interpreted as faulty 

amplifier at that particular channel.

A minimum level of 50V signal must be presence to avoid unnecessary fault diagnosis. Thereby, it is recommended that 

all amplifiers’ output levels be set to minimum 50%.

Fault Detection

Any faulty channel shall be indicated by top row of LEDs ( AMP.NORMAL / FAULT ) to red. A fault shall be accompanied 

by AMP FAULT ALERT LED and also switchable buzzer switch. Concurrently, a data string shall be transmitted ( RS485 

) along with activation of a dry contact.

As only one channel is allowed for changeover, which is to prevent overloading, only one LED shall lit at the second row 

of LEDs. ( AMP. CHANGEOVER ).

Fault Changeover and Indication

AX3800 Auto Amplifier Fault Changeover

Содержание AX3800

Страница 1: ...without human intervention to comply with various Codes of Practices such as BS EN or SS By means of pilot tone injection at intervals it ensures power amplifiers are not loaded all the time to preven...

Страница 2: ...tus of connected amplifier with AMP NORMAL FAULT LEDs Green normal operating Red amplifier faulty Off monitoring bypassed AMP CHANGEOVER LEDs Green faulty and standby amplifier overtake the position o...

Страница 3: ...r item 10 Channel 1 shall have higher priority for standby takeover than subsequent channels This is to ensure that ampli fier serving highest priority shall be connected to channel with lower number...

Страница 4: ...2 1 3 5 4 6 ALL CALL PAGING ZONE SELECTION OVERRIDE OVERRIDE AX 3800 amperes AMP NORMAL FAULT AMP CHANGEOVER ON OFF AMP FAULT ALERT PILOT TONE AMP1 AMP2 AMP3 AMP4 AMP5 AMP6 AMP7 AMP8 AMPSTDBY STANDBY...

Страница 5: ...dB POWER PROTECT CLIP 480 Watts amperes PA 2480 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 ampe res ampe res O I POWER PUBLIC ADDRESS POWER AMPLIFIER SIGNAL 40 dB SIGNAL...

Страница 6: ...ntroller to the inputs of power amplifiers Audio source 1 shall feed to amplifier 1 Link switch 1 shall be switched to OPEN position Audio source 2 shall feed to amplifier 2 5 Link switch 2 3 and 4 sh...

Страница 7: ...K OPEN BALANCE AUDIO SIGNAL From Amp Output 1 To Zone Selector From standby amplifier output Channel bypass DIP Switches When connecting amplifier outputs to 100V section at the terminals ensure the p...

Страница 8: ...amplifier to serve more than 8 duty units AX3800 will need to be stacked up or cascaded The link between them has been made simpler using RJ45 connectors Unit 1 Unit 2 Unit 3 Cat5e Cat5e To standby a...

Страница 9: ...etwork via Amperes iPX5500 Communication Box Application with iPX5500 can be from single or multiple locations When there are several AX3800 connected it is important to set the address correctly with...

Страница 10: ...red channel To protect standby amplifier only 1 failed duty amplifier is allowed for changeover at any one time Switch OFF the power amplifier at Ch 8 When PT lits AMP 8 LED will turn red and Changeov...

Страница 11: ...asier Channel isolation switch for unused or un monitored channel Individual channel status indicators normal fault and changeover status Technical Specifications Operating voltage Power consumption I...

Страница 12: ...med by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the produc...