Summary of Features
PAGE 11
Cater for 8 duty and 1 standby
Expandable for 1 standby to cater for more than 8 duty amps.
Built in Pilot Tone generator, transmit in intervals and senses at sequence to protect
amplifiers
Overloading protection by allowing only a single take over
Prioritised changeover where the lower numbered amplifier shall be preferred for
take over if more than two units are down
Short fault detection time within 20 seconds
Changeover at input and output section simultaneously ; suitable for matrix system
installations
Input link switch ; making connection of channels sharing the same source easier
Channel isolation switch for unused or un-monitored channel
Individual channel status indicators ; normal, fault and changeover status
Technical Specifications
Operating voltage
Power consumption
Input impedance
Audio output gain
Pilot tone interval
Pilot tone frequency
Detection line
Detection level
Failure detection time
Failure recovery time
Zone load rating
Status indication LED
Changeover alert
Changeover section
Dimensions ( W x H X D )
24V DC ; 1A
6.8 W ( 0.3 A )
8 Ch balanced line signal
10 k Ohm
Unity
8 seconds / channel
20 KHz ( +/- 5% ) kHz
70 / 100 V line
50 V rms min
20 seconds ( max )
20 seconds ( max )
500W 100V line max ( 1000W on request )
Normal ; Fault ; Changeover
Buzzer with switch
Input and output simultaneously
482 x 88 x 180 mm
3.15 kg
Standby consumption
2.4 W ( 0.1 A )
Weight
AX3800 Auto Amplifier Fault Changeover