background image

Warranty Conditions

Disclaimer

AMPERES ELECTRONICS SDN BHD

MADE IN MALAYSIA

Published : JAN 2022

ISO 9001: 2015

Design & Manufacture of Public Address Equipment and Systems

Certificate No. 16895 / A / 0001 / UK / En

Information contained in this manual is subject to change without prior notice and does not represent a 

commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD  shall not be liable for any 

loss or damages whatsoever arising from the use of information or any error contained in this manual.

It is recommended that all services and repairs on this product be carried out by AMPERES 

ELECTRONICS SDN BHD or its authorized service agents.

AMPERES series must only be used for the purpose they were intended by the manufacturer and in 

conjunction with this operating manual.

AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages 

caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by 

the manufacturer.

Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes 

Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics 

Sdn Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, 

Malaysia or its authorized dealers. This warranty is not valid if repairs are performed by unauthorized 

personnel or service centres.

This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as 

well as removal and installation of the product from the main system are for the account of the purchaser. 

This warranty shall not extend to the replacement of the unit.

This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using 

the product with power supply voltage other than what is shown on the product, or any other power supply 

source / adaptor not recommended by the manufacturer.

This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every other cause 

not directly related to the unit.

This warranty does not include any indemnity in favor of the purchaser or the dealer for the period of usage 

of the unit. The warranty also does not cover any damages which may inflict to people and things when 

using the product.

This warranty certificate is valid only for the described product, and is not valid if modifications are made on 

this certificate or on the identification label applied on the product.

This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from 

the date of purchase or for a specified period in countries where it is stated by a national law. In this case, 

the extension is valid only in the country where the product is purchased.

Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if 

the design changes or improvements are made.

Содержание AX3800

Страница 1: ...without human intervention to comply with various Codes of Practices such as BS EN or SS By means of pilot tone injection at intervals it ensures power amplifiers are not loaded all the time to preven...

Страница 2: ...tus of connected amplifier with AMP NORMAL FAULT LEDs Green normal operating Red amplifier faulty Off monitoring bypassed AMP CHANGEOVER LEDs Green faulty and standby amplifier overtake the position o...

Страница 3: ...r item 10 Channel 1 shall have higher priority for standby takeover than subsequent channels This is to ensure that ampli fier serving highest priority shall be connected to channel with lower number...

Страница 4: ...2 1 3 5 4 6 ALL CALL PAGING ZONE SELECTION OVERRIDE OVERRIDE AX 3800 amperes AMP NORMAL FAULT AMP CHANGEOVER ON OFF AMP FAULT ALERT PILOT TONE AMP1 AMP2 AMP3 AMP4 AMP5 AMP6 AMP7 AMP8 AMPSTDBY STANDBY...

Страница 5: ...dB POWER PROTECT CLIP 480 Watts amperes PA 2480 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 ampe res ampe res O I POWER PUBLIC ADDRESS POWER AMPLIFIER SIGNAL 40 dB SIGNAL...

Страница 6: ...ntroller to the inputs of power amplifiers Audio source 1 shall feed to amplifier 1 Link switch 1 shall be switched to OPEN position Audio source 2 shall feed to amplifier 2 5 Link switch 2 3 and 4 sh...

Страница 7: ...K OPEN BALANCE AUDIO SIGNAL From Amp Output 1 To Zone Selector From standby amplifier output Channel bypass DIP Switches When connecting amplifier outputs to 100V section at the terminals ensure the p...

Страница 8: ...amplifier to serve more than 8 duty units AX3800 will need to be stacked up or cascaded The link between them has been made simpler using RJ45 connectors Unit 1 Unit 2 Unit 3 Cat5e Cat5e To standby a...

Страница 9: ...etwork via Amperes iPX5500 Communication Box Application with iPX5500 can be from single or multiple locations When there are several AX3800 connected it is important to set the address correctly with...

Страница 10: ...red channel To protect standby amplifier only 1 failed duty amplifier is allowed for changeover at any one time Switch OFF the power amplifier at Ch 8 When PT lits AMP 8 LED will turn red and Changeov...

Страница 11: ...asier Channel isolation switch for unused or un monitored channel Individual channel status indicators normal fault and changeover status Technical Specifications Operating voltage Power consumption I...

Страница 12: ...med by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the produc...

Отзывы: