Testing the Installation

Follow the simple guidelines below to test the function of standby amplifier changeover when the duty amplifier failed.

Power up :

Connect 24V DC from centralised power supply unit, ie. Amperes PS9400. If the unit is to operate using power adap-

tor, use 24V DC type with 1 A rating. Usage of unregulated power supply may damage the equipment.

When AX3800 is powered up, it will take approximately 10 seconds to test all connected amplifiers. Green LED 

indicates that the amplifier is normal and red is the amplifier is faulty.

Test Detection Fault at Individual Channel

Switch OFF the power of amplifier at 

Ch. 1

When Pilot Tone LED lits, AMP 1 LED will turn red. AMP.CHANGEOVER 

LED will lit to indicate the amplifier connected is faulty.

Press the buzzer button ON and OFF to ensure switch and the buzzer is 

working.

Switch ON the power amplifier at Ch.1

When the Pilot Tone LED lits again, AMP 1 LED will turn green. Buzzer 

will turn off.

Repeat the above steps for Ch.2 to 8

Test Priority Function

Channel 1 shall have the highest priority over others, so as Ch.2 over 3 and so forth. Thereby, always install amplifier 

with highest priority at lower numbered channel. To protect standby amplifier, only 1 failed duty amplifier is allowed for 

changeover at any one time.

Switch OFF the power amplifier at Ch. 8

When PT lits, AMP.8 LED will turn red and Changeover LED turn green, 

accompanied by buzzer. 

Switch OFF the power amplifier at Ch. 7 

while amplifier at Ch.8 still OFF

AMP.7 and AMP.8 LED will both turn red and Amp.Changeover LED at 

Ch.7 will lit and Ch.8 off. Standby replacement is now at Ch.7 since it has 

higher priority.

Switch OFF the power amplifier at Ch. 6 

while amplifier at Ch.7 and 8 still OFF

AMP6, AMP.7 and AMP.8 LEDs will turn red. Amp.Changeover LED at 

Ch.6 will lit and Ch.7 and 8 off. Now, standby unit is replacing the duty 

amplifier position of Ch. 7 and 8.

Repeat the above process for other amplifiers and should observe the same pattern, each time with lower numbered 

channel connected to standby unit, replacing higher numbered ones. 

Amplifier Recovery Function

Will all amplifiers at faulty state, here we shall recover these amplifiers one at a time and observe the LED response.

Switch On power amplifier at Ch.1, when Pilot Tone lits, AMP.1 LED shall turn green and AMP.CHANGEOVER LED 2 

shall lit, to indicate that the standby changeover is now at Ch. 2.

Repeat the above steps for subsequent channels until all AMP.1 to AMP.8 LEDs are green and AMP.CHANGEOVER 

LEDs are Off.

AX3800 Auto Amplifier Fault Changeover

Содержание AX3800

Страница 1: ...without human intervention to comply with various Codes of Practices such as BS EN or SS By means of pilot tone injection at intervals it ensures power amplifiers are not loaded all the time to preven...

Страница 2: ...tus of connected amplifier with AMP NORMAL FAULT LEDs Green normal operating Red amplifier faulty Off monitoring bypassed AMP CHANGEOVER LEDs Green faulty and standby amplifier overtake the position o...

Страница 3: ...r item 10 Channel 1 shall have higher priority for standby takeover than subsequent channels This is to ensure that ampli fier serving highest priority shall be connected to channel with lower number...

Страница 4: ...2 1 3 5 4 6 ALL CALL PAGING ZONE SELECTION OVERRIDE OVERRIDE AX 3800 amperes AMP NORMAL FAULT AMP CHANGEOVER ON OFF AMP FAULT ALERT PILOT TONE AMP1 AMP2 AMP3 AMP4 AMP5 AMP6 AMP7 AMP8 AMPSTDBY STANDBY...

Страница 5: ...dB POWER PROTECT CLIP 480 Watts amperes PA 2480 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 SPEAKER VOLUME OVERIDE OFF 1 2 3 4 5 ampe res ampe res O I POWER PUBLIC ADDRESS POWER AMPLIFIER SIGNAL 40 dB SIGNAL...

Страница 6: ...ntroller to the inputs of power amplifiers Audio source 1 shall feed to amplifier 1 Link switch 1 shall be switched to OPEN position Audio source 2 shall feed to amplifier 2 5 Link switch 2 3 and 4 sh...

Страница 7: ...K OPEN BALANCE AUDIO SIGNAL From Amp Output 1 To Zone Selector From standby amplifier output Channel bypass DIP Switches When connecting amplifier outputs to 100V section at the terminals ensure the p...

Страница 8: ...amplifier to serve more than 8 duty units AX3800 will need to be stacked up or cascaded The link between them has been made simpler using RJ45 connectors Unit 1 Unit 2 Unit 3 Cat5e Cat5e To standby a...

Страница 9: ...etwork via Amperes iPX5500 Communication Box Application with iPX5500 can be from single or multiple locations When there are several AX3800 connected it is important to set the address correctly with...

Страница 10: ...red channel To protect standby amplifier only 1 failed duty amplifier is allowed for changeover at any one time Switch OFF the power amplifier at Ch 8 When PT lits AMP 8 LED will turn red and Changeov...

Страница 11: ...asier Channel isolation switch for unused or un monitored channel Individual channel status indicators normal fault and changeover status Technical Specifications Operating voltage Power consumption I...

Страница 12: ...med by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the produc...

Отзывы: