UART_Rx
BOOL
Set by controller when its serial port is receiving data
UART_Tx
BOOL
Set by controller when its serial port is transmitting data
EOL_SC
BOOL
Set by co
ntroller when the L1 fieldbus is short circuited (R<1000Ω), clear
otherwise
4.1.2 iMac_SystemControl_DT
This UDT stores the iMAC2 Controller Runtime System Control bits. It is used by iMac_Ctrl_Runtime_DT. It
has the following members.
Member Name
Data
Type
Description
StartUp
BOOL
Set by controller on first SLP loop following power up
Always1
BOOL
This bit is always set to 1
SeqDownFromL2
BOOL
Sequence Down Bit from Upstream iMAC Controller
SeqUpFromL1
BOOL
Sequence Up Bit from Downstream iMAC Controller/SQM module
SwInput1
BOOL
iMAC Controller SW1 status: 1 = closed, 0 = open.
SwInput2
BOOL
iMAC Controller SW2 status: 1 = closed, 0 = open.
SwInput3
BOOL
iMAC Controller SW3 status: 1 = closed, 0 = open.
AsrtCtrlRelay
BOOL
Set by application (SLP) software to attempt to energise the CR relay. CR will
energise if and only if EOL Module comms is also healthy. Clear to de-
energise CR relay.
AsrtAuxRelay
BOOL
Set by application (SLP) software to energise AR relay. Clear to de-energise
AR relay.
SeqUpOnL2
BOOL
Upstream sequence control bit
SeqDownOnL1
BOOL
Downstream sequence control bit
EnFlashWrite
BOOL
Enables data to be written to the iMAC Controller’s flash memory using
Modbus write commands
FullSysMenu
BOOL
The following menu functions are disabled when FullSysMenu = 0 & enabled
when FullSysMenu = 1 -
System Menu ‘CLR DPT’ item, Maintenance page
F1 - Clear individual OnScan Bit
MinSysMenu
BOOL
The following menu functions are disabled when MinSysMenu = 0 & enabled
when MinSysMenu = 1 - System Menu (SHIFT+MENU), Debug Menu,