13.   ERROR CODES

If you use a wired type remote control, error codes will appear on the remote 
control display. If you use a wireless remote control, the lamp on the IR 
receiver unit will output error codes by way of blinking patterns. See the 
lamp blinking patterns and error codes in the table below. 

An error display is displayed only during operation.

Error display

Wired 

remote 

controller 

Error code

Mode

DESCRIPTION

OPERA-

TION  
lamp 

(green)

TIMER  

lamp 

(orange)

ECONO-

MY lamp 

(green)

 

(1)

 

(1)

Communi-
cation

Serial commu-
nication error

 

(1)

 

(2)

Communi-
cation

Remote controller 
communication 
error

 

(1)

 

(5)

Communi-
cation

Scan error

 

(2)

 

(1)

Function 
setting

Initial setting 
error

 

(2)

 

(2)

Function 
setting

Indoor unit 
capacity error

 

(2)

 

(3)

Function 
setting

Connection 
disabled 
(series error)

 

(2)

 

(4)

Function 
setting

Connection 
unit number 
error

 

(3)

 

(2)

Indoor  
unit

Indoor unit 
main PCB 
error

 

(3)

 

(5)

Indoor  
unit

Manual auto 
switch error

 

(4)

 

(1)

Indoor  
unit

Room 
(temperature) 
thermistor error

 

(4)

 

(2)

Indoor  
unit

Indoor unit 

Heat Ex. 

sensor error

 

(5)

 

(1)

Indoor  
unit

Indoor unit fan 
motor error

 

(5)

 

(3)

Indoor  
unit

Water Drain 
error

 

(5)

 

(15)

Indoor  
unit

Indoor unit 
error

 

(6)

 

(2)

Outdoor 
unit

Outdoor unit 
main PCB 
error

 

(6)

 

(3)

Outdoor 
unit

Inverter PCB 
error

 

(6)

 

(4)

Outdoor 
unit

Active filter 

error, PFC 
circuit error

 

(6)

 

(5)

Outdoor 
unit

IPM error

 

(6)

 

(10)

Outdoor 
unit

Display panel 
error

 

(7)

 

(1)

Outdoor 
unit

Discharge 
thermistor 
error

 

(7)

 

(2)

Outdoor 
unit

Compressor 
thermistor 
error

 

(7)

 

(3)

Outdoor 
unit

Outdoor unit 

Heat Ex. 

Sensor error

 

(7)

 

(4)

Outdoor 
unit

Outdoor 
thermistor 
error

 

(7)

 

(5)

Outdoor 
unit

Suction Gas 
thermistor 
error

 

(7)

 

(7)

Outdoor 
unit

Heat sink 
thermistor 
error

 

(8)

 

(2)

Outdoor 
unit

Sub-cool Heat 

Ex. gas 

thermistor 
error 

 

(8)

 

(3)

Outdoor 
unit

Liquid pipe 
thermistor 
error

 

(8)

 

(4)

Outdoor 
unit

Current sensor 
error

 

(8)

 

(6)

Outdoor 
unit

Pressure 
sensor error

 

(9)

 

(4)

Outdoor 
unit

Trip detection

 

(9)

 

(5)

Outdoor 
unit

Compressor 
motor control 
error

 

(9)

 

(7)

Outdoor 
unit

Outdoor unit 
fan motor 1 
error

 

(9)

 

(9)

Outdoor 
unit

4-way valve 
error

 

(10)

 

(1)

Refrigerant 
system

Discharge 
temperature 1 
error

 

(10)

 

(3)

Refrigerant 
system

Compressor 
temperature 
error

 

(10)

 

(5)

Refrigerant 
system

Pressure  
error 2

 

(13)

 

(2)

Branch  

box

Unit flow 

divider error

9378626041-03_IM.indb   7

14/5/2555   9:07:16

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание UTY-LRHYM

Страница 1: ...kά Português Русский Tϋrkçe PART NO 9378626041 03 INSTALLATION MANUAL For authorized service personnel only AIR CONDITIONER IR RECEIVER UNIT UTY LRHYM 9378626041 03_IM indb 1 14 5 2555 9 07 09 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Страница 2: ...fore touching electrical components For the air conditioner to operate satisfactorily install it as outlined in this installation manual Installation work must be performed in accordance with national wiring standards by authorized personnel only Do not cut shorten or extend the cable in the standard parts Do not turn on the power until all installation work is complete CAUTION This mark indicates...

Страница 3: ...al reception angle Indoor unit Ceiling 120 Remote controller Max 10m 5m Receiver unit Signal reception angle 6 INSTALLING THE RECEIVER UNIT CAUTION Do not touch the PCB or PCB parts of receiver unit directly with your hands Fixing of the holder cover with the screws in the standard parts may be unsuitable if the wall or ceiling material is weak If so prepare screws suitable for the wall or ceiling...

Страница 4: ...NECT Tape 6 1 Select the wiring pattern Pattern A From the top of the receiver unit No additional work is necessary Pattern B From behind the receiver unit Perform the following procedure to route the wiring behind the receiver unit 1 2 Holder PCB Holder cover Screw 1 1 Remove the screw 2 Remove holder PCB from holder cover 1 Route the wiring as shown in the figure 2 1 Hook Holder cover Screw 1 Re...

Страница 5: ...each indoor unit for details EXAMPLE Connect the wires and then use heat shrink tubing to protect the connection from dust and water droplets Provide a trap in the receiver unit wiring To prevent water droplets from entering the receiver unit and the connector If the wiring length is 10m replace with receiver unit wire C optional parts Receiver unit wire A 5m CONNECT Receiver unit Heat shrink tubi...

Страница 6: ...ng description Function number Setting value No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature sensor If setting value is 01 Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor The air conditioner signal code is set to A prior to shipment Contact your retailer to change the signal code The remot...

Страница 7: ...act your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Use the following steps to select the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the remote controller disp...

Страница 8: ... unit Indoor unit fan motor error 5 3 Indoor unit Water Drain error 5 15 Indoor unit Indoor unit error 6 2 Outdoor unit Outdoor unit main PCB error 6 3 Outdoor unit Inverter PCB error 6 4 Outdoor unit Active filter error PFC circuit error 6 5 Outdoor unit IPM error 6 10 Outdoor unit Display panel error 7 1 Outdoor unit Discharge thermistor error 7 2 Outdoor unit Compressor thermistor error 7 3 Out...

Страница 9: ...Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Wired Remote Controller Display Error code 9378626041 03_IM indb 8 14 5 2555 9 07 16 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Отзывы: