background image

En-1

2.  ACCESSORIES

The following installation parts are supplied.
Use them as required.

Name and Shape

Q’ty

Application

Installation manual

1

This manual

Operating manual

1

Instruction book for operation

Receiver unit

1

For receiving the signal from the 
remote controller

Cover

1

For covering receiver unit

Insulation

1

For protecting PCB from dust

Receiver unit wire A
5m

1

For connecting receiver unit wire B 
to receiver unit

Receiver unit wire B
0.2m

1

For connecting receiver unit wire A 
to PCB of indoor unit

Bracket (cover)

1

For fixing receiver unit to the wall or 

ceiling

Screw (M3 x 12mm)

2

For installing remote controller 
holder to the wall

Screw (M4 x 20mm)

2

For installing receiver unit to the 
wall or ceiling

Remote  
controller

1

For air conditioner operation

Battery (R03/LR03)

2

For remote controller

Remote
controller  
holder

1

Use as remote controller holder

1.  SAFETY PRECAUTIONS

Let the customer keep this installation manual because it is needed 

 

when the air conditioner or receiver unit is serviced or moved.

 

WARNING

This mark indicates procedures which, if improperly 
performed, might lead to the death or serious injury of 
the user.

Never touch electrical components immediately after the power supply 

 

has been turned off. Electrical shock may occur. After turning off 
the power, always wait 5 minutes or more before touching electrical 
components.

For the air conditioner to operate satisfactorily, install it as outlined in 

 

this installation manual.

Installation work must be performed in accordance with national wiring 

 

standards by authorized personnel only.

Do not cut, shorten, or extend the cable in the standard parts.

 

Do not turn on the power until all installation work is complete.

 

 

CAUTION

This mark indicates procedures which, if improperly 
performed, might possibly result in personal harm to 
the user, or damage to property.

Do not wire the receiver unit wire together with or parallel to the 

 

connection cables, transmission cables, remote controller cables, bus 
cable and power supply cables of the indoor and outdoor units. It may 
cause erroneous operation.

Do not install the receiver unit cable near a source of electromagnetic 

 

waves.

Do not install where there is the danger of combustible gas leakage.

 

Do not install near heat sources, steam.

 

Contents

1.  SAFETY PRECAUTIONS .....................................................................1

2.  ACCESSORIES ....................................................................................1

3.  OPTIONAL PARTS................................................................................2

4.  FUNCTIONS AND DIMENSIONS .........................................................2

5.  SELECTING THE INSTALLATION LOCATION.....................................2

6.  INSTALLING THE RECEIVER UNIT

6.1. Select the wiring pattern .................................................................3

6.2. Select the installation method ........................................................3

7.  WIRING .................................................................................................3

8.  TURNING ON THE POWER .................................................................4

9.  SETTING THE REMOTE CONTROLLER

9.1. Load batteries (R03/LR03 × 2) .......................................................4

9.2. Installing the remote controller holder ............................................4

10. FUNCTION SETTING ...........................................................................4

11.  SELECTING THE REMOTE CONTROLLER SIGNAL CODE ..............6

12. TEST OPERATION ...............................................................................6

13. ERROR CODES ...................................................................................7

9378626041-03_IM.indb   1

14/5/2555   9:07:10

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание UTY-LRHYM

Страница 1: ...kά Português Русский Tϋrkçe PART NO 9378626041 03 INSTALLATION MANUAL For authorized service personnel only AIR CONDITIONER IR RECEIVER UNIT UTY LRHYM 9378626041 03_IM indb 1 14 5 2555 9 07 09 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Страница 2: ...fore touching electrical components For the air conditioner to operate satisfactorily install it as outlined in this installation manual Installation work must be performed in accordance with national wiring standards by authorized personnel only Do not cut shorten or extend the cable in the standard parts Do not turn on the power until all installation work is complete CAUTION This mark indicates...

Страница 3: ...al reception angle Indoor unit Ceiling 120 Remote controller Max 10m 5m Receiver unit Signal reception angle 6 INSTALLING THE RECEIVER UNIT CAUTION Do not touch the PCB or PCB parts of receiver unit directly with your hands Fixing of the holder cover with the screws in the standard parts may be unsuitable if the wall or ceiling material is weak If so prepare screws suitable for the wall or ceiling...

Страница 4: ...NECT Tape 6 1 Select the wiring pattern Pattern A From the top of the receiver unit No additional work is necessary Pattern B From behind the receiver unit Perform the following procedure to route the wiring behind the receiver unit 1 2 Holder PCB Holder cover Screw 1 1 Remove the screw 2 Remove holder PCB from holder cover 1 Route the wiring as shown in the figure 2 1 Hook Holder cover Screw 1 Re...

Страница 5: ...each indoor unit for details EXAMPLE Connect the wires and then use heat shrink tubing to protect the connection from dust and water droplets Provide a trap in the receiver unit wiring To prevent water droplets from entering the receiver unit and the connector If the wiring length is 10m replace with receiver unit wire C optional parts Receiver unit wire A 5m CONNECT Receiver unit Heat shrink tubi...

Страница 6: ...ng description Function number Setting value No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature sensor If setting value is 01 Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor The air conditioner signal code is set to A prior to shipment Contact your retailer to change the signal code The remot...

Страница 7: ...act your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Use the following steps to select the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the remote controller disp...

Страница 8: ... unit Indoor unit fan motor error 5 3 Indoor unit Water Drain error 5 15 Indoor unit Indoor unit error 6 2 Outdoor unit Outdoor unit main PCB error 6 3 Outdoor unit Inverter PCB error 6 4 Outdoor unit Active filter error PFC circuit error 6 5 Outdoor unit IPM error 6 10 Outdoor unit Display panel error 7 1 Outdoor unit Discharge thermistor error 7 2 Outdoor unit Compressor thermistor error 7 3 Out...

Страница 9: ...Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Wired Remote Controller Display Error code 9378626041 03_IM indb 8 14 5 2555 9 07 16 AMP Air Conditioning www ampair co uk sales ampair co uk ...