background image

En-3

II. Attaching the receiver unit (Wiring pattern A)

1

2

Holder 
(PCB)

Holder cover

Screw

1

  Remove the screw.

2

  Remove holder (PCB) from  

 

holder cover.

1

  Cut the projections in the areas  

 

indicated with a 

 and  

 

remove them.

 

(Be careful not to injure  

 

yourself on the cut edges of  

 

the holder cover.)

1

2

2

Screws (M4 x 20mm)

Wall or 
ceiling

Hook

1

2

1

  Affix the insulation to the 

 

holder cover.

2

  Attach the holder cover to the  

 

wall or ceiling with the screws  

 

(included with the standard  

 

parts).

1

  Reattach holder cover. (Make  

 

sure that the hook on the  

 

holder cover is caught on the  

 

holder [PCB].)

2

  Fix holder (PCB) by the screw.

7.  WIRING

 

WARNING

Before starting work, make sure that power is not being supplied to the 

 

indoor unit.

Always fasten the outside covering of the connection cord with the cord 

 

clamp. (If the insulator is chafed, electric leakage may occur.)

 

CAUTION

Do not touch the PCB or PCB parts of indoor unit directly with your 

 

hands.

When fixing the wiring, be careful to avoid touching the edge of the 

 

indoor unit or the control box.

Install the remote controller wires so as not to be direct touched with 

 

your hand.

Make sure to use and roll an insulation tube of more than 1 mm thick 

 

at the connection point of the receiver unit wire A and the receiver unit 
wire B.

Insulation tube

CONNECT

Tape

6.1. Select the wiring pattern

Pattern A  From the top of the receiver unit: No additional work is  

 

   

necessary.

Pattern B  From behind the receiver unit: Perform the following procedure  
   

to route the wiring behind the receiver unit.

1

2

Holder 
(PCB)

Holder cover

Screw

1

1

  Remove the screw.

2

  Remove holder (PCB) from  

 

holder cover.

1

  Route the wiring as shown  

 

in the figure.

2

1

Hook

Holder cover

Screw

1

  Reattach holder cover. (Make sure that the hook on the holder  

 

cover is caught on the holder [PCB].)

2

  Fix holder (PCB) by the screw.

6.2. Select the installation method

Method 1  Receiver unit embedded in a wall or ceiling:  
 

 

Refer to “I. Embedding the receiver unit.”

Method 2  Receiver unit attached to a wall or ceiling:  
 

 

Refer to “II. Attaching the receiver unit.”

I. Embedding the receiver unit (Wiring pattern A or B)

60mm - 64mm

120mm - 140mm

Screws (M4 x 20mm)

1

2

2

Wall or ceiling

1

  Make a hole in the wall or  

 

ceiling.

 

(Depth: 25mm or more)

1

  Affix the insulation to the 

 

 

holder cover.

2

  Attach the holder cover and  

 

bracket (cover) to the wall 

 

or ceiling with the screws  

 

(included with the standard  

 

parts).

Cover

Bracket 
(cover)

Cover

1

1

2

1

  Install the cover.

 

Hook the 2 projections on the top of the cover onto the bracket  

 

(cover), and then hook the projection on the bottom of the cover  

 

onto the bracket (cover).

2

  Make sure that there is no gap between the cover and the wall  

 

or ceiling.

3

4

3

3

1

1

2

1

2

2

9378626041-03_IM.indb   3

14/5/2555   9:07:11

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание UTY-LRHYM

Страница 1: ...kά Português Русский Tϋrkçe PART NO 9378626041 03 INSTALLATION MANUAL For authorized service personnel only AIR CONDITIONER IR RECEIVER UNIT UTY LRHYM 9378626041 03_IM indb 1 14 5 2555 9 07 09 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Страница 2: ...fore touching electrical components For the air conditioner to operate satisfactorily install it as outlined in this installation manual Installation work must be performed in accordance with national wiring standards by authorized personnel only Do not cut shorten or extend the cable in the standard parts Do not turn on the power until all installation work is complete CAUTION This mark indicates...

Страница 3: ...al reception angle Indoor unit Ceiling 120 Remote controller Max 10m 5m Receiver unit Signal reception angle 6 INSTALLING THE RECEIVER UNIT CAUTION Do not touch the PCB or PCB parts of receiver unit directly with your hands Fixing of the holder cover with the screws in the standard parts may be unsuitable if the wall or ceiling material is weak If so prepare screws suitable for the wall or ceiling...

Страница 4: ...NECT Tape 6 1 Select the wiring pattern Pattern A From the top of the receiver unit No additional work is necessary Pattern B From behind the receiver unit Perform the following procedure to route the wiring behind the receiver unit 1 2 Holder PCB Holder cover Screw 1 1 Remove the screw 2 Remove holder PCB from holder cover 1 Route the wiring as shown in the figure 2 1 Hook Holder cover Screw 1 Re...

Страница 5: ...each indoor unit for details EXAMPLE Connect the wires and then use heat shrink tubing to protect the connection from dust and water droplets Provide a trap in the receiver unit wiring To prevent water droplets from entering the receiver unit and the connector If the wiring length is 10m replace with receiver unit wire C optional parts Receiver unit wire A 5m CONNECT Receiver unit Heat shrink tubi...

Страница 6: ...ng description Function number Setting value No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature sensor If setting value is 01 Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor The air conditioner signal code is set to A prior to shipment Contact your retailer to change the signal code The remot...

Страница 7: ...act your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Use the following steps to select the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the remote controller disp...

Страница 8: ... unit Indoor unit fan motor error 5 3 Indoor unit Water Drain error 5 15 Indoor unit Indoor unit error 6 2 Outdoor unit Outdoor unit main PCB error 6 3 Outdoor unit Inverter PCB error 6 4 Outdoor unit Active filter error PFC circuit error 6 5 Outdoor unit IPM error 6 10 Outdoor unit Display panel error 7 1 Outdoor unit Discharge thermistor error 7 2 Outdoor unit Compressor thermistor error 7 3 Out...

Страница 9: ...Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Wired Remote Controller Display Error code 9378626041 03_IM indb 8 14 5 2555 9 07 16 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Отзывы: