background image

En-5

1) Filter sign

The indoor unit has a sign to inform the user that it is time to clean the filter. 

Select the time setting for the filter sign display interval in the table below 

according to the amount of dust or debris in the room. If you do not wish the 

filter sign to be displayed, select the setting value for “No indication”.

( ...  Factory setting)

Setting description

Function number

Setting value

Standard

11

00

Long interval

01

Short interval

02

No indication

03

The filter sign interval time is different according to Indoor unit type.

Please refer to the installation manual of each indoor unit for details.

 

FILTER INDICATOR RESET

It lights on if the filter became dirty.

Clean the filter referring to “CLEANING AND CARE (indoor unit operating 

manual)”.
After cleaning, press the MANUAL AUTO button (indoor unit) for 2 seconds 
or less on the indoor unit.

  

Indicator Lamp

OPERATION or

TIMER or

ECONOMY or

: Flashing (3 times)

: OFF

2) Static pressure

Select appropriate static pressure according to the installation conditions.
Please refer to the installation manual of each indoor unit for details.

3) Cooler room temperature correction

Depending on the installed environment, the room temperature sensor may 
require a correction.
Please refer to the installation manual of each indoor unit for details.

4) Heater room temperature correction

Depending on the installed environment, the room temperature sensor may 
require a correction.  
Please refer to the installation manual of each indoor unit for details.

5) Auto restart

Enable or disable automatic system restart after a power outage. 

( ...  Factory setting)

Setting description 

Function 

number 

Setting  

value 

Yes

40

00

No

01

*  Auto restart is an emergency function such as for power failure etc.  
   Do not start and stop the indoor unit by this function in normal operation.  

  Be sure to operate by the controller, or external input device.

6)  Indoor room temperature sensor switching function

(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote 
controller temperature sensor. 

( ...  Factory setting)

Setting description 

Function 

number 

Setting  

value 

No

42

00

Yes

01

* If setting value is “00” : 
   Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01” :
   Room temperature is controlled by either indoor unit temperature sensor or 

remote controller unit sensor.

The air conditioner signal code is set to A prior to shipment. Contact your 
retailer to change the signal code.

The remote controller resets to signal code A when the batteries in the 
remote controller are replaced. If you use a signal code other than signal 
code A, reset the signal code after replacing the batteries.

If you do not know the air conditioner signal code setting, try each of the 
signal codes (

) until you find the code which operates the air 

conditioner.

STEP 2

SELECTING THE FUNCTION NUMBER AND SETTING VALUE
Refer to the indoor unit installation manual for details on the function  

numbers and setting values.

Selecting the Function Number and Setting Value

1

  Press the SET TEMP. (

) (

) buttons to select the function number.

 

(Press the MODE button to switch between the left and right digits.)

2

  Press the FAN button to proceed to setting the value.

 

(Press the FAN button again to return to the function number selection.)

3

  Press the SET TEMP. (

) (

) buttons to select the setting value.

 

(Press the MODE button to switch between the left and right digits.)

4

  Press the TIMER MODE button, and START/STOP button, in the order 

listed to confirm the settings.

5

  Press the RESET button to cancel the function setting mode.

6

  After completing the FUNCTION SETTING, be sure to turn off the power 

and turn it on again.

10°C HEAT

Function number

Setting value

 

CAUTION

After turning off the power, wait 10 seconds or more before turning on it 
again. The FUNCTION SETTING doesn’t become effective if it doesn’t  
do so.

Function Details

Functions

Function 

number

Slim duct

1)

Filter sign

11

 *1

2)

Static pressure

-

3)

Cooler room temperature 
correction

30

4)

Heater room temperature 
correction

31

5)

Auto restart

40

6)

Indoor room temperature  
sensor switching function

42

7)

Remote controller signal code

44

8)

External input control

46

9)

Room temperature control 
switching

48

*1: It is effective only to install IR Receiver unit.

9378626041-03_IM.indb   5

14/5/2555   9:07:13

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание UTY-LRHYM

Страница 1: ...kά Português Русский Tϋrkçe PART NO 9378626041 03 INSTALLATION MANUAL For authorized service personnel only AIR CONDITIONER IR RECEIVER UNIT UTY LRHYM 9378626041 03_IM indb 1 14 5 2555 9 07 09 AMP Air Conditioning www ampair co uk sales ampair co uk ...

Страница 2: ...fore touching electrical components For the air conditioner to operate satisfactorily install it as outlined in this installation manual Installation work must be performed in accordance with national wiring standards by authorized personnel only Do not cut shorten or extend the cable in the standard parts Do not turn on the power until all installation work is complete CAUTION This mark indicates...

Страница 3: ...al reception angle Indoor unit Ceiling 120 Remote controller Max 10m 5m Receiver unit Signal reception angle 6 INSTALLING THE RECEIVER UNIT CAUTION Do not touch the PCB or PCB parts of receiver unit directly with your hands Fixing of the holder cover with the screws in the standard parts may be unsuitable if the wall or ceiling material is weak If so prepare screws suitable for the wall or ceiling...

Страница 4: ...NECT Tape 6 1 Select the wiring pattern Pattern A From the top of the receiver unit No additional work is necessary Pattern B From behind the receiver unit Perform the following procedure to route the wiring behind the receiver unit 1 2 Holder PCB Holder cover Screw 1 1 Remove the screw 2 Remove holder PCB from holder cover 1 Route the wiring as shown in the figure 2 1 Hook Holder cover Screw 1 Re...

Страница 5: ...each indoor unit for details EXAMPLE Connect the wires and then use heat shrink tubing to protect the connection from dust and water droplets Provide a trap in the receiver unit wiring To prevent water droplets from entering the receiver unit and the connector If the wiring length is 10m replace with receiver unit wire C optional parts Receiver unit wire A 5m CONNECT Receiver unit Heat shrink tubi...

Страница 6: ...ng description Function number Setting value No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature sensor If setting value is 01 Room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor The air conditioner signal code is set to A prior to shipment Contact your retailer to change the signal code The remot...

Страница 7: ...act your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Use the following steps to select the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code 1 Press the START STOP button until only the clock is displayed on the remote controller disp...

Страница 8: ... unit Indoor unit fan motor error 5 3 Indoor unit Water Drain error 5 15 Indoor unit Indoor unit error 6 2 Outdoor unit Outdoor unit main PCB error 6 3 Outdoor unit Inverter PCB error 6 4 Outdoor unit Active filter error PFC circuit error 6 5 Outdoor unit IPM error 6 10 Outdoor unit Display panel error 7 1 Outdoor unit Discharge thermistor error 7 2 Outdoor unit Compressor thermistor error 7 3 Out...