background image

6

Rev. A
920-0081

TSM23S/Q Hardware Manual

1.3  Safety Instructions

Only qualified personnel should transport, assemble, install, operate, or maintain this equipment. 

Properly qualified personnel are persons who are familiar with the transport, assembly, installation, 

operation, and maintenance of motors, and who meet the appropriate qualifications for their jobs. 

To minimize the risk of potential safety problems, all applicable local and national codes regulating 
the installation and operation of equipment should be followed. These codes may vary from area 
to area and it is the responsibility of the operating personnel to determine which codes should be 
followed, and to verify that the equipment, installation, and operation are in compliance with the 
latest revision of these codes.

Equipment damage or serious injury to personnel can result from the failure to follow all applicable 
codes and standards. Applied Motion Products does not guarantee the products described in 
this publication are suitable for a particular application, nor do they assume any responsibility for 
product design, installation, or operation.

• 

Read all available documentation before assembly and operation. Incorrect handling of the 
products referenced in this manual can result in injury and damage to persons and machinery. 
All technical information concerning the installation requirements must be strictly adhered to.

• 

It is vital to ensure that all system components are connected to earth ground. Electrical safety 
is impossible without a low-resistance earth connection.

• 

This product contains electrostatically sensitive components that can be damaged by incorrect 

handling. Follow qualified anti-static procedures before touching the product. 

• 

During operation keep all covers and cabinet doors shut to avoid any hazards that could 
possibly cause severe damage to the product or personal health.

• 

During operation, the product may have components that are live or have hot surfaces. 

• 

Never plug in or unplug the Integrated Motor while the system is live. The possibility of electric 
arcing can cause damage.

Be alert to the potential for personal injury. Follow recommended precautions and safe operating 
practices emphasized with alert symbols. Safety notices in this manual provide important 
information. Read and be familiar with these instructions before attempting installation, operation, 
or maintenance. The purpose of this section is to alert users to the possible safety hazards 
associated with this equipment and the precautions necessary to reduce the risk of personal injury 
and damage to equipment. Failure to observe these precautions could result in serious bodily 

injury, damage to the equipment, or operational difficulty.

Содержание TSM23Q series

Страница 1: ...TSM23S Q Integrated Step Servo Motor Hardware Manual Rev A...

Страница 2: ...M23S Q Communications 14 3 2 1 Connecting to the PC using RS 232 14 3 2 2 Connecting to a Host using RS 485 15 3 3 Inputs and Outputs 17 3 3 1 Connector Pin Diagram 17 3 3 2 STEP DIR Digital Inputs 18...

Страница 3: ...0 0081 TSM23S Q Hardware Manual Model Communications RS 232 RS 485 Modbus RTU TSM23S 2AG TSM23S 2RG TSM23S 3AG TSM23S 3RG TSM23S 4AG TSM23S 4RG TSM23Q 2AG TSM23Q 2RG TSM23Q 3AG TSM23Q 3RG TSM23Q 4AG T...

Страница 4: ...L Commanded Velocity Jogging Position Control Digital Signal type Step Direction CW CCW pulse A B Quadrature Analog Position Serial Commanded Position Q Programming Q Verision only Stand alone operati...

Страница 5: ...rnal Power Supply Voltage Temp Detect Over Current Detect motor encoder 5 Volt DC Power Supply DSP Driver Controller 3 3VDC Internal Logic Supply TSM23S Q I O Connector 5VDC 100mA max GND Status AIN O...

Страница 6: ...n injury and damage to persons and machinery All technical information concerning the installation requirements must be strictly adhered to It is vital to ensure that all system components are connect...

Страница 7: ...nnect the drive to the PC using the programming cable When using RS 485 it must be setup in a 4 Wire configuration see Connecting to a host using RS 485 below Connect the drive to the power supply See...

Страница 8: ...Absolute minimum power supply input is 10 VDC If the Input supply drops below 10 VDC the low voltage alarm will be triggered This will not fault the drive Absolute maximum power supply input is 75 VDC...

Страница 9: ...the less current will be required from the power supply It is important to note that the current draw is significantly different at higher speeds depending on the torque load to the motor Estimating h...

Страница 10: ...que Boost Supply Current Full Load No Load 0 0 5 1 1 5 2 2 5 3 3 5 0 0 5 1 1 5 2 2 5 0 10 20 30 40 50 Torque N m Speed RPS TSM23 3 G 24V Power Amps Continuous Torque Boost Supply Current Full Load No...

Страница 11: ...e Boost Supply Current Full Load No Load 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 0 1 2 3 4 5 0 10 20 30 40 50 Torque N m Speed RPS TSM23 4 G 48V Power Amps Continuous Torque Boost Supply Current Full Load No Lo...

Страница 12: ...Rev A 920 0081 TSM23S Q Hardware Manual 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 0 1 2 3 4 5 0 10 20 30 40 50 Torque N m Speed RPS TSM23 4 G 70V Power Amps Continuous Torque Boost Supply Current Full Load No Lo...

Страница 13: ...fuse on the drive and void the warranty Applied Motion Products offers two matched power supplies for use with the TSM23S Q A 24VDC 150W P N PS150A24 and a 48VDC 320W P N PS320A48 These power supplies...

Страница 14: ...l communication types to a PC 3 2 1 Connecting to the PC using RS 232 Locate the TSM23S Q within 1 5 meters of the PC Plug the DB9 connector of the communication cable that came with the drive into th...

Страница 15: ...d receive wires One pair of wires must connect the host s transmit signals to each drive s RX and RX terminals The other pair connects the drive s TX and TX terminals to the host s receive signals A l...

Страница 16: ...will need to connect individually to the host computer so that it can be assigned a unique address Once the drive has been connected to the PC as described above launch the Step Servo Quick Tuner soft...

Страница 17: ...for the Step Direction function these inputs can be used for CW CCW step start stop direction oscillator mode or general purpose input X3 X4 are low speed software programmable input and can be used...

Страница 18: ...or FS Seek Home SH and other SCL or Q commands The diagrams below show how to connect the STEP DIR Inputs to various commonly used devices 5v to 24v out DIR STEP DIR DIR STEP STEP Indexer with Sinking...

Страница 19: ...ical switches you will need a 5 24 V power supply What is COM Common is an electronics term for an electrical connection to a common voltage Sometimes common means the same thing as ground but not alw...

Страница 20: ...the signal range offset dead band and filter frequency The TSM23S Q provides a 5 volt 100mA limit voltage supply that can be used to power external devices such as potentiometers It is not the most ac...

Страница 21: ...ition dynamic Y3 can be set to control a motor brake These outputs can also be turned on and off by program instructions like Set Output SO The output can be used to drive LEDs relays and the inputs o...

Страница 22: ...t frequency proportional to motor speed tach signal or to provide a timing output 50 pulses rev or to indicate whether the motor is in position static Diagrams of various connection types follow Do no...

Страница 23: ...which warnings may be masked Code Error Solid green no alarm motor disabled Flashing green no alarm motor enabled 1 red 1 green motor stall optional encoder only 2 red 1 green ccw limit 2 red 2 green...

Страница 24: ...continuous 7 5 amp rating is boost 0 0 5 1 1 5 2 2 5 3 3 5 0 10 20 30 40 50 Torque N m Speed rps TSM23 4 G 24V 48V 70V 24V 48V 70V Continuous Boost 0 0 3 0 6 0 9 1 2 1 5 0 10 20 30 40 50 Torque N m S...

Страница 25: ...Q Hardware Manual 5 2 Mechanical Outlines Unit mm Model Length L Length M TSM23S Q 2 G 95 6 24 6 TSM23S Q 3 G 117 6 46 6 TSM23S Q 4 G 120 6 49 9 L 1 20 24 7 5 Flat 8 38 1 M 7 4 5 1 56 4 Max 56 4 Max 4...

Страница 26: ...bandwidth digital noise rejection filter on all inputs X1 X2 Optically isolated 5 24 volt Minimum pulse width 250 ns Maximum pulse frequency 2 MHz Function Pulse Direction CW CCW Pulse A B quadrature...

Страница 27: ...oftware which drive is connected and what the firmware version is There are two types of SCL commands buffered and immediate Buffered commands are loaded into and then executed out of the drive s comm...

Страница 28: ...adjust a drive s serial communications protocol to best fit an application Typically this command is used when configuring a drive and saved as part of the startup parameters But it can be used at any...

Страница 29: ...29 Rev A 920 0081 TSM23S Q Hardware Manual 6 Contacting Applied Motion Products 404 Westridge Dr Watsonville CA 95076 USA 1 800 525 1609 Tel 831 761 6555 Fax 831 761 6544 www applied motion com...

Отзывы: