AST 560 Semi-automatic Cryostat Microtome 

201911119 

---1--- 

1

Safety Notes 

1.1Overview

 

 

The  Operator  Manual  contains  important  safety  instructions  and  information.  In  order  to 

operate the instrument safely, the operator must read carefully prior to starting up the instrument. 
It is very important to ensure safety and avoid instrument damage. Please keep the manual close 
to the instrument to read easily at any time. 

  Note:

  The  safety  marks  and  protective  device  on  both  instrument  and  accessories  may 

neither be removed nor modified , so as not to injure human body or instrument .           

1.2 Safety Warning 

Every principle person should read carefully and carry out strictly according to the following 

safety  notes  relating  to  transport,  installation,  calibration,  operation,  maintenance,  cleaning  and 
all aspects of the instrument. 

1.2.1 Warning during transport and installation 

  The  instrument  may  only  be  transported  or  moved  in  an  upright  position  and  the  tilt 

angle should not exceed 45 

°

.                                                                                             

  Prior to removing the microtome , remove the blade holder .                                                                                                                                                                                                     

  The input voltage has been preset at the factory , please check this setting complies with 

your local power requirement before connecting to the main power                             

  Please  use  the  power  cord  provided  .  If  need  to  replace  it,  please  use  the  power  cord 

with earth wire.                                                                                                             

  Do not operate this instrument in the room with the danger of explosion .               

Don't  remove  or  modify  the  protective  device  on  both  instrument  and  accessories  ,  in 

order to avoid injury to instrument or human body !                                   

1.2.2 Warning of Operation 

  Take care when handling microtome knives and disposable blades . The cutting edge is 

extremely sharp and might cause serious injury.                                                               

  Remove the knife/blade before detaching the blade holder from the instrument , and put 

the blade back into the blade box when not in use                                                           

  Never place the blade with the cutting edge facing upwards and never take out the blade 

with your hands.                                                                                                           

  Please clamp the specimen block before clamping the blade .                                         

  Prior  to  replacing  the  specimen  and  blade  ,  please  lock  the  handwheel  and  cover  the 

blade guard on the cutting edge .                                                                                           

  Rotate the handwheel clockwise, otherwise it would affect section .                         

  Don't  rotate  the  handwheel  clockwise  and  counterclockwise  frequently  at  top  and 

bottom , it might lead to deviation of section thickness .                                                     

  Ensure no liquid enters into interior of instrument during working .                                   

Содержание AST 560

Страница 1: ...AST 560 Semi automatic Cryostat Microtome Operation Manual www amos scientific com AMOS SCIENTIFIC PTY LTD ABN37 159 778 140...

Страница 2: ......

Страница 3: ...Presented in this Operation manual are the structure functions and using notice Reading carefully prior to operating the instrument...

Страница 4: ...ly it is necessary to read the operation manual carefully Our companies are not only responsible for the repair but also train distributors ability of repairing To repair the product smoothly in time...

Страница 5: ...INSTALLATION 6 3 4 ELECTRICAL CONNECTION 7 4 OPERATION 8 4 1 OPERATION PANEL FUNCTION CONTROL 8 4 3 AUXILIARY FUNCTION 10 4 4 CRYO CHAMBER TEMPERATURE SETTING 11 4 5 SPECIMEN CLAMP TEMPERATURE SETTIN...

Страница 6: ...the factory please check this setting complies with your local power requirement before connecting to the main power Please use the power cord provided If need to replace it please use the power cord...

Страница 7: ...cord before changing the fuse Please use the fuse according to the requirement and specification in operation manual 1 3 Safety Device Handwheel locking mechanism As showed in Fig1 it is the lock lev...

Страница 8: ...sing etc which is for the pathological analysis of tissue samples 2 2 Overview Instrument Components The main structure of cryostat microtome is shown in Figure 3 as below 1 Touch Panel 7 Heating glas...

Страница 9: ...on is enabled or disabled Defrosting at fixed time or manually Sterilization at fixed time or manually Sleep at fixed time or manually Large freezing shelf could load 17 samples simultaneously Quickly...

Страница 10: ...wo fixed support feet and make the front wheels disabled Start the instrument after let it rest for at least 2 hours Ensure no other goods around the instrument At least 300mm distance must be kept fo...

Страница 11: ...in order Upholder 2 Corner Support 1 3 Corner Support 2 6 Corner Support 3 7 Corner Support 4 11 Handwheel 8 Blade Holder 9 Cryostat Microtome 12 Glass Support 5 Then take out other accessories in th...

Страница 12: ...check that this setting complies with the local power requirements Connect the instrument to a ground power socket to avoid accident Please use the power cord provided If need to replace it please us...

Страница 13: ...he icon pop up sub interface select the auxiliary function 3 Lamp Click the icon turn on off the lamp 4 Time display and set Display current date and time Click the icon set the date and time 5 Cryo c...

Страница 14: ...number sum Section number sum when exchange between slicing and trimming the value will return to zero automatically 14 Progress display Display the sample clamp progress 15 Section thickness set Acc...

Страница 15: ...ate to continue setting 3 Right arrow Use cooperatively with left arrow 1 select one date and set its working time for each function 4 Automatic defrosting time Set the selected date and set the autom...

Страница 16: ...an 8 click this icon to activate this function It will work for 15 minutes and stop 5Pump waste sweeps Prepare the related tools click on this icon the device automatically pump cutting waste sweeps 6...

Страница 17: ...Value adjustment Double arrows can be adjusted once 5 single arrow can be adjusted 1 3Quick value selection Select temperature value quickly 4Back After setting the parameters click it back to the mai...

Страница 18: ...n click SECT TRIM icon once it turns to retraction mode while TRIM turns to green When the current mode is retraction RETRA is green click RETRA icon once it turns to white while SECT turns to green w...

Страница 19: ...ction status the icon is highlighted or it is dark 6 Heating glass opened When the heating glass is open the icon is highlighted or it is dark 7 Alarm When the device has alarm information the icon is...

Страница 20: ...tion of blade holder and base As showed in fig 17 slide the blade holder along the track in cryo chamber turn the fixed lever 2 to horizon position to lock the blade holder The blade is close to speci...

Страница 21: ...e and put it into box when not in use Fig 17 Adjust the angle As showed on fig 18 the rotating angle is from 0 to 10 degree the user can adjust the angle in this range according to requirement Fig18 F...

Страница 22: ...er 2 Always clamp the specimen before installing the blade to avoid injury Fig 20 Blade inserting As showed in fig 21 loosen the fixed lever 5 and push the blade 6 into blade holder 4 then rotate the...

Страница 23: ...ntion to the following aspects 1 Proper cryo chamber temperature selection 2 Correct section operation 3 careful anti roll plate adjustment 4 Sharp blade and appropriate sectioning angle 5 The blade i...

Страница 24: ...ction To obtain a high quality section it is important to keep cleaning the instrument So the user must clean the instrument periodically or irregularly according to the total sectioning quantity to o...

Страница 25: ...e white tie tightly along the edge to fix firmly Fig 26 Fig 25 Fig 26 Pull off the silica plug of sucking hole as the Fig 27 and properly placed Fig 27 Plug the adaptor with filter bag into the suctio...

Страница 26: ...and then removed the scrap bag to clean the waste scraps or change a new scrap bags to continue work 5 3 Maintenance Fuse replacement Put the fuse 1 in the installation part 2 and then insert the ins...

Страница 27: ...than the blade Adjust the anti roll plate Section soften The temperature of blade or anti roll plate is too high Extend the cooling time of blade or anti roll plate The section sticks to the blade or...

Страница 28: ......

Страница 29: ......

Страница 30: ...Published by AMOS SCIENTIFIC PTY LTD Address 1 Prestige Dr Clayton South VIC 3169 Melbourne Australia Tel 61 4 10190188 Fax 61 3 98081503 Website www amos scientific com Email info amos scientific com...

Отзывы: