6.8 Air fil ter
•
Clean in take port (1).
•
Open cover (2).
•
Open re tain ing clips (3) and re move cover (4).
•
Care fully re move fil ter el e ment (5) from fil ter hous ing (6).
•
Clean fil ter cover (4) and hous ing (6).
•
Check fil ter el e ment (5) for cracks or other dam age by hold ing
against the light or us ing a lamp.
•
Beat the se cu rity el e ment eas ily out.
•
Blow out fil ter el e ment (5) with dry com pressed air (max. 5
bar) from in side to the out side.
•
Note num ber of clean ing cy cles on the fil ter el e ment.
•
Care re fit fil ter el e ment (5).
•
Fit cover (4) and se cure with clips (3).
•
Close cover (2).
6. En gine main te nance
67
Change the fil ter el e ment:
–
if the fil ter el e ment or seal ing ring is dam aged
–
af ter clean ing six times
–
if sooty de pos its are pres ent
–
if moist or oily de pos its are pres ent
–
if en gine per for mance re duces or
–
if the ex haust gas changes col our
–
min i mum once a year
Never op er ate the en gine with out air fil ter el e ment.
The fil ter car tridge and the se cu rity el e ment not
wash out.
The se
cu
rity el
e
ment not blow out with com
-
pressed air.
Danger
Wear safety gog gles – risk of eye in ju ries!
Содержание APH 110-95
Страница 2: ......
Страница 3: ...Originalbetriebsanleitung DE Book ID 2 00002027 APH 110 95 Serial Nr 0000001...
Страница 44: ......
Страница 45: ...Book ID 2 00002027 APH 110 95 Serial Nr 00000001 Translation of the original Operating instructions EN...
Страница 46: ......
Страница 84: ......
Страница 85: ...Traduction du Mode d emploi original FR Book ID 2 00002027 APH 110 95 Serial Nr 0000001...
Страница 86: ......
Страница 124: ......
Страница 125: ...Traducci n del Instrucciones de servicio original ES Book ID 2 00002027 APH 110 95 Serial Nr 0000001...
Страница 126: ......
Страница 164: ......
Страница 165: ......
Страница 166: ...Ammann Verdichtung GmbH Josef Dietzgen Stra e 36 53773 Hennef Phone 49 2242 8802 0 www ammann group com 08 2015...