Interfaces
Version 0.5
AMIMON Confidential
24
The following table specifies the timing parameters -
Table 8: Reset Timing Requirements
Symbol Parameter
Condition
MIN
TYP
MAX
Units
T
RST-CLK
Time from assertion of the HW reset until valid
clock is generated
40 MHz clock is valid –
few us after power up
300
ns
T
ST,RST
Time from assertion of the HW reset until the
STM32F completes the internal initialization
Power is stable
4.5
ms
T
INIT
Time from assertion of the HW/SW reset until the
AMN2210 completes the internal initialization
1.7
ms
The following figure specifies the reset schema and related signals -