AMF² 36K + HMI 08.2013
Page 22 of 71
Make sure that the filter is disconnected from any electrical power source
; carefully open the control panel cabinet and
re-tight the bolts of the terminal strips.
Piston and Piston Housing re-assembly:
1.
Check that the V-Shape Plate of the cartridge points to the central line of the filter, if necessary turns it by hand
accordingly. Insert Piston#40 into the filter body and make sure that that the following three points are met:
i.
The piston is inserted over the Tail Pipe Assembly located in the center line of the filter
(1)
.
ii.
The piston is inserted in the right direction
(2).
iii.
The spray nuzzles are gently inserted in the gaps between the cassette rows
(3)
and are not hitting the
cartridge while the piston is pushed in (you may need assistants to keep the piston balanced while
pushing it into the filter).
Piston#40 Insertion Direction
(2)
This side in
Re-tight the screws
of the terminal strips