background image

 

 

 

 

 

 

Amiad Water Systems - ADI-X IOM                                      910101-001180 / 06.2021 

59 

 

 

 

4.5.1.3.3

 

The Alerts Tab 

Element

 

Description

 

The upper red / grey 

line 

Displays the name of the currently connected controller and the communication 

status (connected / disconnected). 

The second line 

Enables sorting alerts between two dates and resetting an alert.   

The alerts list  

Displays the alert messages according to their occurrence time and date.  

See Appendix B. Alarms and Faults List. 

 
4.5.1.3.4

 

The Reports Tab 

Element

 

Description

 

The upper red / grey 

line 

Displays the name of the currently connected controller and the communication 

status (connected / disconnected). 

The second line 

Displays icons of the different flush types. Select the desired icons to be displayed 

on the chart. 

The chart window 

Displays the number of flush cycles according to the selected icons.  

Total Flushing Cycles  The total number of flush cycles currently displayed in the chart window.  

The lower black line 

Enables the user to select the chart’s time span (day, week, month). 

 
4.5.1.3.5

 

The History Tab 

Element

 

Description

 

The upper red / grey 

line 

Displays the name of the currently connected controller and the communication 

status (connected / disconnected). 

The second line 

Enables sorting events between two dates and deleting an event.   

The black line 

Enables filtering events according to the four flush types (DP, Interval, Manual, 

Preset, Anti Freeze). 

The events list 

Displays the events messages according to their occurrence time and date.  
Flush cause, Flush date, and Flush time is shown in every raw of the list. Click "

" icon to see the following information: 

 

Inlet pressure before the flush 

 

Outlet pressure before the flush 

 

DP pressure before the flush 

 

DP pressure after (the DP measured after flushing. Interval between end of 

flushing and DP measuring is determined by "Ignore DP" parameter). 

 
4.5.1.3.6

 

Settings menu 

Enter the Settings menu by clicking on the " " icon in the upper right corner of any of the 5 tabs. 

This menu contains controller settings. See the list of settings with description in Appendix A. ADI-X 

Controller Settings.  

Click the setting to change it. Click "Save" to save changes. 

 

Содержание ADI-X IOM

Страница 1: ...NOTE This document contains Amiad confidential information Copying and distributing this document are strictly prohibited ...

Страница 2: ...ential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that all users understand ris...

Страница 3: ...4 1 133T 33TADI X Desktop Application Sign Up33T 18 33T4 1 233T 33TADI X Mobile Application Log In33T 22 33T4 1 333T 33TADI BLE Mobile Application Registration33T 23 33T4 233T 33TAdding ADI X Controller to a user accounts33T 25 4 2 1 Adding ADI X Controller using the ADI X Desktop Application 26 4 2 2 Adding ADI X Controller using the ADI X Mobile Application 30 4 2 3 Pairing the ADI X Controller ...

Страница 4: ...Controller Buttons 60 5 2 ADI X Controller Sharing 60 5 3 ADI X Controller Parameters Setting 63 5 4 ADI X Controller Parameters Resetting 66 5 5 ADI X Controller Counters Reset 69 5 6 Manual Flushing 72 5 7 Downloading Reports 75 5 8 Chaining ADI X Controllers 76 33T633T 33TAppendix A ADI X Controller Settings33T 77 33T6 133T 33TThe Basic Settings33T 77 33T6 233T 33TTechnician 33TSettings 78 33T7...

Страница 5: ...ation Sign Up Screen 4U33T 20 33TUFigure 19 ADI X Desktop application Sign Up Screen 5U33T 21 33TUFigure 20 ADI X Desktop application Home pageU33T 21 33TUFigure 21 ADI X mobile application Sign in Screen 1U33T 22 33TUFigure 22 ADI X mobile application Sign in Screen 2U33T 22 33TUFigure 23 ADI BLE mobile application Welcome screen U33T 23 33TUFigure 24 ADI BLE mobile application System units scree...

Страница 6: ...33TUFigure 51 ADI X mobile application Accept invitationU33T 62 33TUFigure 52 ADI X Desktop application Sites screen Settings tabU33T 63 33TUFigure 53 ADI X mobile application Go to Settings menuU33T 64 33TUFigure 54 ADI BLE mobile application Go to Settings menuU33T 65 33TUFigure 55 ADI X Desktop application Sites screen Settings tabU33T 66 33TUFigure 56 ADI X Desktop application Dialog windowsU3...

Страница 7: ... may lead to damage and may affect your warranty coverage Consult with the manufacturer prior to any non standard use of this equipment Do not carry out system cleaning and or maintenance in an explosive atmosphere 1 2 Installation General Install the controller according to the detailed installation instructions provided in this manual or in the Quick Guide provided with the filter or controller ...

Страница 8: ...familiar with its operation instructions Observe the safety stickers on the controller and do not perform any operation other than those given in this manual Do not operate or use the controller for purposes other than its original design The system is for use for non hazardous liquids only Do not carry out system cleaning and or maintenance in an explosive atmosphere 1 5 Before Any Maintenance or...

Страница 9: ...ltration system remotely Supporting both Cloud and Bluetooth wireless technology ADI X allows you to connect to your filter from any mobile device or desktop regardless of your location while on the Cloud 2 2 The ADI X Controller Components Take a few moments to familiarize yourself with the ADI X Controller components Figure 1 ADI X controller components 1 Protection cover 2 LCD display 3 Left co...

Страница 10: ...ontroller is supplied as a part of a filtration system the controller is already installed and connected Figure 2 ADI X controller installed on a Spin Klin Nova Trio Plus system To disassemble the installed controller 1 Disconnect all cables and pipes see 3 3 ADI X Terminal Blocks Connections and 3 4 ADI X DP Sensor Connections 2 Push the controller up to remove it from the bracket Figure 3 Removi...

Страница 11: ...d Instructions 1 Mount the 100x120 mm plate on the pole using clamps minimum dimensions 2 Remove the controller from the bracket see Figure 3 Removing the ADI X controller from the bracket 3 Tighten the bracket to the plate using 4 screws Figure 4 Bracket installation on plate 4 Attach the controller to the bracket Press the controller until you hear click Notice handle with care Plate Bracket ...

Страница 12: ... its bracket see Figure 3 Removing the ADI X controller from the bracket 3 Attach the bracket to the wall Level the bracket by using a water level 4 Mark the location of the bracket holes on the wall see fig below 5 Using a drill install 4 wall anchors in the marked locations Attach the bracket to the wall Tighten the mounting screws into the anchors Figure 5 Bracket installation on wall 5 Attach ...

Страница 13: ...nect external differential pressure switch 5 Pause Used to connect external device to trigger pause 6 Analog inputs Used to connect analog signals 4 20 mA 0 10 V power to input is controlled from sensors of following types pressure temperature conductivity turbidity humidity 7 DS valve Output for downstream valve through solenoid latch 8 V1 V12 outputs For filter flush through solenoid latch 9 Ala...

Страница 14: ...removal Notice the connection cables enter the controller case via silicon insulated holes Once the silicon insulation is broken by the cable it will no longer provide sufficient insulation without cable Do not remove cables from entrance holes without replacing them with the new ones Notice every external device connected to the controller should be correctly set up in controller settings see 5 3...

Страница 15: ...n work with an internal or external DP sensor depending on configuration The controller s default configuration is the internal DP sensor Water pipes should be connected to the DP inlet and outlet See Figure 1 ADI X controller components Figure 9 Internal DP sensor connections Water connection Water connection ...

Страница 16: ...plied loose The estimated batteries lifetime is one year or about 80K flushes whichever comes first To install replace the batteries 1 Remove the top cover by loosening the four screws Figure 10 ADI X controller Top cover removal 2 Remove the two screws that secure the battery cover This will allow access to the battery assembly Figure 11 Battery cover removal ...

Страница 17: ...move the battery assembly from the device and replace 4 x 1 5V Type D batteries Figure 12 Battery assembly with 4 x 1 5V D batteries 4 Reinstall the battery assembly 5 Close battery cover and tighten the screws 6 Reassemble the top cover and tighten the screws ...

Страница 18: ...via the cloud It allows you to operate your controller by remote access 14 ADI BLE Mobile application connects to the controller via Bluetooth wireless technology The mobile device should be within a range of 10 15 meters from the controller This application does not require or support cloud services The free ADI X and ADI BLE mobile applications by Amiad Water Systems are available for download o...

Страница 19: ...lick SEND Figure 14 ADI X Desktop application Sign Up Screen 1 3 A verification code will be sent to your email Log into your email account open the mail and copy your verification code Paste the verification code and click Verify code Figure 15 ADI X Desktop application Sign Up Screen 2 ...

Страница 20: ...ew Password field and reenter the new password in the Confirm New Password field Remember your password Click Create Figure 16 ADI X Desktop application Sign Up Screen 3 5 Enter your Full Name Country Company and Job Description Click Next Figure 17 ADI X Desktop application Sign Up Screen 4 ...

Страница 21: ...101 001180 06 2021 21 6 Select your application language and units METRIC or IMPERIAL Click SUBMIT Figure 18 ADI X Desktop application Sign Up Screen 5 7 Your ADI X user account was created Figure 19 ADI X Desktop application Home page ...

Страница 22: ...our mobile device Log in using Email and password created earlier see 4 1 1 1 Enter your Email used for signing up in ADI X Desktop application Click CONTINUE Figure 20 ADI X mobile application Sign in Screen 1 2 Enter your password created during sign up in ADI X Desktop application Click SUBMIT Figure 21 ADI X mobile application Sign in Screen 2 ...

Страница 23: ...evice To register your account in the ADI BLE application 1 Activate your mobile device s Bluetooth discovery mode and start the ADI BLE application 2 Click OK to start setting up your account Figure 22 ADI BLE mobile application Welcome screen 3 Select your preferred system units Metric or Imperial and click OK Figure 23 ADI BLE mobile application System units screen ...

Страница 24: ... Click SUBMIT To skip this step click SKIP in the upper right corner completing these steps is recommended for better support Figure 24 ADI BLE mobile application Registration screen 5 At this stage your account was successfully created and is ready use Figure 25 ADI BLE mobile application Account creation confirmation ...

Страница 25: ...ccount the owner account The owner can share the ADI X controller with other users see 5 2 ADI X Controller Sharing To add your ADI X controller to your account you need to set the ADI X controller in communication mode and get the specific PIN code displayed by following these instructions 1 Open the ADI X controller display protection cover 2 If needed Press the Left Button to enable LED backlig...

Страница 26: ... ADI X Desktop application 1 Open the ADI X Desktop application Sign in with your email and password 2 Click on the Home page only for the first controller or go to the Sites Manager tab in the left menu and click ADD SITE Figure 27 ADI X Desktop application The first site adding on Home screen Figure 28 ADI X Desktop application New sites adding on Sites manager screen ...

Страница 27: ...code obtained from the controller Click NEXT Figure 29 ADI X Desktop application Controller identification 4 In Site ID window fill in the Name Your Site field select a Filter Model from the list enter filter serial number in Filter Serial Number field add site picture by clicking Add site image Click NEXT Figure 30 ADI X Desktop application Site ID window ...

Страница 28: ...low rate in Flow Rate m3 h field enter working pressure in Working Pressure BAR field select Filtration Degree from the list Click NEXT Figure 31 ADI X Desktop application Site information window 6 In Site Location window set the location of the site on the map Click SUBMIT Figure 32 ADI X Desktop application Site location window ...

Страница 29: ...confirm the payment notice At this stage your controller is connected to your account and ready for use Click Next 8 In Site Added window your ADI X is ready to use Click Continue 9 To view data from your controller select the desired controller from Sites List on Sites page see 4 3 3 2 ...

Страница 30: ... X Mobile Application 1 Open the ADI X Mobile Application Sign in with your email and password 2 Click the in the List of Sites window Figure 33 ADI X mobile application Add site 3 Make sure the controller is turned on and in communication mode Enter the 8 digit PIN code obtained from the controller Click NEXT Figure 34 ADI X mobile application Controller identification ...

Страница 31: ... Serial Number field add site picture by clicking the Site image icon Click NEXT Figure 35 ADI X mobile application Site ID screen 5 In Site Information screen select water source from the list enter flow rate in Flow Rate m3 h field enter working pressure in Working Pressure BAR field select filtration degree from the list Click NEXT Figure 36 ADI X mobile application Site information screen ...

Страница 32: ...ion of the site on the map Click NEXT Figure 37 ADI X mobile application Site location screen 7 In Payment window you should confirm the payment notice At this stage your controller is connected to your account and ready for use Click Next Figure 38 ADI X mobile application Payment Notice screen ...

Страница 33: ...t this stage your controller was connected to your user account and ready for use Click SUBMIT Figure 39 ADI X mobile application Site location screen 9 To view data from your controller select the desired controller from Sites List on Sites screen see 4 4 3 1 ...

Страница 34: ...plications Amiad recommends pairing the ADI X controller with the dedicated ADI X applications Mobile and Desktop To pair the controller with the ADI BLE Mobile Application 1 Verify your mobile device s Bluetooth discovery mode is activated To start pairing with the ADI X controller click in the window The application scans for controllers within the Bluetooth range 10 15 meters Figure 40 ADI BLE ...

Страница 35: ...ntroller from the controllers list in range The application will start pairing Figure 41 ADI BLE mobile application Scan screen 3 Verify that the blue green LED on your controller is blinking Click YES to confirm Figure 422 ADI BLE mobile application Confirm pairing screen ...

Страница 36: ...te enter filter model and controller serial number if needed You may add a site photo by clicking on Add Photo Click Figure 433 ADI BLE mobile application Site ID screen 5 Enter the Site Information details optional Click SUBMIT to add your new filter to the Sites List Figure 444 ADI BLE mobile application Site Information screen ...

Страница 37: ... Systems ADI X IOM 910101 001180 06 2021 37 6 To view data from your controller select the active controller from the Sites List marked by the active Bluetooth icon Figure 455 ADI BLE mobile application Site data ...

Страница 38: ...nitoring Sites Map The Sites Map page contains a map where all owned and linked Sites are marked See 4 3 3 3 Monitoring Alerts The Alerts page contains active alerts from all connected controllers and a list of alert messages according to their occurrence time and date See 4 3 3 4 Settings Sites Manager The Sites Manager page contains a list of all owned and linked Sites and allows adding and dele...

Страница 39: ...sername Shows the Username Drop down menu Username drop down menu contains two options My account opens System settings page See 4 3 3 6 Sign out allows the user to sign out of the account 4 3 3 Page Details 4 3 3 1 Home Dashboard Page Home page is displayed after log in You can return to Home page by clicking Home in the Header line or by clicking on the ADI X logo in the upper left corner The Ho...

Страница 40: ... for the specific controller Click the Alerts icon to open the controller s Alerts tab on Sites page see 4 3 3 2 6 Connection mode The controller connection mode online or offline Last connection Only in offline mode The last time the controller was connected Next connection Only in offline mode The time of next attempt to connect to the controller Last flush DP after Only in offline mode The DP m...

Страница 41: ... Element Description Site name Site name given by site owner Filter type Filter s model controlled by the controller Operation mode Controller operation mode primary or secondary Communication status If the controller is disconnected the status Disconnected will be shown here in red Power mode Power mode is represented by the icon Plug the controller is on AC power Battery the controller is on bat...

Страница 42: ...y the user Flushing Cycles Preset The number of flush cycles started due to the preset start times Flushing Cycles Reset button Click this button to reset the counters to zero excluding total flush counter Reports Data type drop down list The drop down list for selection of data type to be displayed on the chart Reports Period drop down list The drop down list for selection of period for which the...

Страница 43: ...n to select desired list s time span By default last week events are shown Dates selection Enables showing events between two dates Select the desired list s time span Alerts list Display the active alerts or the list of alert messages according to their occurrence time and date Active History tab See Appendix B Alarms and Faults List 4 3 3 2 7 About tab About tab contains the following informatio...

Страница 44: ...Click Active to see the list of active alerts for the specific controller Click History to see the list of alert messages according to their occurrence time and date Time span buttons Available only on History tab Click Day Week Month button to select desired list s time span By default last week events are shown Dates selection Available only on History tab Enables showing events between two date...

Страница 45: ...ontroller to your user account My Sites List List of owned sites Each element of the list contains the following information Site picture Communication status icon Site name Filter type Invite icon click to share the site with other account Edit icon click to edit Site ID information location and manage invitations Delete icon click this icon to delete the site from the account Linked Sites List L...

Страница 46: ...l address you entered while creating an account Cannot be changed Full name User s full name Country Country of operation drop down list Company User s company name Job description User s job description drop down list Preferred language The language of applications drop down list Units selection Units to be used in applications Receive updates from Amiad Check this checkbox to receive updates fro...

Страница 47: ...rt It contains the following elements Element Description Full name Your full name Email Your email Company Your company name Message field Write your message to Amiad support here Send button Click Send to send your message to Amiad support 4 3 3 8 User Manual Page The User manual page contains the link to the digital version of the User Manual ...

Страница 48: ...ew and settings and Add Site button See 4 4 3 1 Monitoring Sites Map The Sites Map screen contains the map where all owned and linked sites are marked as well as Add Site button See 4 4 3 2 Monitoring Alerts The Alerts screen contains active alerts from all connected controllers and a list of alert messages according to their occurrence time and date See 4 4 3 3 Settings Sites Manager The Sites Ma...

Страница 49: ...flushing Interval between end of flushing and DP measuring is determined by Ignore DP parameter see Appendix A ADI X Controller Settings Last received inlet Only in offline mode Last inlet pressure received when connected Last received DP Only in offline mode Last DP received when connected Alerts icon The number on Alerts icon represents the number of active alerts for the specific controller Cli...

Страница 50: ...offline mode The last time the controller was connected Next connection Only in offline mode The time of next attempt to connect to the controller Time from last flush Only in online mode The time since the end of the last flush cycle Last flush cause Only in online mode The trigger that initiated the last flush Pressures Inlet The current reading of the filter s inlet pressure Pressures Outlet Th...

Страница 51: ...messages for selected time span will be displayed in the list Alerts list Display the active alerts or the list of alert messages according to their occurrence time and date Active History tab See Appendix B Alarms and Faults List 4 4 3 1 4 Reports tab Element Description The upper red grey line Displays the name of the site and the communication status connected disconnected The second line Displ...

Страница 52: ...ith description in Appendix A ADI X Controller Settings Click the setting to change it Click Save to save changes 4 4 3 2 Sites Map Screen Sites Map screen displays the map where all owned and linked Sites are marked The Add Site button is located in the upper right corner 4 4 3 3 Alerts Screen The Alerts screen contains active alerts from all connected controllers and a list of alert messages acc...

Страница 53: ...arms and Faults List 4 4 3 4 Sites Manager Screen Sites Manager screen allows adding and deleting sites from the account The Add Site button is located in the upper right corner The Site Manager screen contains the following elements Element Description My Sites List List of owned sites Each element of the list contains the following information Site picture Communication status icon Power mode ic...

Страница 54: ...ons Units selection Units to be used in applications SUBMIT button Click SUBMIT to save any changes 4 4 3 6 Support Screen Support Screen allows sending messages to Amiad support It contains the following elements Element Description Full name Your full name Email Your email Company Your company name Message field Write your message to Amiad support here SUBMIT button Click SUBMIT to send your mes...

Страница 55: ...3 8 Profile Screen Profile screen allows changing account parameters Element Description Full name User s full name Country Country of operation drop down list Company User s company name Job description User s job description drop down list Receive updates from Amiad Check this checkbox to receive updates from Amiad SUBMIT button Click SUBMIT to save any changes done ...

Страница 56: ...screen and Site tabs that are available for each active site See details in the following tables 4 5 1 Screens Details 4 5 1 1 Sites List Screen Element Description Menu button Opens Menu screen see 4 5 1 2 Add new site button Starts pairing process for new site List of paired sites List of all paired sites Clicking on active site will open Site tabs see 4 5 1 3 Each element of the list contains f...

Страница 57: ... or US Language Select the application user interface language English French German Hebrew Italian Spanish Portuguese Chinese Russian or Turkish Messages Messages from the Amiad system Account Displays the registration details of the system User name User email User country User company and User job description User Manual This screen shows the user manual Support Contact Us screen App Version Di...

Страница 58: ... The pressure differential across the filter calculated by subtracting the outlet pressure from the inlet pressure Manual Flushing Click this icon to start a manual flush cycle 4 5 1 3 2 The Counters Tab Element Description The upper red grey line Displays the name of the currently connected controller and the communication status connected disconnected Last reset at The date of the last resetting...

Страница 59: ... to select the chart s time span day week month 4 5 1 3 5 The History Tab Element Description The upper red grey line Displays the name of the currently connected controller and the communication status connected disconnected The second line Enables sorting events between two dates and deleting an event The black line Enables filtering events according to the four flush types DP Interval Manual Pr...

Страница 60: ...t push Turn on display backlight Start manual flush Long push Enter communication mode Force full cloud synchronization 5 2 ADI X Controller Sharing ADI X controller can communicate via cloud with one account only If another account needs access to the controller via cloud communication use the share site function Shared site will be displayed as Linked site in the sites list Linked account has fu...

Страница 61: ...o share your site with Click OK The invitation has been sent Figure 47 ADI X Desktop application Invite window 5 An invitation notification will appear in the Notifications Center Click ACCEPT to accept the invitation The site will appear in the linked sites list Figure 48 ADI X Desktop application Home page accept invitation ...

Страница 62: ... right corner to send a new invitation 4 In the Invite window enter the email address of the user you want to share your site with Click OK The invitation has been sent Figure 49 ADI X mobile application Site sharing 5 In the account you shared with an invitation notification will appear on the Sites Manager screen Click ACCEPT to accept the invitation The site will appear in the list of linked si...

Страница 63: ...filter type and controller Incorrect settings may lead to nonoperational system To set the controller parameters using ADI X Desktop application 1 Open ADI X Desktop application Sign in with your email and password if needed 2 Go to Sites tab in left menu and select the site where you want to set parameters 3 Go to Settings tab Here you can set parameters Figure 51 ADI X Desktop application Sites ...

Страница 64: ... 3 Click to open Settings menu Figure 52 ADI X mobile application Go to Settings menu 4 Click Technician Settings and enter 4 digit code 1234 to access Technician Settings Notice Do not change any of these settings if you are not fully familiar with the specific filtration system filter type and controller Incorrect settings may lead to nonoperational system 5 Make sure to click Save after changin...

Страница 65: ...where you want to set the parameters 3 Click to open Settings menu Figure 53 ADI BLE mobile application Go to Settings menu 4 Click Technician Settings and enter 4 digit code 1234 to access Technician Settings Notice Do not change any of these settings if you are not fully familiar with the specific filtration system filter type and controller Incorrect settings may lead to nonoperational system 5...

Страница 66: ...ng to the filter provided with the controller or according to the customer s initial settings You can perform parameters restoration via ADI X Desktop application ADI X Mobile application and ADI BLE Mobile application To restore parameters using ADI X Desktop application 1 Sign in to ADI X Desktop application 2 Go to Sites tab in the left menu and select the required site 3 Go to Settings tab and...

Страница 67: ...plication 2 On Sites screen select the required site 3 Click to open Settings menu 4 Click Restore to Filter Type Settings or Restore to Factory Settings see options above Figure 56 ADI X mobile application Settings menu 5 Click OK in the dialog window to approve the settings restoration Figure 57 ADI X mobile application Dialog windows ...

Страница 68: ...th range Bluetooth icon is blue 2 Select the required site where you want to restore the parameters 3 Click to open Settings menu 4 Click Restore to Filter Type Settings or Restore to Factory Settings see options above Figure 58 ADI BLE mobile application Settings menu 5 Click OK in the dialog window to approve the settings restoration Figure 59 ADI BLE mobile application Dialog windows ...

Страница 69: ...o the time intervals settings 4 Manual cycles number of flush cycles initiated manually by the user 5 Preset cycles number of flush cycles started due to the preset start times Counters 2 5 can be reset via ADI X Desktop application ADI X Mobile application and ADI BLE Mobile application To reset the counters using ADI X Desktop application 1 Sign in to ADI X Desktop application 2 Go to Sites tab ...

Страница 70: ...ing ADI X Mobile application 1 Sign in to ADI X Mobile Application 2 On Sites screen select the site where you want to reset counters 3 Go to Counters tab 4 Click Reset in the middle of the screen The counters will reset Figure 61 ADI X mobile application Sites screen Counters tab ...

Страница 71: ...obile application 1 Open ADI BLE Mobile Application Verify that the controller is within Bluetooth range Bluetooth icon is blue 2 Select the required site 3 Go to Counters tab 4 Click Reset in the middle of the screen The counters will reset Figure 62 ADI BLE mobile application Counters screen ...

Страница 72: ...y via ADI X Desktop application ADI X Mobile application and ADI BLE Mobile application To initiate manual flushing using the ADI X controller panel 1 Open the ADI X protection cover 2 If needed Press the left button to enable LED backlight 3 Press the right button short press The flushing will start Figure 63 ADI X controller control panel Right button ...

Страница 73: ...flushing 3 On Overview tab click Manual Flushing The flushing will start Figure 64 ADI X Desktop application Sites screen Overview tab To initiate manual flushing using ADI X Mobile application 1 Sign in to ADI X Mobile Application 2 On Sites screen select the site you want to initiate manual flushing 3 On Online Status tab select Manual Flushing The flushing will start Figure 65 ADI X mobile appl...

Страница 74: ...le application 1 Open ADI BLE Mobile Application Verify the controller is within Bluetooth range Bluetooth icon is blue 2 Select the site you want to initiate manual flushing 3 On Online Status tab select Manual Flushing The flushing will start Figure 66 ADI BLE mobile application Online status screen ...

Страница 75: ...uetooth icon is blue 2 Select the site you want to download report for 3 Click to open Settings menu Click Export Data Figure 67 ADI BLE mobile application Export Data 4 ADI BLE Mobile application displays the various options for sending the reports depending on the general communication applications installed on your mobile device Select the preferred application the recipient and send the report...

Страница 76: ... flush settings are set on each secondary controller separately To chain controllers 1 Connect each secondary controller to the primary controller using Ext A and B contacts Figure 68 ADI X controllers chaining 2 Set the primary controller Operation mode to Primary and select the number of the secondary controllers for primary controller settings see 5 3 3 Set the secondary controllers Operation m...

Страница 77: ...Flush Time Allows the user to set the duration of the flush operation Dwell Time If the system operates two or more filters this parameter allows the operator to set the time delay between the flush cycles of the filters Battery Displays the current charge level of the controller s batteries ID only in ADI X Mobile application Allows the user to set the site s picture name and ID parameters such a...

Страница 78: ...ins the system s basic and fundamental settings Notice Do not change any of these settings if you are not fully familiar with the specific filtration system filter type and controller Incorrect settings may lead to nonoperational system Access to the Technician Settings requires a 4 digit code 1234 ...

Страница 79: ...ng due to a momentary high DP High DP Alarm Set the DP level for issuing a High DP Alarm Message System Log Repeated Flushes to Start Fault Mode Set the number of continuous flush cycles so the ADI BLE controller enters Fault Mode Cycle Time for Continuous Set the cycle time for counting a flush cycle as continuous flushing If the time between two flush cycles is shorter than Cycle Time for Contin...

Страница 80: ...Main Line Flush Set the water meter as it is assembled on the main line or on the flush line Unit liter Gallon Default value liter Water Meter 2 Analog Input Analog Input allows connecting external Analog Sensor to ADI X recording the values and comparing with your filter system values events as Pressure Temperature Conductivity Turbidity Humidity Sampling Interval for record Stabilization Time Th...

Страница 81: ... alert Controller exceeded number of consecutive flushes for alerts Check configuration check DP If high perform manual flush with downstream valve closed open the filter for inspection DFU failed Firmware update fail Validate cellular reception and try again Out of range app connection Controller out of range during connection session Get closer to the controller with the mobile device within Blu...

Страница 82: ...epresentative of Amiad 8 This Warranty will not apply to damaged or defective products resulting from or related to i Fire flood power surges or failures or any other catastrophe and or unforeseen occurrence such as but not limited to those for which the Buyer is customarily insured for or any force majeure events ii Fault abuse or negligence of the Buyer iii Intake water not meeting the agreed st...

Страница 83: ...d Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration http amiad com pdf certificates MACHINERY_SAFETY pdf The Bluetooth word mark and logos are registered trademarks owned by the Bluetooth SIG Inc and any use of such marks by Amiad Water Systems is under license Other trademarks and trade names are those of their respective owners ...

Отзывы: