
MODEL 227
OPERATION MANUAL
Doc # 740063 Rev E
SECTION VII - CALIBRATION
7.8
MISCELLANEOUS MAINTENANCE ITEMS
1. BATRAM - The system BATRAM has a life of from 2 to 5 years. The
following describes what happens to the BATRAM settings and functions
when the BATRAM is replaced:
1.
System Hours and Arc Hours - Will reset to 0.
2.
Day/Date information - Will have to be reset.
3.
Last Language used - Will default to English until reset.
4.
Remote Sensor set ups will have to be reset.
5.
Whole or Tenth increments for Amps and Level Time will reset to whole.
6.
Operators Name will clear.
7.
Power Supply Serial Number will clear.
Replacing the BATRAM requires accessing the inside of the M-227. A
complete replacement procedure is available in the M-227 Maintenance
Manual.
2. RS232 COMMUNICATIONS
The M-227 can shut down the RS232 port on it own if it detects
non-intelligent information on it. This can be caused by ambient
light or improper set up. The RS232 port will not be re-activated
until the power has been re-set. If you are having problems with
RS232 communications, re-set the power and try again.
NOTE
Always keep the plastic dust covers on the RS232 port when not in use.
7.12
Содержание 227
Страница 13: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SYSTEM CONFIGURATON 1 7 ...
Страница 22: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E INSTALLATON LOCATONS 3 4 ...
Страница 23: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E AC POWER SET UP 3 5 ...
Страница 24: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E CABLE CONNECTIONS 3 6 ...
Страница 33: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SEQUENCE TIMING CHART 4 7 ...
Страница 34: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E PANEL KEY LOCATIONS 4 8 ...
Страница 49: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E USE OF NEXT PREVIOUS KEYS 5 5 ...
Страница 54: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E STANDARD REMOTE PENDANT 5 10 ...
Страница 86: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SECTION VIII OPTIONS M227 207 CW OR M207 CW INSTALLATION 8 4 ...