4.7
SENSOR 1, 2, 3 FAULTS
The M-227 has 3 separate inputs that the user can define for creating a fault
condition based on some external problem. The most common is connecting a gas
analyzer(s) to the M-227 to detect excessive Oxygen in the I.D. purge of a weld.
The user must make these connections and uses the SET-UP screen (see 5.8) to
define what a fault is for this external input.
4.8
SET-UP FUNCTIONS
The following SET-UP functions provide some customizing and calculating
features to enhance system performance:
1.
CALCULATE
- Calculates TUNGSTEN LENGTH, IPM to RPM
conversions and WELD TIME.
2.
WELD-SELECT
- The M227-RP may select up to 4 pre-determined weld
schedules from memory. This function defines the schedules that are picked.
3.
COOLANT FAULT
- Used to enable or disable Coolant Fault whether or
not a M227/207-CW or M207-CW is connected.
4.
REV
- Used to display the SOFTWARE REVISION of a particular M-227.
Depending on intended use, M-227’s may have different software revisions.
5.
PRINT EMM
- Used to print a copy of the EMM memory.
6.
AMP - TIME
- Used to change the last significant digit of Level Current or
Level Time from whole numbers to tenths (000 to 000.0).
7.
ARC V FLT
- Used to de-activate STUB OUT and HIGH VOLT faults
These faults are usually needed to be turned off for manual welding.
8.
SENSORS
- Activates and defines EXTERNAL Fault inputs (see 5.8).
9.
PRINTER
- Used to select AUTO or MANUAL print mode.
10.
OSC SPEED
- Used to set the speed that the OSC IN Key and OSC OUT
key move the Oscillator Steering.
11.
DATE RESET
- Used to reset the DATE.
12.
AVC JOG SPEED
- Used to set the speed of the AVC JOG UP and AVC
JOG DOWN. Primarily used to refine Touch Start Operation.
13.
OPERATOR I.D.
- Allows the Operator to enter his name or ID number.
Once entered it will be printed on all copies of weld schedules.
14.
POWER SUPPLY SERIAL NUMBER
- Allows entry of Power Supply
Serial #. Once entered it will be printed on all copies of weld schedules.
4.16
Содержание 227
Страница 13: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SYSTEM CONFIGURATON 1 7 ...
Страница 22: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E INSTALLATON LOCATONS 3 4 ...
Страница 23: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E AC POWER SET UP 3 5 ...
Страница 24: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E CABLE CONNECTIONS 3 6 ...
Страница 33: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SEQUENCE TIMING CHART 4 7 ...
Страница 34: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E PANEL KEY LOCATIONS 4 8 ...
Страница 49: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E USE OF NEXT PREVIOUS KEYS 5 5 ...
Страница 54: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E STANDARD REMOTE PENDANT 5 10 ...
Страница 86: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SECTION VIII OPTIONS M227 207 CW OR M207 CW INSTALLATION 8 4 ...