MODEL 227
OPERATION MANUAL
Doc # 740063 Rev E
SECTION V - OPERATION
5.8
REMOTE PENDANT (RP) OPERATION
1. A complete understanding of system operation is needed for proper use of the
RP. All previous sections of this manual and all previous steps of this section
should be read before proceeding with RP operation.
2. The following functions and features are provided by the standard RP:
1. Sequence Start key
2. Sequence Stop key
3. All Stop key
4. Travel Jog CW key
5. Travel jog CCW key
6. Weld/Test Mode key
7. Wire Feed Mode key
8. Wire Feed Jog key
9. Wire Retract Jog key
10. Osc IN Jog key
11. Osc OUT Jog key
12. AVC UP Jog key
13. AVC DOWN Jog key
14. Primary Amp Override key
15. Background Amp Override key
16. Primary Wire Feed Override key
17 Background Wire Feed Override key 18. Arrow Up key
19. Arrow Down key
20. Special Function key
21. Next key
22. Prev key
23. Primary Pulse Time Override key
24. Background Pulse Override key
25. Primary Travel Speed Override key
26. Background Tvl Override key
27. Primary AVC Override key
28. Background AVC Override key
29. Osc Amplitude Override key
30. Excursion Time Override key
31. IN Dwell time Override key
32. OUT Dwell time Override key
33. 8 character digital status display
2. Items 1 to 13 above are duplicates of keys contained on the M-227 panel. They
work exactly the same as the keys on the panel. When the RP is connected
these keys and the identical ones on the M-227 panel are active at the same
times. Pressing either key will perform the function desired .
3. The 8-charter digital display is used to indicate to the operator what particular
mode or area of a weld schedule the system is in.
When the M-227 is first turned ON the RP display will say NO SEQ. This
indicates to the operator that no weld schedule has been selected. When a
schedule is selected the display will show 001 TEST. This indicates that PASS
# 1 of a Weld Schedule has been called up and that the system is in TEST mode.
At other times it may indicate WELD or FLT depending on system status.
NOTE
If the power was turned off while a weld schedule was displayed the
system will power up with that schedule displayed again. The NO SEQ display
applies to power ON when power OFF occurred without a weld schedule
displayed.
5.11
Содержание 227
Страница 13: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SYSTEM CONFIGURATON 1 7 ...
Страница 22: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E INSTALLATON LOCATONS 3 4 ...
Страница 23: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E AC POWER SET UP 3 5 ...
Страница 24: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E CABLE CONNECTIONS 3 6 ...
Страница 33: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SEQUENCE TIMING CHART 4 7 ...
Страница 34: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E PANEL KEY LOCATIONS 4 8 ...
Страница 49: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E USE OF NEXT PREVIOUS KEYS 5 5 ...
Страница 54: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E STANDARD REMOTE PENDANT 5 10 ...
Страница 86: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SECTION VIII OPTIONS M227 207 CW OR M207 CW INSTALLATION 8 4 ...