SECTION VI - PROGRAMMING
6.3
COPY A WELD SCHEDULE
To copy a weld schedule you must start from the STATUS screen and the OPERATE
mode switch must be in the PROGRAM position.
1. Press the PRO key. Then use the appropriate F key to select COPY and then
press the ENTER key.
2. The screen will then ask you what weld schedule number you wish to COPY.
Use the numeric keys, verify and then press the ENTER key. The system will
then ask you what weld schedule number should be for the COPY. Use the
numeric keys, verify and then press the ENTER key.
3. The system will then proceed to COPY the weld schedule. When it is copied
the program screen will appear and MODIFY can be selected to modify the
COPIED weld schedule.
4. If you ask for a weld schedule that does not exist or try to COPY it to and
existing number the system will notify you that it is an INVALID NUMBER
and to press the CE key and try again.
6.4
TRANSFER/RECEIVE WELD SCHEDULE MEMORY
If a user has more than one M-227, it is usually a good idea to keep both libraries
identical. This is done by TRANSFERRING a COPY of the LIBRARY of one
system into the M-227-EMM; then taking the M-227-EMM to another M-227 and
TRANSFERRING a COPY of it into that M-227.
For single-system users it will also be important to have a security copy of the
memory that can be stored separate from the M-227. If something should happen to
the M-227 memory such as component failure, tampering or accidental deletion, the
M-227-EMM copy can then be used to restore the memory in the M-227.
1. The TRANSFER function allows the user to perform the following functions:
1. TRANSFER the ENTIRE LIBRARY from the M-227 to the M-227-EMM.
2. RECEIVE the ENTIRE LIBRARY from the M-277-EMM.
3. RECEIVE an individual weld schedule from the M-227-EMM to the M-227.
2. To perform any of the above, the M-227-EMM must be plugged into the slot
provided on the M-227 upper housing.
3. The TRANSFER function must begin from the STATUS screen and
OPERATE mode switch must be in PROGRAM.
6.5
Содержание 227
Страница 13: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SYSTEM CONFIGURATON 1 7 ...
Страница 22: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E INSTALLATON LOCATONS 3 4 ...
Страница 23: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E AC POWER SET UP 3 5 ...
Страница 24: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E CABLE CONNECTIONS 3 6 ...
Страница 33: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SEQUENCE TIMING CHART 4 7 ...
Страница 34: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E PANEL KEY LOCATIONS 4 8 ...
Страница 49: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E USE OF NEXT PREVIOUS KEYS 5 5 ...
Страница 54: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E STANDARD REMOTE PENDANT 5 10 ...
Страница 86: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SECTION VIII OPTIONS M227 207 CW OR M207 CW INSTALLATION 8 4 ...