D - MACHINE ADJUSTMENT
2 0 . S E T T I N G - U P O F T H E S P R E A D E R S M O V E M E N T
It is necessary to adjust the spreaders so that the left and right spreader is opening and closing equally on
the left and right, without contacting the needle.
Carefully loosen the spreader crosshead set screw , located in the spreader spindle. . It is necessary to
hold the spreader crosshead to protect it against self adjustment by the pressure of the springs. Adjust
the correct position.
Tighten the crosshead set screw .
I M P O R TA N T !
The right and left-hand spreader distances X, from the needle, must be equal.
Needle
Needle
Springs