D - MACHINE ADJUSTMENT
Rotate the right-handwheel until the needle bar reaches the lowest point of the vibrator stroke. After raising
the needle bar 3.5 mm, (0.140"), note the position of the right
looper point to the center line of the
needle.
If the looper point is not to the center line of the needle, loosen the clip screw and move the right-hand
looper half the distance to the needle center line, by this you align the distance of both loopers.
Tighten the screw.
Total distance is 4 mm - move the end of the looper toward
the center of the needle 2 mm (0.079”)
C A U T I O N !
Check both needle bar strokes to ensure both sides are equal distance from the point of
the looper to the needle centerline.
Example:
4 mm
2 mm