BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC100
51
PB BATTERY PROGRAM
This programme is only suitable for charging lead-acid batteries with a nominal voltage of 2 to 20V. Lead-acid batteries
are completely different from NiMH/NiCd batteries. These batteries can only deliver a lower current compared to their
capacity. Consequently, the same limitation applies to the charging process, the optimal charging current can only be
1/10 of the capacity. Pb batteries cannot be used for fast charging. Please follow the instructions of the battery
manufacturer.
CHARGING PB BATTERY
Set the charging current on the left-hand side and the nominal voltage on the
right-hand side. Current range 0.1-10.0A, the voltage should correspond to
that of the battery to be charged. Press the START/ENTER button for more than
3 seconds to start charging.
The real-time charging status is displayed on the screen. Press the
START/ENTER button again to save the set parameter value. Press the BATT
TYPE/STOP button to end the process.
DISCHARGING PB BATTERY
Set the discharge current on the left and the nominal voltage on the right. The
range of the discharge current is 0.1-5.0A, the voltage should match that of
the battery to be discharged. Press the ENTER/START button for more than 3
seconds to start the discharge process.