BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC100
50
This screen shows the real-time status. Press the BATT TYPE/STOP button
once to stop charging.
DISCHARGING LITHIUM BATTERY
The value of the discharge current on the left side must not exceed 1C and the
value on the right side must not be lower than the voltage recommended by
the manufacturer to avoid over discharge. Press the START/ENTER button for
more than 3 seconds to start the discharge process.
This screen shows the number of cells you have set, and the number of cells
recognised by the processor.
R=Number of cells recognised by the charger.
S=Number of cells you set on the previous screen.
If both numbers are identical, you can start charging. If they are not, press the
BATT TYPE /STOP button to return to the previous screen and check the
number of cells in the battery pack again before continuing.
This screen shows the real-time status of the discharge process. You can press
the BATT TYPE/STOP button to stop the discharge process.