BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC100
49
This screen shows the real-time status during charging. Press the BATT
TYPE/STOP button once to stop charging.
STORAGE CONTROL OF LITHIUM BATTERY
This function is for charging/discharging batteries that are not used immediately. This programme is intended for
charging or discharging batteries in a certain storage condition. They are classified by type: 3.80V LiPO, 3.30V LiFe,
3.70V LiIon, and 3. 90V LiHV. The programme starts discharging when the original state of the battery exceeds the
voltage level for storage.
On this screen you can set the current and voltage of the battery pack. By
charging and discharging, the batteries are brought to the voltage level of the
storage condition.
This screen shows the number of cells you have set and the number of cells
recognised by the processor.
R=Number of cells recognised by the charger.
S=Number of cells you set on the previous screen.
If both numbers are identical, you can start charging by pressing the
START/ENTER button. If they are not, press the BATT TYPE/STOP button to
return to the previous screen and check the number of cells in the battery pack
again before continuing.
DEC. INC.
DEC. INC.
- +
- +
Akkutyp
Stopp
Start
Enter
> 3 Sekunden
Start
Enter
Number
of
cells
Elapsed
time
Charge
current
Supplied
capacity
Current
voltage
battery
LP
00757