BEDIENUNGSANLEITUNG / INSTRUCTION MANUAL AMC100
39
STANDARD BATTERY PARAMETERS
LiPo
LiIon
LiFe
LiHV
NiCd
NiMH
Pb
Nominal
Voltage
3,7V/Cell
3,6V/ Cell
3,3V/ Cell
3,8V/ Cell
1,2V/ Cell
1,2V/ Cell
2,0V/ Cell
Max. Charge
Voltage
4,2V/ Cell
4,1V/ Cell
3,6V/ Cell
4,35V/ Cell
1,5V/ Cell
1,5V/ Cell
2,46V/ Cell
Storage
Voltage
3,8V/ Cell
3,7V/ Cell
3,3V/ Cell
3,9V/ Cell
n/a
n/a
n/a
Alowalble
Fast Charge
Ȥ&
Ȥ&
Ȥ&
Ȥ&
1C-2C
1C-2C
Ȥ&
Min.
Discharge
Voltage
3,0-3,3V/ Cell 2,9-3,3V/ Cell 2,6-2,9V/ Cell 3,1-3,4V/ Cell 0,1-1,1V/ Cell 0,1-1,1/ Cell 1,8V/ Cell
Take great care to select the correct voltage for the different battery types. otherwise, the batteries may be damaged.
Incorrect settings can cause the cells to burn or explode.
CHARGING
During the charging process, a certain amount of electrical energy is fed into the battery. The charging quantity results
from multiplying the charging current by the charging time. The maximum permissible charging current varies
depending on the battery type or capacity and can be found in the specifications of the battery manufacturer. Only
batteries that are expressly designated as fast-chargeable may be charged with a higher charging current than the
standard charging current.
Connect the battery to the terminals of the charger: Red is positive and black is negative. Due to the different resistance
of the cable and the plug, the charger cannot detect the resistance of the battery. For the charger to work properly, it is
important that the charging cable should have an appropriate conductor cross-section and high quality, usually gold-
plated plugs are fitted at both ends. Always refer to the battery manufacturer's manual for the charging method. Adhere
to the recommended charging current and charging time. Lithium batteries should be charged strictly according to the
manufacturer's instructions.
Special attention must be paid to the connection of lithium batteries.
Do not attempt to disassemble the battery pack yourself. Please note that lithium batteries can be connected both in
parallel and in series. When connected in parallel, the capacity of the battery pack is multiplied by the individual
!