Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-59
The PONS User V/I Limits menu allows to set the soft-limits for output voltage, current
and power of each channel at power-on of unit. Default value is full scale, refer to
Figure 3-61.
Up-arrow will return to PONS menu screen; Refer Figure 3-54. Home button will return
to HOME MENU screen 2; Refer Figure 3-14.
Figure 3-61: PONS - User V/I Limits Screen
– Channel 1
Figure 3-62: PONS - User V/I Limits Screen
– Channel 2
Figure 3-63: PONS - User V/I Limits Screen
– Channel 3
Entry
Description
Voltage
Sets the power-on default value of voltage user limit in Volt for each
channel. The default is full-scale of each channel.
Current
Sets the power-on default value of output current in Ampere for each
channel. The default is full-scale for each channel.
Power
Sets power-on default value of the output power in watt (W) for each
channel. The default is module power of each channel.
3.4.6.7.5
PONS
– Voltage Ref Mode
Configures power-on Voltage Ref Mode either INT (internal) or EXT (external) or INT