Asterion DC Multioutput ASA Series Operational Manual
M330516-01
5-3
6
MON-RTN
MONITOR
RETURN
Return for Pin 7 and 8.
Pin 3
– PRG-RTN is shorted with Pin 6 – MON-RTN internal to the
power supply.
7
VMON
ANALOG
OUTPUT
Monitor signal for output voltage
Signal return: Pin 6
Range: 0V to 10V corresponds to 0-100% full-scale output.
Output impedance: 100 Ω, typical
Minimum recommended Load: 100kΩ, typical
Maximum Load: 20kΩ
8
IMON
ANALOG
OUTPUT
Monitor signal for output current
Signal return: Pin 6
Range: 0V to 10V corresponds to 0-100% full-scale output.
Output impedance: 100Ω, typical
Minimum recommended Load: 100kΩ, typical
Maximum Load: 20
Ω
Table 5-1: Analog Programming Connector, Designations and Functions
The pinout function mentioned in Table 5-1 is identical for each channel connectors. To program
desired channel corresponding analog channel connector to be utilized.
CAUTION!
Return signal of all the three channels are shorted internal to the power supply.
Applying a voltage potential between the channel return signal of the individual
channels would damage the power supply.
CAUTION!
Analog programming interface signals are isolated from negative output terminal;
Isolation voltage is rated for ±600 V
RMS
maximum; operation of Isolated Analog
Interface signals should be at SELV safety voltage conditions to chassis ground.