Storage

The instrument should be stored in its packaging, in a dry sheltered area. 

The maximum storage temperature is 10 °C (18 °F) higher than the maximum operating temperature.
The minimum storage temperature is 10 °C (18 °F) lower than the minimum operating temperature.
Refer to the Technical Specification for details of the operating temperature limits.

Unpacking

Check all packages for external signs of damage. Check the contents against the packing note.

Lifting Instructions

Where items are too heavy to be lifted manually, use suitably rated lifting equipment. Refer to the 

Technical Specification for weights. All lifting should be carried out in accordance with local and national 

regulations.

Return of Damaged Goods

IMPORTANT If any item has been damaged in transit, this should be reported to the carrier and to the 

supplier immediately. Damage caused in transit is the responsibility of the carrier not the supplier.

DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim. Save 

the packing with the damaged article for inspection by the carrier.

Return of Goods for Repair

If you need to return goods for repair please contact our Customer Service Department for details of the 

correct returns procedure.

Any item returned to AMETEK Land should be adequately packaged to prevent damage during transit.

You must include a written report of the problem together with your own name and contact information, 

address, telephone number, email address etc.

Design and Manufacturing Standards

The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for 

the design, manufacture and on-site servicing of combustion, environmental monitoring and non-contact 

temperature measuring instrumentation.

Registered ISO 9001 Management System approvals apply in the USA.
UK Calibration Laboratory: UKAS 0034.
USA Calibration Laboratory: ANAB Accredited ISO/IEC 17025.
National Accreditation Board for Testing and Calibration Laboratories 

approvals apply in India.

Operation of radio transmitters, telephones or other electrical/electronic devices in close proximity 

to the equipment while the enclosure doors of the instrument or its peripherals are open, may cause 

interference and possible failure where the radiated emissions exceed the EMC directive.

 

The protection provided by this product may be invalidated if alterations or additions are made to the 

structural, electrical, mechanical, pneumatic, software or firmware components of this system. Such 

changes may also invalidate the standard terms of warranty.

Copyright

This manual is provided as an aid to owners of AMETEK Land’s products and contains information 

proprietary to AMETEK Land. This manual may not, in whole or part, be copied, or reproduced without the 

expressed written consent of AMETEK Land.

Содержание NIR-2K

Страница 1: ...NIR 656 NIR 2K Camera i Q U A L I T Y C U S T O M E R S O L U T I O N S NIR 656 NIR 2K INSTALLATION GUIDE PUBLICATION NO 814089 LANGUAGE ENGLISH ISSUE 1 DATE 01 FEBRUARY 2021...

Страница 2: ...sensitive devices Equipment Operation Use of this instrument in a manner not specified by AMETEK Land may be hazardous Read and understand the user documentation supplied before installing and operat...

Страница 3: ...r Repair If you need to return goods for repair please contact our Customer Service Department for details of the correct returns procedure Any item returned to AMETEK Land should be adequately packag...

Страница 4: ...3 Electrical 5 2 4 Image Processing 5 2 5 Standard Accessories 5 3 Installing the Thermal Imager 6 3 1 Fields of View 8 3 2 Thermal Imager installation dimensions 8 4 Electrical Connections 10 4 1 Co...

Страница 5: ...e of following the procedures given in these instructions Safety may be impaired if the system is not used as indicated It is important to check the equipment with which you have been supplied and the...

Страница 6: ...mal Imaging Camera NIR 656 NIR 2K 2 Fig 1 1 AMETEK Land NIR 656 NIR 2K Thermal Imaging Camera Fig 1 2 NIR 656 NIR 2K Thermal Imaging Camera with Air Purge Protection Jacket and Back Cap Air Purge Prot...

Страница 7: ...in the following items NIR 656 NIR 2K Camera fitted with protection cap on the lens It is recommended that the front window protection cap is kept attached until the camera is installed 1 3 Nomenclatu...

Страница 8: ...x 1476 0 43mrad 48 0 14mrad 16 Focus Range 0 3m to infinity manual focus Protection Window Glass low thermal expansion Accuracy 0 5 K of reading 600 to 1000 C 800 to 1400 C or 1 K of reading 1000 to 1...

Страница 9: ...r ON green Camera Temperature Ambient OK green 2 4 Image Processing Software IMAGEPro IMAGEViewer Advanced image processing and control software Workstation PC Workstation optional Interfacing Open Da...

Страница 10: ...Installation Guide Thermal Imaging Camera NIR 656 NIR 2K 6 INSTALLING THE THERMAL IMAGER 3 Fig 3 1 Installation Drawing NIR 656 NIR 2K with TRACO Power Supply...

Страница 11: ...Installation Guide Thermal Imaging Camera NIR 656 NIR 2K 7 Fig 3 2 TRACO Power Supply dimensions Fig 3 3 Installation Drawing NIR 656 NIR 2K with TRACO DIN Rail Mounted Power Supply...

Страница 12: ...nting pad Either hole can be used for direct tripod mounting A swivel ball mounting S4 B is available from Land infrared This mounting accessory enables you to easily adjust the thermal imager s line...

Страница 13: ...NIR 2K 9 Fig 3 6 Protection Jacket and Back Cap installation dimensions Fig 3 4 Location of connection sockets and LEDs on rear face of thermal imager Ethernet connector Power connector Power status L...

Страница 14: ...ermal imager See Fig 3 4 Electrical connection to the thermometer must be made via the pre wired plug and cable The cable is screened The screen is connected to the connector shell and thus to the cam...

Страница 15: ...n AC input connector is to first screw the connector assembly onto the input socket Fig 4 2 3 Grip the rear section of the input connector and unscrew it from the Power Supply Unit Fig 4 3 Fig 4 4 The...

Страница 16: ...do not have a TRACO Power Supply Unit you can use a 24V DC supply to power the NIR 656 NIR 2K Thermal Imager You will need to connect the camera to the power supply via a cable available from AMETEK L...

Страница 17: ...nds The maximum Gig E cable length is 80m Connect the appropriate Gig E lead between the 8 pin M12 Ethernet connector on the rear of the imager body to that on the PC For installations where the image...

Страница 18: ...display an image of the scene within the camera s field of view 5 1 Focusing the thermal imager onto the target If an individual target is to be measured focus the camera onto the object by gripping...

Страница 19: ...onn Standard Temperature 25m Imager to Power Cable with 2x Conn Standard Temperature 50m Imager to Power Cable with 2x Conn Standard Temperature 814611 814612 814613 Power Cables for DIN Rail PSU TRAC...

Страница 20: ...to meet your unique applications Enhancing user skills by providing access to product and application experts AMETEK Land s global service network provides unparalleled after sales services to ensure...

Отзывы: