Installation Guide
Thermal Imaging Camera
NIR-656 / NIR-2K
10
There is a choice of Power Supply Units available:
•
Thermal Imaging PSU Module (UL Approved) - Part Nº 813478
•
Process Imaging Power Supply (TRACO) - Part Nº 805753
•
Process Imaging Power Supply - DIN Rail-mounted (TRACO) - Part Nº 404.156
•
Customer’s own + 24V Power Supply
Depending on your choice of Power Supply, refer to the manufacturer’s user
documentation supplied with your Unit.
The electrical connections for the thermal imager power supply are made via the Digital
data over 1 GBit Ethernet (M12, 8 pin) and the 8 pin Power socket on the rear of the
thermal imager. See Fig. 3-4.
Electrical connection to the thermometer must be made via the pre-wired plug and
cable. The cable is screened. The screen is connected to the connector shell, and thus
to the camera body of the NIR-656 / NIR-2K. The screen must also be grounded at the
power supply. There are cable options available for both length and termination at the
power supply. For details, see Section 6 ‘Spares & Accessories’.
To connect the cable:
1)
Refer to Fig. 3-4. Align the red marker near the lugs of the pre-wired plug with
the red marker above the keyway in the socket on the thermal imager.
2)
Push the plug into the socket.
To disconnect the cable:
1)
Grip the locking sleeve section of the plug.
2)
Pull the plug outwards to release the locking mechanism and disconnect the cable.
ELECTRICAL
CONNECTIONS
4