Time:
Adjust the current time for the
real time clock.
The hours and minutes have
to be adjusted separately, fi rst
the hours, then the minutes.
Time format is 24 hours, e.g.
15:00h = 3 pm
Switch-on difference of
primary loop
Adjust the switch-on differ-
ence
Switch-on difference of
secondary loop
Adjust the switch-on differ-
ence
Switch-off difference
Adjust the switch-off differ-
ence
Target temperature
Adjust the target temperature
Completing the commis-
sioning menu
After the last channel of the
commissioning menu has
been adjusted and confi rmed,
the controller asks for confi r-
mation of the adjustments.
To confi rm the adjustments
made in the commissioning
menu, press button 3
The controller is now ready for operation with typical settings to suit the system layout
The settings made in the commissioning menu can be changed later on in the corresponding adjustment channels. Ad-
ditional functions and options can be individually set by accessing the system adjustment channels.
Display Channels:
COL:
Collector Temperature
Display range: -40 to +482 °F
Shows the current collector temperature.
TST:
Tank temperature
Display range: -40 to +500 °F
Shows the current tank temperature (from tank bottom sensor).
TPRI:
Flow temperature of the pri-
mary loop
Display range -40 to +500 °F
Indicates the current fl ow temperature of the primary loop in
the Solex station.
TSEC:
Flow temperature of the sec-
ondary loop
Display range -40 to +500 °F
Indicates the current fl ow temperature of the secondary loop in
the Solex station.