Care and cleaning of the water heater.

Draining the Water Heater

!

CAUTION: Shut off gas to the water 

heater at the gas control (thermostat) 

gas cock or manual shut-off valve 

before draining water.

!

DANGER: Before manually operating 

the temperature and pressure relief 

valve, make certain no one will be 

exposed to the hot water released by the 

valve. The water drained from the tank 

may be hot enough to present a scald 

hazard and should be directed to a 

suitable drain to prevent injury or 

damage.

Before turning off the cold water supply to 

the water heater, open a hot water faucet 

allowing sufficient cold water into the 

tank to prevent the risk of a scald injury 

while draining the water heater.  Once the 

water in the tank is no longer hot, turn off 

the cold water supply to the water heater.  

Open a hot water faucet or lift the handle 

on the relief valve to admit air to the tank. 
Attach a garden hose to the drain  

valve on the water heater and direct  

the stream of water to a drain. Open  

the valve.

Routine Preventative Maintenance

Properly maintained, your water heater 

will provide years of dependable trouble-

free service. 
It is recommended that a periodic 

inspection of the gas control (thermostat), 

burner, relief valve, internal flue-way and 

venting system should be made by service 

personnel qualified in gas appliance repair.
It is suggested that a routine preventative 

maintenance program be established and 

followed by the user.
Inspect plastic vent pipe.  Make certain 

that all joints are secure and that vent 

pipe supports are all in place.  Check 

the outdoor vent terminal to see that it is 

free of obstructions, and that there is no 

damage nearby casused by condensate.
Inspect dilution air inlet and combustion 

air inlet openings.  Make certain no 

blockage exists.  Clean any lint, dirt or oil 

accumulation that may exist.
At least once a year, lift and release the 

lever handle on the temperature pressure 

relief valve, located near the top of the 

water heater, to make certain the valve 

operates freely. Allow several gallons to 

flush through the discharge line to an open 

drain.
NOTICE: If the temperature and pressure 

relief valve on the water heater discharges 

periodically, this may be due to thermal 

expansion in a closed water system. 

Contact the water supplier or your 

plumbing contractor on how to correct this. 

DO NOT plug the relief valve outlet.

A water heater’s tank can act as a settling 

basin for solids suspended in the water. 

It is therefore not uncommon for hard 

water deposits to accumulate in the bottom 

of the tank.  If allowed to accumulate, 

these solids can cover the gas control 

(thermostat) sensors, causing the sensors to 

operate erratically.  Because accumulated 

solids can prevent the gas control 

(thermostat) sensors from accurately 

reading the water temperature, the water  

at the fixture can be hotter than the gas 

control (thermostat) setting.  It is suggested 

that a few quarts of water be drained from 

the water heater’s tank every month to 

clean the tank of these deposits. 
Rapid closing of faucets or solenoid valves 

in automatic water using appliances can 

cause a banging noise heard in a water 

pipe. Strategically located risers in the 

water pipe system or water hammer 

arresting devices can be used to minimize 

the problem.
The anode rod should be removed from the 

water heater’s tank annually for inspection 

and replaced when more than 6” of core 

wire is exposed at either end of the rod.
Make sure the cold water supply is turned 

off before removing anode rod.
This water heater incorporates a 

combustion shut off device that shuts 

the operation of the water heater down if 

undesirable combustion conditions occur, 

such as the presence of flammable vapors 

or blockage of the combustion air inlet 

openings.  Please contact a Qualified 

Service Technician if this occurs.

DANGER: Before 

manually operating the 

relief valve, make certain 

no one will be exposed to 

the danger of the hot water 

released by the valve. The 

water may be hot enough to 

create a scald hazard. The 

water should be released 

into a suitable drain to 

prevent injury or property 

damage.

 

DANGER:  Failure to 

perform the recommended 

Routine Preventative 

Maintenance can harm the 

proper operation of this 

water heater, which can cause 

carbon monoxide dangers, 

excessive hot water 

temperatures and other 

potentially hazardous 

conditions.

!

DANGER: Hotter water 

increases the potential for Hot 

Water Scalds.

Location of Dilution Air Holes

Содержание PowerVent

Страница 1: ...r This manual also includes a parts list It is very important that all persons who are expected to install operate or adjust this water heater read the instructions carefully so they may understand ho...

Страница 2: ...re on your part can save you time and money over the life of your water heater You ll find many answers to common problems in the Troubleshooting Guide If you review the chart of Troubleshooting Tips...

Страница 3: ...nts paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity of a water h...

Страница 4: ...for Hot Water SCALDS The illustration below details the approximate water temperature for each mark on the Gas Control Thermostat Temperature Dial D A N G E R HOT Water temperature over 125 can cause...

Страница 5: ...LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to look...

Страница 6: ...installation For residential water heaters of a capacity greater than 52 gallons consult the local building jurisdiction for acceptable bracing procedures Have the installer show you the location of t...

Страница 7: ...r heater to ignite until examined by a Qualified Service Technician DO NOT obstruct or block the flammable vapor sensor Rheem Water Heating FVIR certified gas water heaters can be installed on a resid...

Страница 8: ...than one square inch per 4000 Btuh of the total input rating of all the appliances in the enclosure If horizontal ducts are used to communicate with the outdoors each opening must have a minimum net...

Страница 9: ...dition and eliminating the repeated operation of the relief valve Other methods of controlling thermal expansion are also available Contact your installing contractor water supplier or plumbing inspec...

Страница 10: ...cealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fill the Water Heater Make certain that the drain valve i...

Страница 11: ...pe gas shut offs are used they shall be T Handle type Compound used on the threaded joints of the gas piping must be of the type resistant to the action of LP gas Use compound sparingly on male thread...

Страница 12: ...detailed in this manual have been met Carefully inspect the entire venting system for any signs of cracks or fractures particularly at the joints between elbows or other fittings and the straight len...

Страница 13: ...rtical pipe one 1 90 elbow and two 2 feet of horizontal pipe Number of 90 elbows with Vent Number of 45 Elbows Maximum Vent Pipe Length in Feet ft 0 Maximum Altitude See chart on upper left One 1 None...

Страница 14: ...reeze on the exterior wall under the eaves and on surrounding objects Some discoloration to the exterior of the building is to be expected However improper location or installation can result in sever...

Страница 15: ...nal fitting and connect it as shown to the vent pipe on the exterior of the building Complete the rest of the vent pipe installation to the water heater s vent connector fitting on the blower outlet I...

Страница 16: ...the joint with a rag Allow 15 minutes before handling Cure time will vary according to fit temperature and humidity NOTICE Stir the solvent cement frequently while using Use a natural bristle brush or...

Страница 17: ...local codes or in the absence of local codes in accordance with latest edition of the National Electric Code ANSI NFPA No 70 Refer to the figures below for water heater internal wiring NOTE It is not...

Страница 18: ...om the use of such unauthorized devices CAUTION If local codes require the application of an external insulation blanket to this water heater pay careful attention to the following so as not to restri...

Страница 19: ...tion Air holes see diagram to the left DON T remove the Burner Access Door unless absolutely necessary This should only be done by a qualified service technician A new burner access door gasket must b...

Страница 20: ...and free of leaks Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fittings for possible gas l...

Страница 21: ...Heating Installation Spring loaded check valve in heating unit hot water supply line and cold water return line not supplied with water heater NOTE This check valve is incorporated in some heating un...

Страница 22: ...e Set the valve thermostat dial to LOW This appliance has an automatic spark ignition system DO NOT attempt to light the pilot by hand Wait five 5 minutes to clear out any gas If you smell gas stop Fo...

Страница 23: ...ermostat setting to prevent contact with HOT water Water Temperature Setting The temperature of the water in the water heater can be regulated by turning the knob on the front of the gas control therm...

Страница 24: ...ise young children or others who are incapacitated The gas control thermostat is constructed with a built in safety shut off device designed to shut off the gas supply to the burner if the main burner...

Страница 25: ...er flames 8 The blower motor will stay energized for an additional 30 seconds after the control verifies that the burner flame is extinguished in order to clear combustion gases from the water heater...

Страница 26: ...and pressure relief valve on the water heater discharges periodically this may be due to thermal expansion in a closed water system Contact the water supplier or your plumbing contractor on how to cor...

Страница 27: ...d leak testing The burner chamber is a sealed area If the burner access door is removed the burner access door gasket must be replaced For cleaning remove the burner from the water heater A vacuum cle...

Страница 28: ...Gas Caution in the Operating Instructions Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank The anode rod is slowly consumed thereby elimin...

Страница 29: ...Use a water heater size that meets the requirements heater will cause of your needs condensation Yellow flame Scale on top of the burner Contact a qualified service technician to remove scale or soot...

Страница 30: ...ion Shutoff System Contact a qualified service technician tripped Water is too hot The gas control thermostat See the Water Temperature Setting of The Water is set too high Heater section of this manu...

Страница 31: ...open 1 Replace gas valve control Six One Flash three second pause Failed trial for ignition Insufficient gas supply unstable pilot carbon buildup on electrode or wire pilot tube damage 1 Check gas sup...

Страница 32: ...the rating plate Specify type of gas natural or LP as marked on the rating plate Part description as noted below and number of parts desired CAUTION For your safety DO NOT attempt repair of gas piping...

Страница 33: ...arts The kit provides extra speed clips and tamper resistant screws Burner Access Door Assembly Burner Access Door Gasket Burner Pilot Bracket Screws Pilot Bracket Pilot Screw Burner Hex Nuts Pilot Tu...

Страница 34: ...34 Notes...

Страница 35: ...35 Notes...

Страница 36: ...rbon monoxide detec tor with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completi...

Отзывы: