23

Explosion Hazard

Tighten both manifold door screws
securely.
Remove any fiberglass between the door
gasket and combustion chamber.
Replace viewport if glass is missing or
damaged.
Replace two piece wire connector if
missing or removed.
Replace door gasket if damaged.
Failure to do so can result in death,
explosion, or fire.

1.  Check the door gasket for damage or imbedded debris 

prior to installation.

2.  Inspect the viewport for damage and replace as 

required.

3.  Insert the manifold assembly into the burner 

compartment making sure that the tab of the manifold 
tube engages in the slot of the bracket inside the 
combustion chamber (Figure 28B). Note: The tab is 
located at the bottom of the burner on L.P. gas models.

4.  Inspect the door gasket and make sure there is no 

fiberglass insulation between the gasket and the 
combustion chamber.

5.  Replace the two screws which secure the manifold 

assembly door to the combustion chamber. Tighten 
securely. There should be no space between the 
gasket part of the manifold door and combustion 
chamber. 

Do not operate the water heater if the door 

gasket is not sealed.

6.  Reconnect the two wire leads to the thermal switch, 

the manifold tubing, pilot tubing, and thermocouple to 
the thermostat.  Important: DO NOT attempt to disable 
or modify the thermal switch in any way. Do not cross-
thread or apply any thread sealant to these fittings.

Note: L.P. gas systems use reverse 
(left-hand) threads on the manifold tube.    
The thermocouple nut should be started and 
turned all the way in by hand. An additional 
quarter turn with a 7/16” open-end wrench will 
then be sufficient to seat the lockwasher.

7.  Reconnect the igniter wire.
8.  Turn gas supply on at the manual gas shut-off valve, 

and check the gas supply and gas valve for leaks. Test 
the supply connections by brushing on an approved 
noncorrosive leak detection solution. Bubbles forming 
indicate a leak. Correct any leak found.

9.  Follow the lighting instructions on page 17. With the 

water heater lit check for leaks at the manifold and pilot 
connections. Bubbles forming indicate a leak. Correct 
any leak found.

10.  Verify proper operation and then replace the outer door.

Bracket

Figure 28A
Combustion Chamber

Tab

Flame-trap

Door Gasket

Figure 28B

Manifold Assembly

Close-up

Tab

Bracket

Slot

Manifold tube

Close-up inside view of
the combustion chamber.

Piezoelectric Igniter System

The piezoelectric igniter system consists of the igniter 
button, electrode, and wire.  The pilot is ignited by an 
electric spark generated when the igniter button is pressed. 
The spark gap of 0.125 inch is set when the electrode is 
installed at the factory. (See Figure 29). Use only factory 
authorized piezoelectric igniter parts for replacement.

Testing the Igniter System

Turn off the gas to the water heater at the manual gas shut-
off valve. Watch the electrode tip while activating the igniter. 
A visible spark should jump from the electrode. To avoid 
shock, do not touch the burner or any metal part on the 
pilot or pilot assembly. If no spark is visible, check the wire 
connections and make sure the electrode is not broken. 
Replace the igniter if defective. Dirt and rust on the pilot or 
electrode tip can prevent the igniter spark. Wipe clean with 
a damp cloth and dry completely. Rust can be removed 
from the electrode tip and metal surfaces by lightly sanding 
with an emery cloth or fine grit sandpaper.

Figure 29
Natural Gas & L.P. Gas 
Igniter Assemblies

Igniter

Button

Pilot

Bracket

Pilot

Thermocouple

Electrode

Wire

to

electrode

Tip

.125 *

Snap-on Connector

Electrode

Thermocouple

Tip

Pilot

.125 *

Natural Gas

L.P. Gas

Pilot

Bracket

* Note: Spark gap distance measured from electrode tip to pilot.

Replacing the Manifold Assembly

Содержание 6510381

Страница 1: ...med by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal...

Страница 2: ...as been under water Immediately call a qualified service technician Water heaters subjected to flood conditions or anytime the gas controls main burner or pilot have been submerged in water require re...

Страница 3: ...y personnel a licensed plumber or an authorized service person Important This water heater has a resettable thermal switch installed as part of the Flame Guard Safety System DO NOT attempt to disable...

Страница 4: ...led or leaked in the area of the water heater leave the area immediately and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been exti...

Страница 5: ...stible materials are stated on the data plate adjacent to the gas control valve thermostat of the water heater The water heater is certified for installation on a combustible floor Important If instal...

Страница 6: ...f the water heater as shown The drip leg must be no less than three inches long for the accumulation of dirt foreign material and water droplets Figure 3 Gas Piping Manual Gas Shut off Valve Ground Jo...

Страница 7: ...areas Combustion air must be free of acid forming chemicals such as sulfur fluorine and chlorine These elements are found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint a...

Страница 8: ...an be drawn from outside of the enclosure One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure as shown in Figure 4 The size of each opening free ar...

Страница 9: ...supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may require larger openings to achieve the...

Страница 10: ...n existing water heater be sure to use the new drafthood supplied with the water heater Figure 9 Drafthood Installation Sheet Metal Screws four provided Drafthood Jacket top Install the drafthood with...

Страница 11: ...erms of its listing It must be connected to the water heater s drafthood by a certified vent connector or by directly originating at the drafthood opening Vertical gas vents must terminate with a list...

Страница 12: ...ine as shown in Figure 14 These valves reduce the point of use temperature of the water by mixing cold and hot water and are readily available for use 4 If installing the water heater in a closed wate...

Страница 13: ...s DO NOT add any chemicals to the system piping which will contaminate the potable water supply Closed System Thermal Expansion Periodic discharge of the temperature and pressure relief valve may be d...

Страница 14: ...higher than the working pressure shown on the data plate of the water heater The Discharge Line Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in th...

Страница 15: ...the system Otherwise these bubbles will be trapped in the air handler heat exchanger coil reducing the efficiency Do not connect the water heater to any system or components previously used with non...

Страница 16: ...reduce the likelihood of a flammable vapor ignition incident New technology used in meeting these standards makes this product less tolerant of installation errors or improper installation environmen...

Страница 17: ...with the igniter repeat steps 4 7 Continue to hold the button for about 1 minute after the pilot is lit Release the reset button and it will pop back up Pilot should remain lit If the pilot light goe...

Страница 18: ...r Temperature Regulation UNITROL BEFORE LIG HTIN G READ ALL IN STRUCTIO NS CAUTIO N H O T W A R M V A C A T I O N CAUTION W A TER INCREAS E S HOTTER T H E RISK OF SCALD INJ U R Y V A C A T I O N WAR M...

Страница 19: ...rt on page 26 Reset the thermal switch by depressing the small button in the center of the thermal thermal switch Important Correct any issues prior to resetting the thermal switch DO NOT attempt to d...

Страница 20: ...age or deterioration in the venting system Make sure the ventilation and combustion air supplies are not obstructed Build up of soot and carbon on the main burner and pilot burner Check for a soft blu...

Страница 21: ...to see if it is dirty or clogged The burner may be cleaned with soap and hot water Figure 24 N O T W A H S T R E B O R I A C A V M R A W U T O H T H E R I SK OF Y R U J N I D L A C S R E T T O H W A...

Страница 22: ...ly Page 23 Figure 25 Two Piece Wire Connector Assembly Two Piece Wire Connector Thermocouple Retainer Clip Manifold Door Other fittings not shown for clarity Pilot T ube Igniter Wire Figure 26 Thermoc...

Страница 23: ...lve for leaks Test the supply connections by brushing on an approved noncorrosive leak detection solution Bubbles forming indicate a leak Correct any leak found 9 Follow the lighting instructions on p...

Страница 24: ...ant The gas control valve thermostat is a standard valve with wire leads that connect to a thermal switch Removing the Gas Valve 1 On the gas control valve thermostat turn the temperature dial counter...

Страница 25: ...te heater 7 Correct piping dip tube must be in cold inlet 8 Advise customer DRIP FROM RELIEF VALVE 1 Excessive water pressure 2 Heater stacking 3 Closed water system 1 Use a pressure reducing valve an...

Страница 26: ...nstructions section of this manual for specific requirements NO Is the pilot tube damaged NO Does the flame trap show signs of discoloration and or debris Shut off the gas supply to the water heater a...

Страница 27: ...y System parts Item No Parts Description 1 DRAFTHOOD 2 REDUCER RING SOME MODELS 3 FLUE BAFFLE 4 HEAT TRAP COLD SOME MODELS 5 HEAT TRAP HOT SOME MODELS 6 COLD WATER DIP TUBE 7 ANODE ROD 8 TEMPERATURE P...

Страница 28: ...e wire connector with retainer clip thermal switch and pilot assembly Natural Gas Low Nox Item 17 Manifold door assembly which contains the manifold tube gasket door pilot tube thermocouple two piece...

Отзывы: