Replacing the Thermocouple

1.  Remove the manifold assembly as directed previously.

2.  Remove the retainer clip from the back of the two piece 

wire connector and remove the two piece wire connector 
from the manifold door (Figure 25).

3.  Pull the thermocouple from the pilot assembly (Figure 

29).

Be careful not to bend or alter the position of the pilot 
assembly components.

4.  Push the new thermocouple through the holes in the 

pilot bracket. Insert the thermocouple tube into the holes 
provided in the pilot assembly until it clicks into place.

5.  Position the new thermocouple through the larger 

opening of the two piece wire connector (Figure 25). Be 
sure igniter wire is positioned through the small opening 
of the two piece wire connector.

6.  See “Replacing the Manifold Assembly” Page 23.

Figure 25
Two Piece Wire
Connector
Assembly

Two Piece

Wire Connector

Thermocouple

Retainer Clip

Manifold

Door

Other fittings
not shown
for clarity

Pilot T ube

Igniter Wire

Figure 26
Thermocouple
Assembly

Mirror

Mirror

Flashlight

Figure 27
Flame-trap visual inspection

External Inspection & Cleaning of the 
Flame-trap

Although not likely to occur, if debris collects on the flame-
trap, use a vacuum, compressed air, or a soft bristle brush 
to remove it.  Note: If unable to inspect or clean the flame 
trap from underneath, follow the “Cleaning the Combustion 
Chamber and Flame-trap” instructions.

Cleaning the Combustion Chamber and 
Flame-trap

1.  Follow procedure outlined in “Removing the Manifold 

Assembly”.

2.  Use a vacuum cleaner/shop vac to remove all loose 

debris in the combustion chamber (Figure 28A). Use 
compressed air to clear any dust or debris that may 
have accumulated in the flame-trap.

3.  Reassemble following the procedure under “Replacing 

the Manifold Assembly”.

Содержание 6510381

Страница 1: ...med by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal...

Страница 2: ...as been under water Immediately call a qualified service technician Water heaters subjected to flood conditions or anytime the gas controls main burner or pilot have been submerged in water require re...

Страница 3: ...y personnel a licensed plumber or an authorized service person Important This water heater has a resettable thermal switch installed as part of the Flame Guard Safety System DO NOT attempt to disable...

Страница 4: ...led or leaked in the area of the water heater leave the area immediately and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been exti...

Страница 5: ...stible materials are stated on the data plate adjacent to the gas control valve thermostat of the water heater The water heater is certified for installation on a combustible floor Important If instal...

Страница 6: ...f the water heater as shown The drip leg must be no less than three inches long for the accumulation of dirt foreign material and water droplets Figure 3 Gas Piping Manual Gas Shut off Valve Ground Jo...

Страница 7: ...areas Combustion air must be free of acid forming chemicals such as sulfur fluorine and chlorine These elements are found in aerosol sprays detergents bleaches cleaning solvents air fresheners paint a...

Страница 8: ...an be drawn from outside of the enclosure One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure as shown in Figure 4 The size of each opening free ar...

Страница 9: ...supply openings consideration must be given to the blocking effect of protection louvers grilles and screens These devices can reduce airflow which in turn may require larger openings to achieve the...

Страница 10: ...n existing water heater be sure to use the new drafthood supplied with the water heater Figure 9 Drafthood Installation Sheet Metal Screws four provided Drafthood Jacket top Install the drafthood with...

Страница 11: ...erms of its listing It must be connected to the water heater s drafthood by a certified vent connector or by directly originating at the drafthood opening Vertical gas vents must terminate with a list...

Страница 12: ...ine as shown in Figure 14 These valves reduce the point of use temperature of the water by mixing cold and hot water and are readily available for use 4 If installing the water heater in a closed wate...

Страница 13: ...s DO NOT add any chemicals to the system piping which will contaminate the potable water supply Closed System Thermal Expansion Periodic discharge of the temperature and pressure relief valve may be d...

Страница 14: ...higher than the working pressure shown on the data plate of the water heater The Discharge Line Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in th...

Страница 15: ...the system Otherwise these bubbles will be trapped in the air handler heat exchanger coil reducing the efficiency Do not connect the water heater to any system or components previously used with non...

Страница 16: ...reduce the likelihood of a flammable vapor ignition incident New technology used in meeting these standards makes this product less tolerant of installation errors or improper installation environmen...

Страница 17: ...with the igniter repeat steps 4 7 Continue to hold the button for about 1 minute after the pilot is lit Release the reset button and it will pop back up Pilot should remain lit If the pilot light goe...

Страница 18: ...r Temperature Regulation UNITROL BEFORE LIG HTIN G READ ALL IN STRUCTIO NS CAUTIO N H O T W A R M V A C A T I O N CAUTION W A TER INCREAS E S HOTTER T H E RISK OF SCALD INJ U R Y V A C A T I O N WAR M...

Страница 19: ...rt on page 26 Reset the thermal switch by depressing the small button in the center of the thermal thermal switch Important Correct any issues prior to resetting the thermal switch DO NOT attempt to d...

Страница 20: ...age or deterioration in the venting system Make sure the ventilation and combustion air supplies are not obstructed Build up of soot and carbon on the main burner and pilot burner Check for a soft blu...

Страница 21: ...to see if it is dirty or clogged The burner may be cleaned with soap and hot water Figure 24 N O T W A H S T R E B O R I A C A V M R A W U T O H T H E R I SK OF Y R U J N I D L A C S R E T T O H W A...

Страница 22: ...ly Page 23 Figure 25 Two Piece Wire Connector Assembly Two Piece Wire Connector Thermocouple Retainer Clip Manifold Door Other fittings not shown for clarity Pilot T ube Igniter Wire Figure 26 Thermoc...

Страница 23: ...lve for leaks Test the supply connections by brushing on an approved noncorrosive leak detection solution Bubbles forming indicate a leak Correct any leak found 9 Follow the lighting instructions on p...

Страница 24: ...ant The gas control valve thermostat is a standard valve with wire leads that connect to a thermal switch Removing the Gas Valve 1 On the gas control valve thermostat turn the temperature dial counter...

Страница 25: ...te heater 7 Correct piping dip tube must be in cold inlet 8 Advise customer DRIP FROM RELIEF VALVE 1 Excessive water pressure 2 Heater stacking 3 Closed water system 1 Use a pressure reducing valve an...

Страница 26: ...nstructions section of this manual for specific requirements NO Is the pilot tube damaged NO Does the flame trap show signs of discoloration and or debris Shut off the gas supply to the water heater a...

Страница 27: ...y System parts Item No Parts Description 1 DRAFTHOOD 2 REDUCER RING SOME MODELS 3 FLUE BAFFLE 4 HEAT TRAP COLD SOME MODELS 5 HEAT TRAP HOT SOME MODELS 6 COLD WATER DIP TUBE 7 ANODE ROD 8 TEMPERATURE P...

Страница 28: ...e wire connector with retainer clip thermal switch and pilot assembly Natural Gas Low Nox Item 17 Manifold door assembly which contains the manifold tube gasket door pilot tube thermocouple two piece...

Отзывы: