background image

5

© American Time

D

e

scr

ip

tio

n

In

st

a

lla

tion

O

p

e

rat

io

n

Co
d

e

 B

lue

M

ai

n

te

n

a

n

ce

A

pp
e

n

d

ix

S

pe
c

ific

at

io

n

s

Wireless Digital Clocks Owner's Manual

5

© American Time

D

e

scr

ip

tio

n

In

st

a

lla

tion

O

p

e

rat

io

n

Co
d

e

 B

lue

M

ai

n

te

n

a

n

ce

A

pp
e

n

d

ix

S

pe
c

ific

at

io

n

s

Wireless Digital Clocks Owner's Manual

Specifications

GENERAL
Dimensions:

Digital Clocks: ............................................................2.5" display: 4 & 6 digit - 12.250” x 5.1875” x 2.5”d
 

          ............................................................4" display: 4 digit - 12.250” x 6.8750” x 2.5”d

 

          ............................................................4" display: 6 digit - 17.250” x 6.8750” x 2.5”d

ATSTCS: Timer Control Station:  ................................4.63”h X 4.56”w X 1.25”deep

Weight: 

Digital Clocks: ............................................................Varies by model

ATSTCS: Timer Control Station:  ................................0.27 lb.

ELECTRICAL
Power Requirements (Digital Clock/Timer only):

Line Voltage:  ..............................................................120vac 50/60Hz -SQD461RS

A

E and SQD461RS

P

E

 

 .............................................................24vac 50/60Hz - SQD461RS

B

E

 

 .............................................................220vac 50/60Hz - SQD461RS

K

E

 Note:

 Voltage is set at factory. See above part number suffix for reference.

Battery: .......................................................................Non-rechargeable coin-cell battery
Maximum Current (Digital Clock/Timer only):  ...........120vac - 130mA (max), 101mA (avg)
Memory Retention on Loss of Line Voltage: ..............Up to 10 years from coin-cell battery
Distance of ATSTCS from Digital Clock/Timer: .........30-ft maximum with 22 AWG stranded wire with minimum 
1/32" thick insulation
Clock Circuits:  ...........................................................3.0mA. max. @ 24vac/120vac
Code Blue Circuits: ....................................................3.0mA. max. @ 12vac/vdc-30vac/vdc
Power Consumption:  .................................................Varies by model

ENVIRONMENTAL

Ambient Operating Range: ........................................32˚F to 104˚F (0˚ to 40˚C)
Recommended Storage Temperature:.......................-30°C to 45°C (-22°F to 113°F) for six months maximum
Humidity: ....................................................................0%-95% non-condensing

OPERATION

Modes Available: ..............................12 hour or 24-hour wireless synchronized
 

 ..............................Incrementing timer with programmable preset value and start/stop capability

 

 ..............................Decrementing timer with programmable preset value and start/stop capability

 

 ..............................Code Blue incrementing timer

Accuracy:  ........................................±1 second to SiteSync IQ system controller
Indications: .......................................Digital Clock/Timer hours and minutes – 4" and 2.5", bright red or green, 
seven segment LED’s hours and minutes are separated by a colon seconds
 

 ........................................ATSTCS Control Station – 2 second audible alarm

Reception: ........................................Colons flash

Содержание SiteSynq IQ

Страница 1: ...Installation and Operation Manual Part H005112 Rev 1 January 2020 Wireless Digital Clocks with Optional Calendar and Elapsed Time Indicator Code Blue...

Страница 2: ...nsitive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of this unit it is required that electrostati...

Страница 3: ...tions 5 Description 6 SQA461RSxE Digital Clock Timer 6 ATSTCS Control Station 6 Installation Instructions 7 SQA461RSxE Installation Instructions 7 Operation 8 13 Digital Clock Operation 8 Timer Contro...

Страница 4: ...urther information be desired or should particular problems arise which are not covered sufficiently the matter should be referred to the Installer or Original Purchaser listed below INSTALLER INFORMA...

Страница 5: ...urrent Digital Clock Timer only 120vac 130mA max 101mA avg Memory Retention on Loss of Line Voltage Up to 10 years from coin cell battery Distance of ATSTCS from Digital Clock Timer 30 ft maximum with...

Страница 6: ...ed and reset Both timer modes have a programmable preset value When the timer reaches the preset value a two second audible alarm sounds from the ATSTCS control panel The Code Blue up counting elapsed...

Страница 7: ...ched electrical circuit wiring using UL approved wire nuts Route field wiring away from sharp projections and corners 5 Join the wall and clock Molex together 6 Seat the bracket spring in the channel...

Страница 8: ...the system controller or by the push buttons on top of the clock see Setting 12 or 24 Hr Mode on pg 11 The ATSTCS timer control station will allow the user to set a 12 or 24 hour mode and time when t...

Страница 9: ...will occur at 00 00 00 Set the UP DOWN CLOCK switch to the DOWN position Set the SET RUN switch to the SET position The hours digits will be flashing Using the INCREMENT switch set the desired hours...

Страница 10: ...en complete press SET RUN The buttons on the digital clock can be used for display setting options and connection information Top of Clock SET RUN OK B I6 LV 3 12HR LV 2 24HR LV 1 CANC CANC AUTO Scrol...

Страница 11: ...the software version of the clock Press OK Button CALE DIA6 DATE T DUR DATE 1 00 00 Scrolling CALENDAR Scrolling DATE DURAT ION Scrolling T DURAT ION Scrolling DATE DISPLAY Press OK Button Press OK Bu...

Страница 12: ...L Scrolling EVENt CAPCOdE Scrolling Test 88 88 88 Scrolling Date Time 01 08 20 Displays RSSI value strength of signal Displays last digits of Master MAC address Displays channel frequency of Master Di...

Страница 13: ...ervals The time and date can be set to display at intervals ranging from 1 to 60 seconds under the DATE DURAT ION and T DURAT ION settings under CALENDAR in the clock menu see page 13 Calendar clocks...

Страница 14: ...ctions is being displayed the Code Blue input will cause the clock to begin counting up elapsed time from 00 00 00 The Code Blue timer can be stopped and the time held for viewing by pressing the STAR...

Страница 15: ...re resetting the Digital Clock Timer back to normal operation but must be opened before another Code Blue can occur The transition from no voltage to applied voltage across the K2 and K2 terminals ini...

Страница 16: ...only that amount of backup capacity This phenomenon is called memory effect The Ni Cad battery s memory can be erased by deeply discharging the battery and recharging it It is recommended that the ope...

Страница 17: ...ommended minimum interconnecting field wire size is 22 8 AWG stranded wire Ensure that installation conforms to the National Electrical Code and local wiring codes CAUTION Electric Shock Hazard Ensure...

Страница 18: ...r to operate Up Clock Down Switch Up Position This position is used to choose up counting elapsed timer mode Clock Position This position is used to choose clock mode Down Position This position is us...

Страница 19: ...Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows DONE Place SET RUN switch in RUN position To Use as a Clock To Use UP Counter To Use DOWN Counter Place SET RUN...

Отзывы: