Wireless Digital Clocks Owner's Manual

Digital Clock Operation

Powering Up

Apply power to the digital clock. The firmware version number will appear for a few seconds, followed by all digits 

illuminated. It will then scroll a digit pattern while it looks for the correct time from the SiteSync IQ system controller. 

Once the receiver inside the clock gets a signal, the clock will begin keeping time. At first startup, the clock may display 

a time such as 1:00:00 until it receives the first time update from the SiteSync IQ system controller. This should only 

take a few seconds, after which the correct time from the SiteSync IQ system controller should appear.

Setting Time

Setting of the time is not needed for the digital clock or timer control station. The time information is automatically 

updated by the SiteSync IQ system controller. The 12- or 24-hour mode option can be configured by the display 

settings of the system controller, or by the push buttons on top of the clock (see 

Setting 12 or 24 Hr Mode

 on pg 11).

The ATSTCS timer control station will allow the user to set a 12- or 24-hour mode and time when the 

SET/RUN

 switch 

is in the 

SET

 position. However, the time and the 12- or 24-hour format will be overridden by the SiteSync IQ system 

controller when it updates the time. Set the S

ET/RUN

 switch to the 

RUN

 position and the 

UP/DOWN/CLOCK

 switch 

to the 

CLOCK

 position to return the clock display.

Setting the Up Counter Preset Time 

(optional)

If you want to use the alarm and hold feature with the 

UP

 timer, you will need to set a preset time for the UP timer.

Set the 

UP/DOWN/CLOCK

 switch to the 

UP

 position. 

Set the 

SET/RUN

 switch to the 

SET

 position. The hours digits will be flashing. 

Using the 

INCREMENT

 switch, set the desired hours for the preset time, then press 

ENTER

. The minutes digits will 

now be flashing. 
Set the desired minutes the same way, then press 

ENTER

. The seconds digits will then be flashing. 

Set the desired seconds the same way, then press 

ENTER

. The display will then flash 

donE

Set the 

SET/RUN

 switch back to the 

RUN

 position.

n

 

Note: 

A preset of 

00:00:00

 allows the digital clock/timer to be used as a standard elapsed timer with a maximum  

elapsed time of 

30:59:59

.

Содержание SiteSynq IQ

Страница 1: ...Installation and Operation Manual Part H005112 Rev 1 January 2020 Wireless Digital Clocks with Optional Calendar and Elapsed Time Indicator Code Blue...

Страница 2: ...nsitive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of this unit it is required that electrostati...

Страница 3: ...tions 5 Description 6 SQA461RSxE Digital Clock Timer 6 ATSTCS Control Station 6 Installation Instructions 7 SQA461RSxE Installation Instructions 7 Operation 8 13 Digital Clock Operation 8 Timer Contro...

Страница 4: ...urther information be desired or should particular problems arise which are not covered sufficiently the matter should be referred to the Installer or Original Purchaser listed below INSTALLER INFORMA...

Страница 5: ...urrent Digital Clock Timer only 120vac 130mA max 101mA avg Memory Retention on Loss of Line Voltage Up to 10 years from coin cell battery Distance of ATSTCS from Digital Clock Timer 30 ft maximum with...

Страница 6: ...ed and reset Both timer modes have a programmable preset value When the timer reaches the preset value a two second audible alarm sounds from the ATSTCS control panel The Code Blue up counting elapsed...

Страница 7: ...ched electrical circuit wiring using UL approved wire nuts Route field wiring away from sharp projections and corners 5 Join the wall and clock Molex together 6 Seat the bracket spring in the channel...

Страница 8: ...the system controller or by the push buttons on top of the clock see Setting 12 or 24 Hr Mode on pg 11 The ATSTCS timer control station will allow the user to set a 12 or 24 hour mode and time when t...

Страница 9: ...will occur at 00 00 00 Set the UP DOWN CLOCK switch to the DOWN position Set the SET RUN switch to the SET position The hours digits will be flashing Using the INCREMENT switch set the desired hours...

Страница 10: ...en complete press SET RUN The buttons on the digital clock can be used for display setting options and connection information Top of Clock SET RUN OK B I6 LV 3 12HR LV 2 24HR LV 1 CANC CANC AUTO Scrol...

Страница 11: ...the software version of the clock Press OK Button CALE DIA6 DATE T DUR DATE 1 00 00 Scrolling CALENDAR Scrolling DATE DURAT ION Scrolling T DURAT ION Scrolling DATE DISPLAY Press OK Button Press OK Bu...

Страница 12: ...L Scrolling EVENt CAPCOdE Scrolling Test 88 88 88 Scrolling Date Time 01 08 20 Displays RSSI value strength of signal Displays last digits of Master MAC address Displays channel frequency of Master Di...

Страница 13: ...ervals The time and date can be set to display at intervals ranging from 1 to 60 seconds under the DATE DURAT ION and T DURAT ION settings under CALENDAR in the clock menu see page 13 Calendar clocks...

Страница 14: ...ctions is being displayed the Code Blue input will cause the clock to begin counting up elapsed time from 00 00 00 The Code Blue timer can be stopped and the time held for viewing by pressing the STAR...

Страница 15: ...re resetting the Digital Clock Timer back to normal operation but must be opened before another Code Blue can occur The transition from no voltage to applied voltage across the K2 and K2 terminals ini...

Страница 16: ...only that amount of backup capacity This phenomenon is called memory effect The Ni Cad battery s memory can be erased by deeply discharging the battery and recharging it It is recommended that the ope...

Страница 17: ...ommended minimum interconnecting field wire size is 22 8 AWG stranded wire Ensure that installation conforms to the National Electrical Code and local wiring codes CAUTION Electric Shock Hazard Ensure...

Страница 18: ...r to operate Up Clock Down Switch Up Position This position is used to choose up counting elapsed timer mode Clock Position This position is used to choose clock mode Down Position This position is us...

Страница 19: ...Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows DONE Place SET RUN switch in RUN position To Use as a Clock To Use UP Counter To Use DOWN Counter Place SET RUN...

Отзывы: