Optional Code Blue Function

Important Considerations

The ATSTCS must be in the RUN mode for Code Blue to override.

The 12vac/vdc to 30vac/vdc signal that starts the Code Blue timer originates from equipment external to the Digital 

Clock/Timer. The external equipment usually employs a switch device (i.e., a relay contact) to apply this signal. That 

switching device is often referred to as the Code Blue contact.

The Code Blue contact does not have to open before resetting the Digital Clock/Timer back to normal operation, but 

must be opened before another Code Blue can occur. The transition from no voltage to applied voltage (across the 

K2+ and K2- terminals) initiates a Code Blue.

If the Code Blue contact opens and closes again before the Digital Clock/Timer is reset back to normal operation, the 

Code Blue timer will start over from 

00:00:00

.

If a power failure occurs during any Code Blue event, the Code Blue timer will start over from 

00:00:00

.

System Maintenance

The Digital Clock/Timer and ATSTCS Control Station have been manufactured for years of dependable, reliable 

use. However, to assure the reliability of this product, it is recommended that the Digital Clock/Timer be 

tested at 

least every six (6) months

 with the Control Station and Code Blue contact for operation in accordance with wiring 

configurations used.

Содержание SiteSynq IQ

Страница 1: ...Installation and Operation Manual Part H005112 Rev 1 January 2020 Wireless Digital Clocks with Optional Calendar and Elapsed Time Indicator Code Blue...

Страница 2: ...nsitive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of this unit it is required that electrostati...

Страница 3: ...tions 5 Description 6 SQA461RSxE Digital Clock Timer 6 ATSTCS Control Station 6 Installation Instructions 7 SQA461RSxE Installation Instructions 7 Operation 8 13 Digital Clock Operation 8 Timer Contro...

Страница 4: ...urther information be desired or should particular problems arise which are not covered sufficiently the matter should be referred to the Installer or Original Purchaser listed below INSTALLER INFORMA...

Страница 5: ...urrent Digital Clock Timer only 120vac 130mA max 101mA avg Memory Retention on Loss of Line Voltage Up to 10 years from coin cell battery Distance of ATSTCS from Digital Clock Timer 30 ft maximum with...

Страница 6: ...ed and reset Both timer modes have a programmable preset value When the timer reaches the preset value a two second audible alarm sounds from the ATSTCS control panel The Code Blue up counting elapsed...

Страница 7: ...ched electrical circuit wiring using UL approved wire nuts Route field wiring away from sharp projections and corners 5 Join the wall and clock Molex together 6 Seat the bracket spring in the channel...

Страница 8: ...the system controller or by the push buttons on top of the clock see Setting 12 or 24 Hr Mode on pg 11 The ATSTCS timer control station will allow the user to set a 12 or 24 hour mode and time when t...

Страница 9: ...will occur at 00 00 00 Set the UP DOWN CLOCK switch to the DOWN position Set the SET RUN switch to the SET position The hours digits will be flashing Using the INCREMENT switch set the desired hours...

Страница 10: ...en complete press SET RUN The buttons on the digital clock can be used for display setting options and connection information Top of Clock SET RUN OK B I6 LV 3 12HR LV 2 24HR LV 1 CANC CANC AUTO Scrol...

Страница 11: ...the software version of the clock Press OK Button CALE DIA6 DATE T DUR DATE 1 00 00 Scrolling CALENDAR Scrolling DATE DURAT ION Scrolling T DURAT ION Scrolling DATE DISPLAY Press OK Button Press OK Bu...

Страница 12: ...L Scrolling EVENt CAPCOdE Scrolling Test 88 88 88 Scrolling Date Time 01 08 20 Displays RSSI value strength of signal Displays last digits of Master MAC address Displays channel frequency of Master Di...

Страница 13: ...ervals The time and date can be set to display at intervals ranging from 1 to 60 seconds under the DATE DURAT ION and T DURAT ION settings under CALENDAR in the clock menu see page 13 Calendar clocks...

Страница 14: ...ctions is being displayed the Code Blue input will cause the clock to begin counting up elapsed time from 00 00 00 The Code Blue timer can be stopped and the time held for viewing by pressing the STAR...

Страница 15: ...re resetting the Digital Clock Timer back to normal operation but must be opened before another Code Blue can occur The transition from no voltage to applied voltage across the K2 and K2 terminals ini...

Страница 16: ...only that amount of backup capacity This phenomenon is called memory effect The Ni Cad battery s memory can be erased by deeply discharging the battery and recharging it It is recommended that the ope...

Страница 17: ...ommended minimum interconnecting field wire size is 22 8 AWG stranded wire Ensure that installation conforms to the National Electrical Code and local wiring codes CAUTION Electric Shock Hazard Ensure...

Страница 18: ...r to operate Up Clock Down Switch Up Position This position is used to choose up counting elapsed timer mode Clock Position This position is used to choose clock mode Down Position This position is us...

Страница 19: ...Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows DONE Place SET RUN switch in RUN position To Use as a Clock To Use UP Counter To Use DOWN Counter Place SET RUN...