background image

Important: Turn off power to outlet or electrical box.

FOR PLUG-IN VERSION;
1.

 Connect PLUG-IN AC POWER SUPPLY 

(2)

 to one end 

    of the SINGLE AC ADAPTER 

(6)

.

2.

 Connect SENSOR CABLE 

(4)

 to the other end of the

    SINGLE AC ADAPTER 

(6)

.

3.

 Connect PLUG-IN AC POWER SUPPLY 

(2)

 to wall outlet.

FOR HARD-WIRED VERSION; 
1.

 Connect 10' EXTENSION CABLE 

(1)

 to HARD-WIRED

    AC TRANSFORMER

 (3)

.

2.

 Connect SENSOR CABLE 

(4)

 to the other end of the 

    10' EXTENSION CABLE 

(1)

.

3.

 Make Black and White power line connections to 

    HARD-WIRED AC TRANSFORMER 

(3)

 and mount 

    on ELECTRICAL BOX 

(5)

.

Fig. 2

4

Unit #1

(Already Installed)

Fig. 3

Unit #2

Unit #3

Unit #4

1

2

4

3

MAXIMUM OF 15 UNITS PER TRANSFORMER.

10' MAXIMUM CABLE LENGTH BETWEEN UNITS.

    MULTI-AC VERSION (DAISY-CHAIN); Fig. 3

Important: 

 Disconnect the first unit’s Y-Adapter from power supply before making daisy-chain connections.

         Note:

 For Unit #1 electrical instructions, refer to section B (page 3).

                    For subsequent Units, refer to instructions below...

C

1.

 Connect one end of the 10' EXTENSION 

(1)

 to the available terminal of the previous unit’s Y-ADAPTER 

(2)

, and

    the other end to the single terminal of the current unit’s Y-ADAPTER 

(3)

.

2.

 Connect SENSOR CABLE 

(4)

 to either of the two available terminals of Y-ADAPTER 

(3)

.

3. 

Repeat Steps above for each additional Unit, for a Max. of 15 Units on one AC POWER SUPPLY. 

 

M965654 Rev. 2.2 (12/17)

    AC VERSIONS (HARD-WIRED / 
PLUG-IN POWER SUPPLY) ; Fig. 2 

B

CAUTION:

  Use only American Standard supplied 

transformers and cable sets. Using non-AS 
supplied cables, or cutting, splicing or modifying 
any components will void the warranty.

Do not connect power to transformer 
until installation of faucet is complete.
Recommended Electrical Box or Equivalent 
by others 4” (102mm) SQ. X 2-1/2” (64mm) 
DEEP 2-GANG ELECTRICAL BOX Appleton 
#4SD1 OR EQUAL (BY OTHERS).

BLACK & WHITE
POWER
CONNECTIONS

Fig. 2

6

4

2

3

5

1

1

WALL
OUTLET 

4" CONTROL BOX
OR EQUIVALENT BY
OTHERS (6)

BLACK & WHITE
POWER
CONNECTIONS

10' EXTENSION

Содержание SELECTRONIC 705X.105

Страница 1: ...americas com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC Integrated Faucet with Above...

Страница 2: ...below deck User adjustable above deck mixing uses ceramic disc valve for dependability long life Mixing handle can be removed for one time temperature setting during installation Installation Instruct...

Страница 3: ...through hole in ESCUTCHEON with PUTTY PLATE 2 and mounting surface Make sure PIN 6 is in back 3 Assemble RUBBER WASHER 7 BRASS WASHER 8 and THREADED LOCKNUT 9 onto SHANK 4 from underside of sink or mo...

Страница 4: ...enter lines as shown 4 Place the BRACKET 5 on the horizontal center line and mark the location of the mounting holes to be drilled 5 Using 1 4 diameter drill bit drill two mounting holes aproximately...

Страница 5: ...structions refer to section B page 3 For subsequent Units refer to instructions below C 1 Connect one end of the 10 EXTENSION 1 to the available terminal of the previous unit s Y ADAPTER 2 and the oth...

Страница 6: ...LINE FILTER 3 on each wall supply outlet Be sure that INLINE FILTER 3 is inserted in the correct direction See Illustration 3 Connect HOT FLEXIBLE SUPPLY marked with red stripe 1 to INLINE FILTER 3 on...

Страница 7: ...tion and hold in place until the LED begins to blink again Fig 4a 5 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection d...

Страница 8: ...a 2 5mm HEX WRENCH Remove SENSOR ASSEMBLY 2 from FAUCET SPOUT 3 Remove O RING 5 Remove SENSOR 2a from CARRIER 4 and replace with new SENSOR 2a Replace O RING 5 Install SENSOR ASSEMBLY 2 into FAUCET SP...

Страница 9: ...hten See Fig 2 in this section CLEAN FILTER SCREEN ON SOLENOIDVALVE Fig 8 9 D 1 Remove the FAUCET SPOUT 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET SPOUT...

Страница 10: ...not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has the flow rate of the faucet reduced significantly A The filter assembly flow regulator or areator...

Страница 11: ...FUNCTION 1 1 2 2 YES YES NO NO YES NO OPEN EXTERNAL SUPPLY STOPS CRITICALLY LOW BATTERY INSTALL NEW BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLA...