SPOUT ASSEMBLY INSTALLATION;
Fig. 1
TOOLS REQUIRED; Fig. 2
Fig. 2
1
2.5 mm Hex Wrench
(Included)
2
Adjustable Wrench
3
Plumbers' Putty or Caulking
4
Phillips Screwdriver
5
Tape Measure
1
2
3
4
5
10'
Fig. 1
457mm
(18)
3/8" COMPRESSION
CONNECTORS
CLEARANCE
25mm (min) - 127mm (max)
(1" min - 5" max)
165mm
(6-1/2)
28mm (1-1/8)
66mm
( 2-5/8)
38mm
(1-1/2 )
140mm
(5-1/2)
191mm
(7-1/2)
191mm
(7-1/2)
MOUNTING
SURFACE
FINISHED WALL
OR BACKSPLASH
Roughing-in Dimensions
2
Turn off hot and cold water supplies before beginning
1
Fig. 1
10
6
PUTTY
(If required)
MOUNTING
SURFACE
(OPTIONAL)
TIGHTEN
SPIN NUTS
1.
Make sure O-RING
(1)
is installed in spout base. If installing
ESCUTCHEON
(2)
(optional): Apply a bead of putty to
bottom edge of ESCUTCHEON PUTTY PLATE
(2)
.
IMPORTANT:
Do not use putty when installing faucet
without escutcheon.
2.
Insert supply HOSES
(3)
, SHANK
(4)
and SENSOR CABLE
(5)
(if equipped) through hole in ESCUTCHEON with PUTTY
PLATE
(2)
and mounting surface.
(Make sure PIN (6) is in back)
.
3.
Assemble RUBBER WASHER
(7)
, BRASS WASHER
(8)
and THREADED LOCKNUT
(9)
onto SHANK
(4)
from
underside of sink or mounting surface. Hand tighten
LOCKNUT
(9).
4.
Use a screwdriver to tighten SCREWS
(10)
on LOCKNUT
(9)
. Work your way around LOCKNUT
(9)
, tightening the
screws slightly each time until all are snug to ensure
even pressure.
CAUTION
Note: All plumbing and electrical wiring must be installed
in accordance with applicable codes, regulations and
standards.
RECOMENDED CONTROL BOX OR
EQUIVALENT BY OTHERS
HARD-WIRED AND MULTI AC 10' MAX. CABLE LENGTH
4
"
(102mm) SQ. X 3-1/2
"
(89mm) DEEP CONTROL BOX
Hubbel-RACO #256
OR EQUAL (BY OTHERS).
INSTALLATION
2
1
4
3
7
8
9
5
I
MPORTANT:
Do not
use putty when installing
faucet without escutcheon.
I
MPORTANT:
Do not
use sealent on threads
CAUTION:
Use only American Standard supplied transformers and
cable sets. Using non-AS supplied cables, or cutting, splicing or
modifying any components will void the warranty.
M965654 Rev. 2.2 (12/17)