background image

9

GENERAL CLEANING; Fig. 13

G

1. 

Remove the FAUCET SPOUT 

(1)

 by unthreading the 

    LEVER SCREW 

(2)

 and pulling off the LEVER 

    HANDLE 

(3)

. Unthread the FAUCET SPOUT 

    SCREW 

(4)

 at the back of the FAUCET. Pull FAUCET 

    SPOUT 

(1)

 up and off. See 

Fig. 2 

in this section.    

2. 

Replace LEVER HANDLE and rotate 

    counter-clockwise to its stop position (100% cold). 
    Remove HANDLE.

3.

 Pull out LIMITER STOP 

(1)

 from the VALVE STEM 

(2)

4.

 Rotate LIMITER STOP 

(1)

 180 degrees and insert 

    back onto VALVE STEM 

(2)

.

5. 

Replace FAUCET SPOUT 

(1)

 and LEVER HANDLE 

    

(3)

. Install LEVER HANDLE SCREW 

(2)

, FAUCET 

    SPOUT SCREW 

(4)

 and tighten. See 

Fig. 2 

in this 

    section.    

     CHANGE HOT LIMIT SETTING
FROM 95% TO 85%; Fig. 12

F

3

9

8

1

2

ROTATE 180

˚

SLOT

SLOT

Fig. 12

Fig. 13

FAQ'S 

Q: 

How will I know if the battery needs to be replaced?

A: 

Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days.

Q: 

Why has the flow rate of the faucet reduced significantly?

A:

  The filter assembly, flow regulator or areator/spray may be clogged. Check and clean. Refer to Start-up/Maintenance, 

 

sections C, D and E.

Q: 

Why doesn’t the water flow out of faucet when I'm within the sensor detection zone?

A:

  Battery may need replacement. Check. If sensor continuously blinks 2 times interrupted by pause, replace battery 

 

or call (844) CRT-TEAM / (844) 278-8326.

Q: 

 What is the normal operating pressure range?

A:

  Faucet will operate with supply pressures ranging from 20-80 psi. 

CAUTION

1. 

Only use a damp, soft cloth to clean the spout and 

 the 

sensor.

2.

 For tougher dirt, use a soft cloth with diluted dish  

 

  washing detergent. Wipe the area using a wet cloth 
  and dry using a soft cloth.

Do not scratch the sensor when cleaning.
Avoid using any abrasives or harsh detergents 
or chemicals.

 

M965654 Rev. 2.2 (12/17)

Содержание SELECTRONIC 705X.105

Страница 1: ...americas com For Parts Service Warranty or other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC Integrated Faucet with Above...

Страница 2: ...below deck User adjustable above deck mixing uses ceramic disc valve for dependability long life Mixing handle can be removed for one time temperature setting during installation Installation Instruct...

Страница 3: ...through hole in ESCUTCHEON with PUTTY PLATE 2 and mounting surface Make sure PIN 6 is in back 3 Assemble RUBBER WASHER 7 BRASS WASHER 8 and THREADED LOCKNUT 9 onto SHANK 4 from underside of sink or mo...

Страница 4: ...enter lines as shown 4 Place the BRACKET 5 on the horizontal center line and mark the location of the mounting holes to be drilled 5 Using 1 4 diameter drill bit drill two mounting holes aproximately...

Страница 5: ...structions refer to section B page 3 For subsequent Units refer to instructions below C 1 Connect one end of the 10 EXTENSION 1 to the available terminal of the previous unit s Y ADAPTER 2 and the oth...

Страница 6: ...LINE FILTER 3 on each wall supply outlet Be sure that INLINE FILTER 3 is inserted in the correct direction See Illustration 3 Connect HOT FLEXIBLE SUPPLY marked with red stripe 1 to INLINE FILTER 3 on...

Страница 7: ...tion and hold in place until the LED begins to blink again Fig 4a 5 Once the SENSOR CONTROL LED 2 begins to blink again remove your hand from the detection zone When the flashing stops the detection d...

Страница 8: ...a 2 5mm HEX WRENCH Remove SENSOR ASSEMBLY 2 from FAUCET SPOUT 3 Remove O RING 5 Remove SENSOR 2a from CARRIER 4 and replace with new SENSOR 2a Replace O RING 5 Install SENSOR ASSEMBLY 2 into FAUCET SP...

Страница 9: ...hten See Fig 2 in this section CLEAN FILTER SCREEN ON SOLENOIDVALVE Fig 8 9 D 1 Remove the FAUCET SPOUT 1 by unthreading the LEVER SCREW 2 and pulling off the LEVER HANDLE 3 Unthread the FAUCET SPOUT...

Страница 10: ...not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days Q Why has the flow rate of the faucet reduced significantly A The filter assembly flow regulator or areator...

Страница 11: ...FUNCTION 1 1 2 2 YES YES NO NO YES NO OPEN EXTERNAL SUPPLY STOPS CRITICALLY LOW BATTERY INSTALL NEW BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLA...