9
GENERAL CLEANING; Fig. 13
G
1.
Remove the FAUCET SPOUT
(1)
by unthreading the
LEVER SCREW
(2)
and pulling off the LEVER
HANDLE
(3)
. Unthread the FAUCET SPOUT
SCREW
(4)
at the back of the FAUCET. Pull FAUCET
SPOUT
(1)
up and off. See
Fig. 2
in this section.
2.
Replace LEVER HANDLE and rotate
counter-clockwise to its stop position (100% cold).
Remove HANDLE.
3.
Pull out LIMITER STOP
(1)
from the VALVE STEM
(2)
.
4.
Rotate LIMITER STOP
(1)
180 degrees and insert
back onto VALVE STEM
(2)
.
5.
Replace FAUCET SPOUT
(1)
and LEVER HANDLE
(3)
. Install LEVER HANDLE SCREW
(2)
, FAUCET
SPOUT SCREW
(4)
and tighten. See
Fig. 2
in this
section.
CHANGE HOT LIMIT SETTING
FROM 95% TO 85%; Fig. 12
F
3
9
8
1
2
ROTATE 180
˚
SLOT
SLOT
Fig. 12
Fig. 13
FAQ'S
Q:
How will I know if the battery needs to be replaced?
A:
Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days.
Q:
Why has the flow rate of the faucet reduced significantly?
A:
The filter assembly, flow regulator or areator/spray may be clogged. Check and clean. Refer to Start-up/Maintenance,
sections C, D and E.
Q:
Why doesn’t the water flow out of faucet when I'm within the sensor detection zone?
A:
Battery may need replacement. Check. If sensor continuously blinks 2 times interrupted by pause, replace battery
or call (844) CRT-TEAM / (844) 278-8326.
Q:
What is the normal operating pressure range?
A:
Faucet will operate with supply pressures ranging from 20-80 psi.
CAUTION
1.
Only use a damp, soft cloth to clean the spout and
the
sensor.
2.
For tougher dirt, use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using any abrasives or harsh detergents
or chemicals.
M965654 Rev. 2.2 (12/17)